These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
118 related articles for article (PubMed ID: 17506594)
1. FISH and chips: chromosomal analysis on microfluidic platforms. Sieben VJ; Debes Marun CS; Pilarski PM; Kaigala GV; Pilarski LM; Backhouse CJ IET Nanobiotechnol; 2007 Jun; 1(3):27-35. PubMed ID: 17506594 [TBL] [Abstract][Full Text] [Related]
2. Metaphase FISH on a chip: miniaturized microfluidic device for fluorescence in situ hybridization. Vedarethinam I; Shah P; Dimaki M; Tumer Z; Tommerup N; Svendsen WE Sensors (Basel); 2010; 10(11):9831-46. PubMed ID: 22163442 [TBL] [Abstract][Full Text] [Related]
3. An integrated microfluidic chip for chromosome enumeration using fluorescence in situ hybridization. Sieben VJ; Debes-Marun CS; Pilarski LM; Backhouse CJ Lab Chip; 2008 Dec; 8(12):2151-6. PubMed ID: 19023479 [TBL] [Abstract][Full Text] [Related]
4. A fluorescence in situ hybridization (FISH) microfluidic platform for detection of HER2 amplification in cancer cells. Kao KJ; Tai CH; Chang WH; Yeh TS; Chen TC; Lee GB Biosens Bioelectron; 2015 Jul; 69():272-9. PubMed ID: 25770459 [TBL] [Abstract][Full Text] [Related]
5. Microdevice in Cellular Pathology: Microfluidic Platforms for Fluorescence in situ Hybridization and Analysis of Circulating Tumor Cells. Sato K Anal Sci; 2015; 31(9):867-73. PubMed ID: 26353951 [TBL] [Abstract][Full Text] [Related]
6. Risk stratification of plasma cell neoplasm: insights from plasma cell-specific cytoplasmic immunoglobulin fluorescence in situ hybridization (cIg FISH) vs. conventional FISH. Dong H; Yang HS; Jagannath S; Stephenson CF; Brenholz P; Mazumder A; Chari A Clin Lymphoma Myeloma Leuk; 2012 Oct; 12(5):366-74. PubMed ID: 22658896 [TBL] [Abstract][Full Text] [Related]
7. FISH and chips: a review of microfluidic platforms for FISH analysis. Rodriguez-Mateos P; Azevedo NF; Almeida C; Pamme N Med Microbiol Immunol; 2020 Jun; 209(3):373-391. PubMed ID: 31965296 [TBL] [Abstract][Full Text] [Related]
8. FISH-in-CHIPS: A Microfluidic Platform for Molecular Typing of Cancer Cells. Perez-Toralla K; Mottet G; Tulukcuoglu-Guneri E; Champ J; Bidard FC; Pierga JY; Klijanienko J; Draskovic I; Malaquin L; Viovy JL; Descroix S Methods Mol Biol; 2017; 1547():211-220. PubMed ID: 28044298 [TBL] [Abstract][Full Text] [Related]
9. FISH in chips: turning microfluidic fluorescence in situ hybridization into a quantitative and clinically reliable molecular diagnosis tool. Perez-Toralla K; Mottet G; Guneri ET; Champ J; Bidard FC; Pierga JY; Klijanienko J; Draskovic I; Malaquin L; Viovy JL; Descroix S Lab Chip; 2015 Feb; 15(3):811-22. PubMed ID: 25474258 [TBL] [Abstract][Full Text] [Related]
10. Stimulus-Responsive Microfluidic Interface Enables Efficient Enrichment and Cytogenetic Profiling of Circulating Myeloma Cells. Liu Y; Su R; Song J; Yu X; Lin S; Zhu Z; Yang Y; Zhang M; Yang L; Zhang H; Xu X; Yang C ACS Appl Mater Interfaces; 2021 Apr; 13(13):14920-14927. PubMed ID: 33755428 [TBL] [Abstract][Full Text] [Related]
11. Microfluidic Device for On-Chip Immunophenotyping and Cytogenetic Analysis of Rare Biological Cells. M Weerakoon-Ratnayake K; Vaidyanathan S; Larky N; Dathathreya K; Hu M; Jose J; Mog S; August K; K Godwin A; L Hupert M; A Witek M; A Soper S Cells; 2020 Feb; 9(2):. PubMed ID: 32102446 [TBL] [Abstract][Full Text] [Related]
12. Sensitive detection using microfluidics technology of single cell PCR products from high and low abundance IgH VDJ templates in multiple myeloma. Pilarski LM; Lauzon J; Strachan E; Adamia S; Atrazhev A; Belch AR; Backhouse CJ J Immunol Methods; 2005 Oct; 305(1):94-105. PubMed ID: 16150455 [TBL] [Abstract][Full Text] [Related]
13. Liquid-based hybridization assay with real-time detection in miniaturized array platforms. Guerasimova A; Nyarsik L; Liu JP; Schwartz R; Lange M; Lehrach H; Janitz M Biomol Eng; 2006 Mar; 23(1):35-40. PubMed ID: 16298548 [TBL] [Abstract][Full Text] [Related]
14. A retrospective analysis of cytogenetic and clinical characteristics in patients with multiple myeloma. He J; Yang L; Meng X; Wei G; Wu W; Han X; Zheng G; Zheng W; Ye X; Shi J; Xie W; Zhang J; Huang H; Lin M; Cai Z Am J Med Sci; 2013 Feb; 345(2):88-93. PubMed ID: 22986611 [TBL] [Abstract][Full Text] [Related]
15. Two-dimensional micro-bubble actuator array to enhance the efficiency of molecular beacon based DNA micro-biosensors. Deng P; Lee YK; Cheng P Biosens Bioelectron; 2006 Feb; 21(8):1443-50. PubMed ID: 16099153 [TBL] [Abstract][Full Text] [Related]
16. Sequential analysis of chromosome aberrations in multiple myeloma during disease progression. Wu KL; Beverloo B; Velthuizen SJ; Sonneveld P Clin Lymphoma Myeloma; 2007 Jan; 7(4):280-5. PubMed ID: 17324335 [TBL] [Abstract][Full Text] [Related]
17. Fish-on-a-chip: a sensitive detection microfluidic system for Alzheimer's disease. Devadhasan JP; Kim S; An J J Biomed Sci; 2011 May; 18(1):33. PubMed ID: 21619660 [TBL] [Abstract][Full Text] [Related]
18. MiRNA detection at single-cell resolution using microfluidic LNA flow-FISH. Wu M; Piccini ME; Singh AK Methods Mol Biol; 2014; 1211():245-60. PubMed ID: 25218391 [TBL] [Abstract][Full Text] [Related]
19. microFIND(®) approach to fluorescent in situ hybridization (FISH). Zanardi A; Barborini E; Carbone R Methods Mol Biol; 2013; 949():433-49. PubMed ID: 23329459 [TBL] [Abstract][Full Text] [Related]
20. Application of high throughput cell array technology to FISH: investigation of the role of deletion of p16 gene in leukemias. Lee DS; Lee JH; Min HC; Kim TY; Oh BR; Kim HY; Lee JY; Lee CK; Chun HG; Kim HC J Biotechnol; 2007 Jan; 127(3):355-60. PubMed ID: 16949174 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]