341 related articles for article (PubMed ID: 17502694)
21. [An investigation of the bio-tribological performance of diamond-like carbon/ultrahigh molecular weight polyethylene couple].
Jiang SW; Yin GF; Zheng CQ; Zhang L; Meng YG
Space Med Med Eng (Beijing); 2001 Aug; 14(4):282-5. PubMed ID: 11681343
[TBL] [Abstract][Full Text] [Related]
22. Preliminary study of interfacial shear strength between PMMA precoated UHMWPE acetabular cup and PMMA bone cement.
Park KD; Kim J; Yang SJ; Yao A; Park JB
J Biomed Mater Res B Appl Biomater; 2003 May; 65(2):272-9. PubMed ID: 12687720
[TBL] [Abstract][Full Text] [Related]
23. Investigation of interfacial strength and its structure on the development of a new design of UHMWPE acetabular component.
Park K; Park J
J Biomed Mater Res; 2002; 63(3):363-72. PubMed ID: 12115770
[TBL] [Abstract][Full Text] [Related]
24. Surface and chemical properties of surface-modified UHMWPE powder and mechanical and thermal properties of it impregnated PMMA bone cement, III: effect of various ratios of initiator/inhibitor on the surface modification of UHMWPE powder.
Yang DH; Yoon GH; Kim SH; Rhee JM; Kim YS; Khang G
J Biomater Sci Polym Ed; 2005; 16(9):1121-38. PubMed ID: 16231603
[TBL] [Abstract][Full Text] [Related]
25. Engineering analysis of diamond-like carbon coated polymeric materials for biomedical applications.
Alanazi A; Nojiri C; Kido T; Noguchi T; Ohgoe Y; Matsuda T; Hirakuri K; Funakubo A; Sakai K; Fukui Y
Artif Organs; 2000 Aug; 24(8):624-7. PubMed ID: 10971249
[TBL] [Abstract][Full Text] [Related]
26. Characterization and tribology of PEG-like coatings on UHMWPE for total hip replacements.
Kane SR; Ashby PD; Pruitt LA
J Biomed Mater Res A; 2010 Mar; 92(4):1500-9. PubMed ID: 19425047
[TBL] [Abstract][Full Text] [Related]
27. Bone bonding strength of sputtered hydroxyapatite films subjected to a low temperature hydrothermal treatment.
Ozeki K; Mishima A; Yuhta T; Fukui Y; Aoki H
Biomed Mater Eng; 2003; 13(4):451-63. PubMed ID: 14646059
[TBL] [Abstract][Full Text] [Related]
28. Tribological characterization of zirconia coatings deposited on Ti6Al4V components for orthopedic applications.
Berni M; Lopomo N; Marchiori G; Gambardella A; Boi M; Bianchi M; Visani A; Pavan P; Russo A; Marcacci M
Mater Sci Eng C Mater Biol Appl; 2016 May; 62():643-55. PubMed ID: 26952468
[TBL] [Abstract][Full Text] [Related]
29. The effect of IPN surface modification on the mechanical properties of UHMWPE.
Zhang M; James SP; Rentfrow E
Biomed Sci Instrum; 2001; 37():7-12. PubMed ID: 11347448
[TBL] [Abstract][Full Text] [Related]
30. [Viability of murine 3T3 fibroblasts on the poly(methyl methacrylate) surface modified by constant UV irradiation].
Chaberska H; Kaczmarek H; Bazylak G
Polim Med; 2007; 37(3):13-9. PubMed ID: 18251201
[TBL] [Abstract][Full Text] [Related]
31. Mechanical and biological characteristics of diamond-like carbon coated poly aryl-ether-ether-ketone.
Wang H; Xu M; Zhang W; Kwok DT; Jiang J; Wu Z; Chu PK
Biomaterials; 2010 Nov; 31(32):8181-7. PubMed ID: 20692699
[TBL] [Abstract][Full Text] [Related]
32. In vitro cytotoxicity evaluation of natural rubber latex film surface coated with PMMA nanoparticles.
Anancharungsuk W; Polpanich D; Jangpatarapongsa K; Tangboriboonrat P
Colloids Surf B Biointerfaces; 2010 Jul; 78(2):328-33. PubMed ID: 20392612
[TBL] [Abstract][Full Text] [Related]
33. Fabrication and characterization of plasma-sprayed HA/SiO(2) coatings for biomedical application.
Morks MF
J Mech Behav Biomed Mater; 2008 Jan; 1(1):105-11. PubMed ID: 19627776
[TBL] [Abstract][Full Text] [Related]
34. [Electrochemical properties of biocompatible material hardness modifications on titanium and steel under mechanical loads].
Braun W; Walter U; Holbein R; Thull R
Biomed Tech (Berl); 2005 Apr; 50(4):100-6. PubMed ID: 15884706
[TBL] [Abstract][Full Text] [Related]
35. [The effect of surface free energy parameters of diamond-like carbon films deposited on medical polyethylene terephthalate on bacterial adhesion].
Wang J; Pan C; Li P; Leng Y; Chen J; Wan G; Yang P; Sun H; Huang N
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Apr; 23(2):342-5. PubMed ID: 16706362
[TBL] [Abstract][Full Text] [Related]
36. [Analysis of correlation degree between phase components and adsorptive amounts of serum proteins for DLC film].
Li B; Kang Y; Yin G; Zheng C
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2004 Aug; 21(4):549-53. PubMed ID: 15357429
[TBL] [Abstract][Full Text] [Related]
37. A novel ultra high molecular weight polyethylene-hyaluronan microcomposite for use in total joint replacements. II. Mechanical and tribological property evaluation.
Zhang M; Pare P; King R; James SP
J Biomed Mater Res A; 2007 Jul; 82(1):18-26. PubMed ID: 17265440
[TBL] [Abstract][Full Text] [Related]
38. Adhesion of staphylococcal and Caco-2 cells on diamond-like carbon polymer hybrid coating.
Kinnari TJ; Soininen A; Esteban J; Zamora N; Alakoski E; Kouri VP; Lappalainen R; Konttinen YT; Gomez-Barrena E; Tiainen VM
J Biomed Mater Res A; 2008 Sep; 86(3):760-8. PubMed ID: 18041722
[TBL] [Abstract][Full Text] [Related]
39. Anisotropy and oxidative resistance of highly crosslinked UHMWPE after deformation processing by solid-state ram extrusion.
Kurtz SM; Mazzucco D; Rimnac CM; Schroeder D
Biomaterials; 2006 Jan; 27(1):24-34. PubMed ID: 16085308
[TBL] [Abstract][Full Text] [Related]
40. Novel diamond-coated tools for dental drilling applications.
Jackson MJ; Sein H; Ahmed W; Woodwards R
J Med Eng Technol; 2007; 31(2):81-93. PubMed ID: 17365432
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]