These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Description of a flow optimized oxygenator with integrated pulsatile pump. Borchardt R; Schlanstein P; Arens J; Graefe R; Schreiber F; Schmitz-Rode T; Steinseifer U Artif Organs; 2010 Nov; 34(11):904-10. PubMed ID: 21092033 [TBL] [Abstract][Full Text] [Related]
5. Feasibility of a new hollow fiber silicone membrane oxygenator for long-term ECMO application. Kawahito S; Maeda T; Motomura T; Takano T; Nonaka K; Linneweber J; Ichikawa S; Ishitoya H; Hanazaki K; Glueck J; Sato K; Nosé Y J Med Invest; 2002 Aug; 49(3-4):156-62. PubMed ID: 12323005 [TBL] [Abstract][Full Text] [Related]
6. Development of a membrane oxygenator for ECMO using a novel fine silicone hollow fiber. Funakubo A; Higami T; Sakuma I; Fukui Y; Kawamura T; Sato K; Sueoka A; Nosé Y ASAIO J; 1996; 42(5):M837-40. PubMed ID: 8945001 [TBL] [Abstract][Full Text] [Related]
7. Development of a new silicone membrane oxygenator for ECMO. Nakata K; Maeda T; Murabayashi S; Yoshikawa M; Takano T; Iwasaki A; Nonaka K; Linneweber J; Kawahito S; Glueck J; Sato K; Kuwana J; Nosé Y Ann Thorac Cardiovasc Surg; 2000 Dec; 6(6):373-7. PubMed ID: 11173351 [TBL] [Abstract][Full Text] [Related]
8. A miniaturized extracorporeal membrane oxygenator with integrated rotary blood pump: preclinical in vivo testing. Kopp R; Bensberg R; Arens J; Steinseifer U; Schmitz-Rode T; Rossaint R; Henzler D ASAIO J; 2011; 57(3):158-63. PubMed ID: 21317635 [TBL] [Abstract][Full Text] [Related]
10. Preclinical evaluation of a hollow fiber silicone membrane oxygenator for extracorporeal membrane oxygenator application. Maeda T; Iwasaki A; Kawahito S; Nakata K; Nonaka K; Linneweber J; Schulte-Eistrup S; Takano T; Yoshikawa M; Sato K; Kuwana J; Murabayashi S; Nosé Y ASAIO J; 2000; 46(4):426-30. PubMed ID: 10926139 [TBL] [Abstract][Full Text] [Related]
11. A wet-primed extracorporeal membrane oxygenation circuit with hollow-fiber membrane oxygenator maintains adequate function for use during cardiopulmonary resuscitation after 2 weeks on standby. Karimova A; Robertson A; Cross N; Smith L; O'callaghan M; Tuleu C; Long P; Beeton A; Han J; Ridout D; Goldman A; Brown K Crit Care Med; 2005 Jul; 33(7):1572-6. PubMed ID: 16003064 [TBL] [Abstract][Full Text] [Related]
12. Gas exchange efficiency of an oxygenator with integrated pulsatile displacement blood pump for neonatal patients. Schlanstein PC; Borchardt R; Mager I; Schmitz-Rode T; Steinseifer U; Arens J Int J Artif Organs; 2014 Jan; 37(1):88-92. PubMed ID: 24634337 [TBL] [Abstract][Full Text] [Related]
13. DIDECMO: a new polymethylpentene oxygenator for pediatric extracorporeal membrane oxygenation. Agati S; Ciccarello G; Fachile N; Scappatura RM; Grasso D; Salvo D; Undar A; Mignosa C ASAIO J; 2006; 52(5):509-12. PubMed ID: 16966847 [TBL] [Abstract][Full Text] [Related]
14. Preclinical evaluation of a new hollow fiber silicone membrane oxygenator for pediatric cardiopulmonary bypass: ex-vivo study. Kawahito S; Haraguchi S; Maeda T; Motomura T; Takano T; Nonaka K; Linneweber J; Ichikawa S; Kawamura M; Ishitoya H; Glueck J; Sato K; Nosé Y Ann Thorac Cardiovasc Surg; 2002 Feb; 8(1):7-11. PubMed ID: 11916436 [TBL] [Abstract][Full Text] [Related]
15. In vitro evaluation of the Mera Silox-S 0.5 and 0.8 m 2 silicone hollow-fibre membrane oxygenator for use in neonatal ECMO. Rais-Bahrami K; Mikesell G; Seale WR; Rivera O; Hearty JP; Short BL Perfusion; 1992; 7(4):315-20. PubMed ID: 10148027 [TBL] [Abstract][Full Text] [Related]
16. Prolonged extracorporeal membrane oxygenation in sheep with a hollow-fiber oxygenator and a centrifugal pump. Palder SB; Shaheen KW; Whittlesey GC; Nowlen TT; Kundu SK; Klein MD ASAIO Trans; 1988; 34(3):820-2. PubMed ID: 3196606 [TBL] [Abstract][Full Text] [Related]
17. Development of a silicone hollow fiber membrane oxygenator for ECMO application. Yamane S; Ohashi Y; Sueoka A; Sato K; Kuwana J; Nosé Y ASAIO J; 1998; 44(5):M384-7. PubMed ID: 9804456 [TBL] [Abstract][Full Text] [Related]
19. Introduction of a new oxygenator including a tight fiber for long-term ECMO in infants. Kind K; Reiss N; Knobl HJ; Blanz U; Körfer R ASAIO J; 2006; 52(2):217-8. PubMed ID: 16557113 [TBL] [Abstract][Full Text] [Related]
20. A description of a prototype miniature extracorporeal membrane oxygenation circuit using current technologies in a sheep model. Terry B; Gunst G; Melchior R; Wolfe D; Feocco N; Graham S; Searles B; Darling E J Extra Corpor Technol; 2005 Sep; 37(3):315-7. PubMed ID: 16350388 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]