These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

231 related articles for article (PubMed ID: 17504748)

  • 1. Electronic stopping power of liquid water for protons down to the Bragg peak.
    Emfietzoglou D; Pathak A; Nikjoo H
    Radiat Prot Dosimetry; 2007; 126(1-4):97-100. PubMed ID: 17504748
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accurate electron inelastic cross sections and stopping powers for liquid water over the 0.1-10 keV range based on an improved dielectric description of the Bethe surface.
    Emfietzoglou D; Nikjoo H
    Radiat Res; 2007 Jan; 167(1):110-20. PubMed ID: 17214512
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A dielectric response study of the electronic stopping power of liquid water for energetic protons and a new I-value for water.
    Emfietzoglou D; Garcia-Molina R; Kyriakou I; Abril I; Nikjoo H
    Phys Med Biol; 2009 Jun; 54(11):3451-72. PubMed ID: 19436107
    [TBL] [Abstract][Full Text] [Related]  

  • 4. W values of protons in liquid water.
    Baek WY; Grosswendt B
    Radiat Prot Dosimetry; 2007; 126(1-4):93-6. PubMed ID: 17517670
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Energy loss measurement of protons in liquid water.
    Siiskonen T; Kettunen H; Peräjärvi K; Javanainen A; Rossi M; Trzaska WH; Turunen J; Virtanen A
    Phys Med Biol; 2011 Apr; 56(8):2367-74. PubMed ID: 21427483
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monte-Carlo calculations of radial dose and restricted-let for protons in water.
    Emfietzoglou D; Karava K; Papamichael G; Moscovitch M
    Radiat Prot Dosimetry; 2004; 110(1-4):871-9. PubMed ID: 15353761
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Calculation of stopping power ratios for carbon ion dosimetry.
    Geithner O; Andreo P; Sobolevsky N; Hartmann G; Jäkel O
    Phys Med Biol; 2006 May; 51(9):2279-92. PubMed ID: 16625042
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Proton stopping powers in some low-Z elements.
    Sharada KS
    Radiat Res; 1993 Dec; 136(3):335-40. PubMed ID: 8278574
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ionization ranges of protons in water vapour in the energy range 1-100 keV.
    Baek WY; Grosswendt B; Willems G
    Radiat Prot Dosimetry; 2006; 122(1-4):32-5. PubMed ID: 17164281
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The antiproton depth-dose curve in water.
    Bassler N; Holzscheiter MH; Jäkel O; Knudsen HV; Kovacevic S
    Phys Med Biol; 2008 Feb; 53(3):793-805. PubMed ID: 18199915
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparative study of dielectric response function models for liquid water.
    Emfietzoglou D; Nikjoo H; Pathak A
    Radiat Prot Dosimetry; 2006; 122(1-4):61-5. PubMed ID: 17251250
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monte Carlo simulation and analysis of proton energy-deposition patterns in the Bragg peak.
    González-Muñoz G; Tilly N; Fernández-Varea JM; Ahnesjö A
    Phys Med Biol; 2008 Jun; 53(11):2857-75. PubMed ID: 18460751
    [TBL] [Abstract][Full Text] [Related]  

  • 13. New stopping power formula for intermediate energy electrons.
    Gümüş H
    Appl Radiat Isot; 2008 Dec; 66(12):1886-90. PubMed ID: 18586505
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A complete dielectric response model for liquid water: a solution of the Bethe ridge problem.
    Emfietzoglou D; Cucinotta FA; Nikjoo H
    Radiat Res; 2005 Aug; 164(2):202-11. PubMed ID: 16038591
    [TBL] [Abstract][Full Text] [Related]  

  • 15. W values of protons in alkane-based TE gases and dimethylether in the energy range 1-100 keV: measurements and additivity models.
    Baek WY; Grosswendt B; Willems G
    Radiat Prot Dosimetry; 2004; 110(1-4):61-8. PubMed ID: 15353623
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Precision measurements of the np scattering differential cross section in the intermediate energy region.
    Mermod P; Blomgren J; Nilsson L; Pomp S; Ohrn A; Osterlund M; Prokofiev A; Tippawan U
    Radiat Prot Dosimetry; 2007; 126(1-4):109-12. PubMed ID: 17595211
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte Carlo simulations on the water-to-air stopping power ratio for carbon ion dosimetry.
    Henkner K; Bassler N; Sobolevsky N; Jäkel O
    Med Phys; 2009 Apr; 36(4):1230-5. PubMed ID: 19472630
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Track studies in water vapor using a low-pressure cloud chamber. I. Macroscopic measurements.
    Stonell GP; Marshall M; Simmons JA
    Radiat Res; 1993 Dec; 136(3):341-52. PubMed ID: 8278575
    [TBL] [Abstract][Full Text] [Related]  

  • 19. On the clinical spatial resolution achievable with protons and heavier charged particle radiotherapy beams.
    Andreo P
    Phys Med Biol; 2009 Jun; 54(11):N205-15. PubMed ID: 19436099
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Inelastic scattering and stopping power of low-energy electrons (0.01-10 keV) in toluene.
    García G; Blanco F; Grau Carles A; Grau Malonda A
    Appl Radiat Isot; 2004; 60(2-4):481-5. PubMed ID: 14987689
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.