These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 1751127)

  • 1. A unique, efficient, implantable, electromechanical, total artificial heart.
    Takatani S; Shiono M; Sasaki T; Sakuma I; Glueck J; Sekela M; Noon G; Nose Y; DeBakey M
    ASAIO Trans; 1991; 37(3):M238-40. PubMed ID: 1751127
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of a totally implantable electromechanical total artificial heart: Baylor TAH.
    Takatani S; Shiono M; Sasaki T; Glueck J; Noon GP; Nosé Y; DeBakey ME
    Artif Organs; 1992 Aug; 16(4):398-406. PubMed ID: 10078282
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultracompact, completely implantable permanent use electromechanical ventricular assist device and total artificial heart.
    Honda N; Inamoto T; Nogawa M; Takatani S
    Artif Organs; 1999 Mar; 23(3):253-61. PubMed ID: 10198717
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Versatile one-piece total artificial heart for bridge to transplantation or permanent heart replacement.
    Orime Y; Takatani S; Shiono M; Sasaki T; Minato N; Ohara Y; Swenson CA; Noon GP; Nosé Y; DeBakey ME
    Artif Organs; 1992 Dec; 16(6):607-13. PubMed ID: 1482331
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A biolized, compact, low noise, high performance implantable electromechanical ventricular assist system.
    Sasaki T; Takatani S; Shiono M; Sakuma I; Noon GP; Nosé Y; DeBakey ME
    ASAIO Trans; 1991; 37(3):M249-51. PubMed ID: 1751133
    [TBL] [Abstract][Full Text] [Related]  

  • 6. One piece ultracompact totally implantable electromechanical total artificial heart for permanent use.
    Takatani S; Sakamoto T; Ohuchi K; Nakamura M; Mizuno T; Arai H
    ASAIO J; 2002; 48(5):538-45. PubMed ID: 12296576
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Left and right pump output control in one-piece electromechanical total artificial heart.
    Takatani S; Shiono M; Sasaki T; Orime Y; Sakuma I; Noon G; Nosé Y; DeBakey M
    Artif Organs; 1993 Mar; 17(3):176-84. PubMed ID: 8215943
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of totally implantable electromechanical artificial heart systems: Baylor ventricular assist system.
    Sasaki T; Takatani S; Shiono M; Sakuma I; Glueck J; Noon GP; Nosé Y; DeBakey ME
    Artif Organs; 1992 Aug; 16(4):407-13. PubMed ID: 10078283
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A moving-actuator type electromechanical total artificial heart--Part I: Linear type and mock circulation experiments.
    Min BG; Kim HC; Lee SH; Kim JW; Kim JT; Kim IY; Kim SW; Diegel PD; Olsen DB
    IEEE Trans Biomed Eng; 1990 Dec; 37(12):1186-94. PubMed ID: 2289792
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An electrohydraulic total artificial heart with a separately placed actuator.
    Taenaka Y; Sekii H; Tatsumi E; Nakatani T; Sasaki E; Yagura A; Akagi H; Masuzawa T; Goto M; Matsuo Y
    ASAIO Trans; 1990; 36(3):M242-5. PubMed ID: 2252667
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Auxiliary total artificial heart: A compact electromechanical artificial heart working simultaneously with the natural heart.
    Andrade A; Nicolosi D; Lucchi J; Biscegli J; Arruda AC; Ohashi Y; Mueller J; Tayama E; Glueck J; Nosé Y
    Artif Organs; 1999 Sep; 23(9):876-80. PubMed ID: 10491037
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cardiac output regulation in the moving actuator total artificial heart without a compliance chamber.
    Kim HC; Min BG
    ASAIO J; 1992; 38(4):846-50. PubMed ID: 1450484
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Helmholtz Total Artificial Heart Labtype.
    Kaufmann R; Reul H; Rau G
    Artif Organs; 1994 Jul; 18(7):537-42. PubMed ID: 7980100
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Proposal of a new electromechanical total artificial heart: the TAH Serpentina.
    Sauer IM; Frank J; Bücherl ES
    Artif Organs; 1999 Mar; 23(3):290-1. PubMed ID: 10198723
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ovalis TAH: development and in vitro testing of a new electromechanical energy converter for a total artificial heart.
    Sauer IM; Frank J; Spiegelberg A; Bücherl ES
    ASAIO J; 2000; 46(6):744-8. PubMed ID: 11110274
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A completely implantable total artificial heart system.
    Snyder A; Rosenberg G; Weiss W; Pierce W; Pae W; Marlotte J; Nazarian R; Ford S
    ASAIO Trans; 1991; 37(3):M237-8. PubMed ID: 1751126
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Current status of permanent total artificial hearts.
    Davis PK; Rosenberg G; Snyder AJ; Pierce WS
    Ann Thorac Surg; 1989 Jan; 47(1):172-8. PubMed ID: 2912392
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Development of the E4T electrohydraulic total artificial heart.
    Himley SC; Butler KC; Massiello A; Chen J; Irie H; Harasaki H; Kiraly RJ; Golding L; Takatani S; Nosé Y
    ASAIO Trans; 1990; 36(3):M234-7. PubMed ID: 2252665
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Totally implantable total artificial heart and ventricular assist device with multipurpose miniature electromechanical energy system.
    Takatani S; Orime Y; Tasai K; Ohara Y; Naito K; Mizuguchi K; Makinouchi K; Damm G; Glueck J; Ling J
    Artif Organs; 1994 Jan; 18(1):80-92. PubMed ID: 8141662
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A motor integrated regenerative pump as the actuator of an electrohydraulic totally implantable artificial heart.
    Masuzawa T; Taenaka Y; Kinoshita M; Nakatani T; Akagi H; Takano H; Fukui Y; Sasagawa H; Takahashi K
    ASAIO J; 1992; 38(3):M232-6. PubMed ID: 1457855
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.