BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 1751214)

  • 1. Quantitative gas transfer into and out of circulating venous blood by means of an intravenacaval oxygenator.
    Bagley B; Bagley A; Henrie J; Froerer C; Brohamer J; Burkart J; Mortensen JD
    ASAIO Trans; 1991; 37(3):M413-5. PubMed ID: 1751214
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Use of an intravascular oxygenator/carbon dioxide removal device in an ovine smoke inhalation injury model.
    Cox CS; Zwischenberger JB; Traber LD; Traber DL; Herndon DN
    ASAIO Trans; 1991; 37(3):M411-3. PubMed ID: 1751213
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vivo gas transfer performance of the intravascular oxygenator in acute respiratory failure.
    Conrad SA; Zwischenberger JB; Eggerstedt JM; Bidani A
    Artif Organs; 1994 Nov; 18(11):840-5. PubMed ID: 7864734
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intravascular membrane oxygenation and carbon dioxide removal with IVOX: can improved design and permissive hypercapnia achieve adequate respiratory support during severe respiratory failure?
    Zwischenberger JB; Cardenas VJ; Tao W; Niranjan SC; Clark JW; Bidani A
    Artif Organs; 1994 Nov; 18(11):833-9. PubMed ID: 7864733
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Preliminary study of intravascular oxygenator in braid in vitro].
    Fu H; Tang Y; An Q; Du L; Liu J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Dec; 26(6):1345-8, 1352. PubMed ID: 20095500
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improved gas exchange performance of the intravascular oxygenator by active blood mixing.
    Tao W; Schroeder T; Bidani A; Cardenas VJ; Nguyen PD; Bradford DW; Traber DL; Zwischenberger JB
    ASAIO J; 1994; 40(3):M527-32. PubMed ID: 8555572
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intravascular oxygenator: a new alternative method for augmenting blood gas transfer in patients with acute respiratory failure.
    Mortensen JD
    Artif Organs; 1992 Feb; 16(1):75-82. PubMed ID: 1300104
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stragegies to reduce surface area requirements for carbon dioxide removal for an intravenacaval gas exchange device.
    Tao W; Bidani A; Cardenas VJ; Niranjan SC; Zwischenberger JB
    ASAIO J; 1995; 41(3):M567-72. PubMed ID: 8573869
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The intravascular oxygenator (IVOX): preliminary results of a new means of performing extrapulmonary gas exchange.
    Gentilello LM; Jurkovich GJ; Gubler KD; Anardi DM; Heiskell R
    J Trauma; 1993 Sep; 35(3):399-404. PubMed ID: 8371298
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance of an intravenous gas exchanger (IVOX) in a venovenous bypass circuit.
    Tao W; Zwischenberger JB; Nguyen TT; Tzouanakis AE; Matheis EJ; Traber DL; Bidani A
    Ann Thorac Surg; 1994 Jun; 57(6):1484-90; discussion 1490-1. PubMed ID: 8010791
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Major findings from the clinical trials of the intravascular oxygenator.
    Conrad SA; Bagley A; Bagley B; Schaap RN
    Artif Organs; 1994 Nov; 18(11):846-63. PubMed ID: 7864735
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intravascular membrane oxygenator and carbon dioxide removal devices: a review of performance and improvements.
    Zwischenberger JB; Tao W; Bidani A
    ASAIO J; 1999; 45(1):41-6. PubMed ID: 9952005
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new intravascular membrane oxygenator to augment blood gas transfer in patients with acute respiratory failure.
    Zwischenberger JB; Cox CS
    Tex Med; 1991 Dec; 87(12):60-3. PubMed ID: 1801294
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development and current status of a new intracorporeal membrane oxygenator (IVOX).
    Cox CS; Zwischenberger JB; Kurusz M
    Perfusion; 1991; 6(4):291-6. PubMed ID: 10149513
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Present status of IVOX device].
    Terada Y
    Rinsho Kyobu Geka; 1994 Dec; 14(6):461-4. PubMed ID: 9423123
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Rate of thrombus accumulation on intravenacaval IVOX devices explanted from human clinical trial patients with acute respiratory failure.
    Imai H; Schaap RN; Mortensen JD
    Artif Organs; 1994 Nov; 18(11):818-21. PubMed ID: 7864730
    [TBL] [Abstract][Full Text] [Related]  

  • 17. IVOX with gradual permissive hypercapnia: a new management technique for respiratory failure.
    Zwischenberger JB; Nguyen TT; Tao W; Bush PE; Cox CS; Traber DL; Herndon DN; Bidani A
    J Surg Res; 1994 Jul; 57(1):99-105. PubMed ID: 8041157
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Conceptual and design features of a practical, clinically effective intravenous mechanical blood oxygen/carbon dioxide exchange device (IVOX).
    Mortensen JD; Berry G
    Int J Artif Organs; 1989 Jun; 12(6):384-9. PubMed ID: 2777397
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intracorporeal CO2 removal and permissive hypercapnia to reduce airway pressure in acute respiratory failure. The theoretical basis for permissive hypercapnia with IVOX.
    Cox CS; Zwischenberger JB; Graves DF; Niranjan SC; Bidani A
    ASAIO J; 1993; 39(2):97-102. PubMed ID: 8324269
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Significant enhancement of carbon dioxide removal by a new prototype IVOX.
    Nguyen TT; Zwischenberger JB; Tao W; Traber DL; Herndon DN; Duncan CC; Bush P; Bidani A
    ASAIO J; 1993; 39(3):M719-24. PubMed ID: 8268632
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.