BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

569 related articles for article (PubMed ID: 17512939)

  • 1. Comparison of reversed-phase liquid chromatography-mass spectrometry with electrospray and atmospheric pressure chemical ionization for analysis of dietary tocopherols.
    Lanina SA; Toledo P; Sampels S; Kamal-Eldin A; Jastrebova JA
    J Chromatogr A; 2007 Jul; 1157(1-2):159-70. PubMed ID: 17512939
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantitative determination of endogenous sorbitol and fructose in human nerve tissues by atmospheric-pressure chemical ionization liquid chromatography/tandem mass spectrometry.
    Liang HR; Takagaki T; Foltz RL; Bennett P
    Rapid Commun Mass Spectrom; 2005; 19(16):2284-94. PubMed ID: 16034846
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of urinary phytoestrogens by HPLC-MS/MS: a comparison of atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI).
    Rybak ME; Parker DL; Pfeiffer CM
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Jan; 861(1):145-50. PubMed ID: 18068558
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of electrospray ionization and atmospheric pressure chemical ionization for simultaneous detection of estrone and its metabolites using high-performance liquid chromatography/tandem mass spectrometry.
    Hsu JF; Chang YC; Chen TH; Lin LC; Liao PC
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Dec; 860(1):49-56. PubMed ID: 17988961
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of tocopherols and tocotrienols in cereals by pressurized liquid extraction-liquid chromatography-mass spectrometry.
    Bustamante-Rangel M; Delgado-Zamarreño MM; Sánchez-Pérez A; Carabias-Martínez R
    Anal Chim Acta; 2007 Mar; 587(2):216-21. PubMed ID: 17386776
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantitative determination of acetylcholine in microdialysis samples using liquid chromatography/atmospheric pressure spray ionization mass spectrometry.
    Keski-Rahkonen P; Lehtonen M; Ihalainen J; Sarajärvi T; Auriola S
    Rapid Commun Mass Spectrom; 2007; 21(18):2933-43. PubMed ID: 17680629
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of atmospheric pressure photoionization, atmospheric pressure chemical ionization, and electrospray ionization mass spectrometry for analysis of lipids.
    Cai SS; Syage JA
    Anal Chem; 2006 Feb; 78(4):1191-9. PubMed ID: 16478111
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Negative APCI-LC/MS/MS method for determination of natural persistent halogenated products in marine biota.
    Haraguchi K; Kato Y; Atobe K; Okada S; Endo T; Matsubara F; Oguma T
    Anal Chem; 2008 Dec; 80(24):9748-55. PubMed ID: 19012416
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization for determining estrogenic chemicals in water by liquid chromatography tandem mass spectrometry with chemical derivatizations.
    Lien GW; Chen CY; Wang GS
    J Chromatogr A; 2009 Feb; 1216(6):956-66. PubMed ID: 19118834
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ion-pair high-performance liquid chromatography with diode array detection coupled to dual electrospray atmospheric pressure chemical ionization time-of-flight mass spectrometry for the determination of nucleotides in baby foods.
    Viñas P; Campillo N; Melgarejo GF; Vasallo MI; López-García I; Hernández-Córdoba M
    J Chromatogr A; 2010 Aug; 1217(32):5197-203. PubMed ID: 20580011
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comprehensive analysis of vitamin E constituents in human plasma by liquid chromatography-mass spectrometry.
    Nagy K; Courtet-Compondu MC; Holst B; Kussmann M
    Anal Chem; 2007 Sep; 79(18):7087-96. PubMed ID: 17696496
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ion suppression and enhancement effects of co-eluting analytes in multi-analyte approaches: systematic investigation using ultra-high-performance liquid chromatography/mass spectrometry with atmospheric-pressure chemical ionization or electrospray ionization.
    Remane D; Meyer MR; Wissenbach DK; Maurer HH
    Rapid Commun Mass Spectrom; 2010 Nov; 24(21):3103-8. PubMed ID: 20941756
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Validated assay for the simultaneous quantification of total vincristine and actinomycin-D concentrations in human EDTA plasma and of vincristine concentrations in human plasma ultrafiltrate by high-performance liquid chromatography coupled with tandem mass spectrometry.
    Damen CW; Israëls T; Caron HN; Schellens JH; Rosing H; Beijnen JH
    Rapid Commun Mass Spectrom; 2009 Mar; 23(6):763-74. PubMed ID: 19204931
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of estrogens and progestogens by mass spectrometric techniques (GC/MS, LC/MS and LC/MS/MS).
    Díaz-Cruz MS; López de Alda MJ; López R; Barceló D
    J Mass Spectrom; 2003 Sep; 38(9):917-23. PubMed ID: 14505318
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Capillary electrochromatography-mass spectrometry of zwitterionic surfactants.
    Norton D; Zheng J; Danielson ND; Shamsi SA
    Anal Chem; 2005 Nov; 77(21):6874-86. PubMed ID: 16255585
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High performance liquid chromatography/ion-trap mass spectrometry for separation and simultaneous determination of ethynylestradiol, gestodene, levonorgestrel, cyproterone acetate and desogestrel.
    Matejícek D; Kubán V
    Anal Chim Acta; 2007 Apr; 588(2):304-15. PubMed ID: 17386825
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultra-performance liquid chromatography/tandem mass spectrometric quantification of structurally diverse drug mixtures using an ESI-APCI multimode ionization source.
    Yu K; Di L; Kerns E; Li SQ; Alden P; Plumb RS
    Rapid Commun Mass Spectrom; 2007; 21(6):893-902. PubMed ID: 17295426
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of atmospheric pressure chemical ionization and electrospray ionization mass spectrometry for the detection of lignans from sesame seeds.
    Struijs K; Vincken JP; Gruppen H
    Rapid Commun Mass Spectrom; 2008 Nov; 22(22):3615-23. PubMed ID: 18946863
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The simultaneous quantification of phytosterols and tocopherols in liposomal formulations using validated atmospheric pressure chemical ionization- liquid chromatography -tandem mass spectrometry.
    Poudel A; Gachumi G; Badea I; Bashi ZD; El-Aneed A
    J Pharm Biomed Anal; 2020 May; 183():113104. PubMed ID: 32058287
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simultaneous separation and determination of coenzyme Q(10) and its process related impurities by NARP-HPLC and atmospheric pressure chemical ionization-mass spectrometry (APCI-MS).
    Nageswara Rao R; Kumar Talluri MV; Shinde DD
    J Pharm Biomed Anal; 2008 Jun; 47(2):230-7. PubMed ID: 18243624
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 29.