These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Fabrication of cytochrome c-poly(5-amino-2-napthalenesulfonic acid) electrode by one step procedure and direct electrochemistry of cytochrome c. Balamurugan A; Chen SM Biosens Bioelectron; 2008 Dec; 24(4):982-6. PubMed ID: 18774287 [TBL] [Abstract][Full Text] [Related]
3. Simultaneous electrochemical determination of superoxide anion radical and nitrite using Cu,ZnSOD immobilized on carbon nanotube in polypyrrole matrix. Rajesh S; Kanugula AK; Bhargava K; Ilavazhagan G; Kotamraju S; Karunakaran C Biosens Bioelectron; 2010 Oct; 26(2):689-95. PubMed ID: 20674329 [TBL] [Abstract][Full Text] [Related]
4. Superoxide radical biosensor based on a nano-composite containing cytochrome c. Rahimi P; Ghourchian H; Rafiee-Pour HA Analyst; 2011 Sep; 136(18):3803-8. PubMed ID: 21804961 [TBL] [Abstract][Full Text] [Related]
5. A sensor for superoxide in aqueous and organic/aqueous media based on immobilized cytochrome c on binary self-assembled monolayers. Ji X; Ren J; Jin J; Nakamura T Biosens Bioelectron; 2007 Sep; 23(2):241-7. PubMed ID: 17532618 [TBL] [Abstract][Full Text] [Related]
6. Lipid-bonded conducting polymer layers for a model biomembrane: application to superoxide biosensors. Kwon NH; Rahman MA; Won MS; Shim YB Anal Chem; 2006 Jan; 78(1):52-60. PubMed ID: 16383310 [TBL] [Abstract][Full Text] [Related]
7. The biosensor based on the pyruvate oxidase modified conducting polymer for phosphate ions determinations. Rahman MA; Park DS; Chang SC; McNeil CJ; Shim YB Biosens Bioelectron; 2006 Jan; 21(7):1116-24. PubMed ID: 15893466 [TBL] [Abstract][Full Text] [Related]
8. Immobilization and electrochemical redox behavior of cytochrome c on fullerene film-modified electrodes. D'Souza F; Rogers LM; O'Dell ES; Kochman A; Kutner W Bioelectrochemistry; 2005 Apr; 66(1-2):35-40. PubMed ID: 15833700 [TBL] [Abstract][Full Text] [Related]
9. Impedance studies of a nano-structured conducting polymer and its application to the design of reliable scaffolds for impedimetric biosensors. Shamsipur M; Kazemi SH; Mousavi MF Biosens Bioelectron; 2008 Sep; 24(1):104-10. PubMed ID: 18457942 [TBL] [Abstract][Full Text] [Related]
10. The potential use of hydrazine as an alternative to peroxidase in a biosensor: comparison between hydrazine and HRP-based glucose sensors. Rahman MA; Won MS; Shim YB Biosens Bioelectron; 2005 Aug; 21(2):257-65. PubMed ID: 16023952 [TBL] [Abstract][Full Text] [Related]
11. Supramolecular-mediated immobilization of L-phenylalanine dehydrogenase on cyclodextrin-coated Au electrodes for biosensor applications. Villalonga R; Fujii A; Shinohara H; Asano Y; Cao R; Tachibana S; Ortiz P Biotechnol Lett; 2007 Mar; 29(3):447-52. PubMed ID: 17237972 [TBL] [Abstract][Full Text] [Related]
12. Characterization of protein-attached conducting polymer monolayer. Kim HJ; Lee KS; Won MS; Shim YB Langmuir; 2008 Feb; 24(3):1087-93. PubMed ID: 18166065 [TBL] [Abstract][Full Text] [Related]
13. Direct electrochemistry and electrocatalytic activity of cytochrome c covalently immobilized on a boron-doped nanocrystalline diamond electrode. Zhou Y; Zhi J; Zou Y; Zhang W; Lee ST Anal Chem; 2008 Jun; 80(11):4141-6. PubMed ID: 18447324 [TBL] [Abstract][Full Text] [Related]
14. An electrochemical sulfite biosensor based on gold coated magnetic nanoparticles modified gold electrode. Rawal R; Chawla S; Pundir CS Biosens Bioelectron; 2012 Jan; 31(1):144-50. PubMed ID: 22035973 [TBL] [Abstract][Full Text] [Related]
15. Electrochemical characterization of biosensor based on nitrite reductase and methyl viologen co-immobilized glassy carbon electrode. Quan D; Min DG; Cha GS; Nam H Bioelectrochemistry; 2006 Oct; 69(2):267-75. PubMed ID: 16713751 [TBL] [Abstract][Full Text] [Related]
16. Third-generation superoxide anion sensor based on superoxide dismutase directly immobilized by sol-gel thin film on gold electrode. Di J; Bi S; Zhang M Biosens Bioelectron; 2004 Jun; 19(11):1479-86. PubMed ID: 15093220 [TBL] [Abstract][Full Text] [Related]
17. Direct electrochemistry behavior of cytochrome c/L-cysteine modified electrode and its electrocatalytic oxidation to nitric oxide. Liu YC; Cui SQ; Zhao J; Yang ZS Bioelectrochemistry; 2007 May; 70(2):416-20. PubMed ID: 16872916 [TBL] [Abstract][Full Text] [Related]
18. A novel nitrite biosensor based on conductometric electrode modified with cytochrome c nitrite reductase composite membrane. Zhang Z; Xia S; Leonard D; Jaffrezic-Renault N; Zhang J; Bessueille F; Goepfert Y; Wang X; Chen L; Zhu Z; Zhao J; Almeida MG; Silveira CM Biosens Bioelectron; 2009 Feb; 24(6):1574-9. PubMed ID: 18804367 [TBL] [Abstract][Full Text] [Related]
19. Direct mediatorless electron transport between the monolayer of photosystem II and poly(mercapto-p-benzoquinone) modified gold electrode--new design of biosensor for herbicide detection. Maly J; Masojidek J; Masci A; Ilie M; Cianci E; Foglietti V; Vastarella W; Pilloton R Biosens Bioelectron; 2005 Dec; 21(6):923-32. PubMed ID: 16257662 [TBL] [Abstract][Full Text] [Related]
20. Hydrogen peroxide biosensor based on direct electrochemistry of soybean peroxidase immobilized on single-walled carbon nanohorn modified electrode. Shi L; Liu X; Niu W; Li H; Han S; Chen J; Xu G Biosens Bioelectron; 2009 Jan; 24(5):1159-63. PubMed ID: 18703329 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]