These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

92 related articles for article (PubMed ID: 1751222)

  • 1. Continuous monitoring of artificial heart pump performance.
    Sasaki E; Nakatani T; Taenaka Y; Noda H; Tatsumi E; Akagi H; Masuzawa T; Goto M; Sakaki M; Matsuo Y
    ASAIO Trans; 1991; 37(3):M429-30. PubMed ID: 1751222
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Novel method to determine instantaneous blood volume in pulsatile blood pump using electrical impedance.
    Sasaki E; Nakatani T; Taenaka Y; Takano H; Hirose H
    Artif Organs; 1994 Aug; 18(8):603-10. PubMed ID: 7993196
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An implantable left ventricular assist system with an electrical impedance monitoring and control system.
    Nakatani T; Anai H; Taenaka Y; Akagi H; Masuzawa T; Baba Y; Sakaki M; Araki K; Inoue K; Matsuo Y
    ASAIO J; 1993; 39(3):M644-8. PubMed ID: 8268617
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development and in vivo evaluation of an implantable left ventricular assist system with an impedance based monitoring and control system.
    Nakatani T; Anai H; Eya K; Wakisaka Y; Toda K; Taenaka Y; Tatsumi E; Masuzawa T; Baba Y; Takano H
    ASAIO J; 1995; 41(3):M324-7. PubMed ID: 8573817
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An abdominally placed, implantable left ventricular assist system for long-term use.
    Nakatani T; Anai H; Goto M; Sasaki E; Taenaka Y; Kinoshita M; Akagi H; Masuzawa T; Baba Y; Sakaki M
    ASAIO J; 1992; 38(3):M631-3. PubMed ID: 1457937
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Factors influencing the accuracy of the cardiac output monitoring and diagnostic unit for pneumatic artificial hearts.
    Shaw WJ; Pantalos GM; Everett S; Olsen DB
    ASAIO Trans; 1990; 36(3):M264-8. PubMed ID: 2252674
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A transcutaneous optical information transmission system for implantable motor-driven artificial hearts.
    Mitamura Y; Okamoto E; Mikami T
    ASAIO Trans; 1990; 36(3):M278-80. PubMed ID: 2252677
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheter.
    Baan J; Jong TT; Kerkhof PL; Moene RJ; van Dijk AD; van der Velde ET; Koops J
    Cardiovasc Res; 1981 Jun; 15(6):328-34. PubMed ID: 7296590
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The measurement of cardia output by the thoracic impedance method.
    Adamicza A; Tutsek L; Nagy S
    Acta Physiol Hung; 1988; 71(3):395-408. PubMed ID: 3421117
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Recent developments in position sensors].
    Schaldach M; Bolz A; Jirmann J; Hutten H
    Biomed Tech (Berl); 1990; 35 Suppl 3():207-9. PubMed ID: 2078699
    [No Abstract]   [Full Text] [Related]  

  • 11. A motor integrated regenerative pump as the actuator of an electrohydraulic totally implantable artificial heart.
    Masuzawa T; Taenaka Y; Kinoshita M; Nakatani T; Akagi H; Takano H; Fukui Y; Sasagawa H; Takahashi K
    ASAIO J; 1992; 38(3):M232-6. PubMed ID: 1457855
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Continuous recording of cardiac output volume with the OptiQ system--experiences with clinical application].
    Soukup J; Henze D; Trawiel C; Trommler P; Hennig C; Radke J; Menzel M
    Anaesthesiol Reanim; 2000; 25(6):158-63. PubMed ID: 11194384
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Continuous registration of cardiac output with a new computer system designed for hot-film anemometry: an in vitro study.
    Hasenkam JM; Ostergaard JH; Pedersen EM; Paulsen PK; Nissen T
    Life Support Syst; 1986; 4(4):335-44. PubMed ID: 2951566
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An electrohydraulic total artificial heart with a separately placed actuator.
    Taenaka Y; Sekii H; Tatsumi E; Nakatani T; Sasaki E; Yagura A; Akagi H; Masuzawa T; Goto M; Matsuo Y
    ASAIO Trans; 1990; 36(3):M242-5. PubMed ID: 2252667
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Four-terminal impedance monitoring of cardiac output: an elegant clinical application of a classical engineering trick.
    Kroll MW
    Europace; 2010 May; 12(5):616-7. PubMed ID: 20421223
    [No Abstract]   [Full Text] [Related]  

  • 16. Non-invasive beat-to-beat cardiac output monitoring by an improved method of transthoracic bioimpedance measurement.
    Fortin J; Habenbacher W; Heller A; Hacker A; Grüllenberger R; Innerhofer J; Passath H; Wagner Ch; Haitchi G; Flotzinger D; Pacher R; Wach P
    Comput Biol Med; 2006 Nov; 36(11):1185-203. PubMed ID: 16131462
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of a total artificial heart right stroke volume limiter on left-right hemodynamic balance.
    Fukamachi K; Massiello AL; Kiraly RJ; Chen JF; Himley S; Davies C; Fukumura F; Muramoto K; Olsen E; Golding LA
    ASAIO J; 1993; 39(3):M410-4. PubMed ID: 8268568
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cardiac output and left atrial pressure monitoring by right ventricular pressure waveform analysis for potential implantable device application.
    Xu D; Olivier NB; Mukkamala R
    IEEE Trans Biomed Eng; 2009 Sep; 56(9):2335-9. PubMed ID: 19457736
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Third model of the undulation pump total artificial heart.
    Abe Y; Chinzei T; Isoyama T; Ono T; Mochizuki S; Saito I; Iwasaki K; Ishimaru M; Baba A; Kouno A; Ozeki T; Tohyama T; Imachi K
    ASAIO J; 2003; 49(1):123-7. PubMed ID: 12558319
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Validation of a semi-classical signal analysis method for stroke volume variation assessment: a comparison with the PiCCO technique.
    Laleg-Kirati TM; Médigue C; Papelier Y; Cottin F; Van de Louw A
    Ann Biomed Eng; 2010 Dec; 38(12):3618-29. PubMed ID: 20614241
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.