BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 17514423)

  • 1. Left ventricular volume measurement by the conductance catheter and variations in the hematocrit in small animals.
    Heimisch W; Schad H; Günzinger R
    Cardiovasc Eng; 2007 Jun; 7(2):43-6. PubMed ID: 17514423
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hematocrit measurement by dielectric spectroscopy.
    Treo EF; Felice CJ; Tirado MC; Valentinuzzi ME; Cervantes DO
    IEEE Trans Biomed Eng; 2005 Jan; 52(1):124-7. PubMed ID: 15651572
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Nonlinear conductance-volume relationship for murine conductance catheter measurement system.
    Wei CL; Valvano JW; Feldman MD; Pearce JA
    IEEE Trans Biomed Eng; 2005 Oct; 52(10):1654-61. PubMed ID: 16235651
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The trans-cardiac conductance method for on-line measurement of left ventricular volume: assessment of parallel conductance offset volume.
    Staal EM; Steendijk P; Baan J
    IEEE Trans Biomed Eng; 2003 Feb; 50(2):234-40. PubMed ID: 12665037
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Continuous right ventricular volumetry by fast-response thermodilution during right ventricular ischemia: head-to-head comparison with conductance catheter measurements.
    Hein M; Roehl AB; Baumert JH; Rossaint R; Steendijk P
    Crit Care Med; 2009 Nov; 37(11):2962-7. PubMed ID: 19770752
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A rat model of cardiopulmonary bypass with cardioplegic arrest and hemodynamic assessment by conductance catheter technique.
    Günzinger R; Wildhirt SM; Schad H; Heimisch W; Gurdan M; Mendler N; Grammer J; Lange R; Bauernschmitt R
    Basic Res Cardiol; 2007 Nov; 102(6):508-17. PubMed ID: 17668258
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The conductance volume catheter technique for measurement of left ventricular volume in young piglets.
    Cassidy SC; Teitel DF
    Pediatr Res; 1992 Jan; 31(1):85-90. PubMed ID: 1594337
    [TBL] [Abstract][Full Text] [Related]  

  • 8. eComment: left ventricular catheterization for pressure-volume loop measurements in small laboratory animals.
    Ugurlucan M; Furlani D; Klopsch C; Steinhoff G
    Interact Cardiovasc Thorac Surg; 2008 Oct; 7(5):927; discussion 927. PubMed ID: 18801819
    [No Abstract]   [Full Text] [Related]  

  • 9. Correlation of esophageal conductance measurements with aortic and left ventricular diameters and stroke volume.
    Hettrick DA; Battocletti JH; Pagel PS; Vurek GG; Tessmer JP; Kersten JR; Warltier DC
    IEEE Trans Biomed Eng; 2000 Apr; 47(4):559-64. PubMed ID: 10763303
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Analysis of the spatial sensitivity of conductance/admittance catheter ventricular volume estimation.
    Larson ER; Feldman MD; Valvano JW; Pearce JA
    IEEE Trans Biomed Eng; 2013 Aug; 60(8):2316-24. PubMed ID: 23559022
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Volume catheter parallel conductance varies between end-systole and end-diastole.
    Wei CL; Valvano JW; Feldman MD; Nahrendorf M; Peshock R; Pearce JA
    IEEE Trans Biomed Eng; 2007 Aug; 54(8):1480-9. PubMed ID: 17694869
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Does conductance catheter measurement system give consistent and reliable pressure-volume relations in rats?
    Wei CL; Kan CD; Wang JN; Wang YW; Chen CH; Tsai ML
    IEEE Trans Biomed Eng; 2011 Jun; 58(6):1804-13. PubMed ID: 21342837
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A justification for high resolution hematocrit measurement.
    Kelly ME; Luetkemeier MJ; Pantalos GM
    Med Sci Sports Exerc; 1994 May; 26(5):547-50. PubMed ID: 8007800
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Left ventricular function in the post-infarct failing mouse heart by magnetic resonance imaging and conductance catheter: a comparative analysis.
    Winter EM; Grauss RW; Atsma DE; Hogers B; Poelmann RE; van der Geest RJ; Tschöpe C; Schalij MJ; Gittenberger-de Groot AC; Steendijk P
    Acta Physiol (Oxf); 2008 Oct; 194(2):111-22. PubMed ID: 18419776
    [TBL] [Abstract][Full Text] [Related]  

  • 15. New and simplified method for multiple left ventricle catheterizations in small animals.
    Migneco F; Huang YC; Coyan GN; Birla RK
    Interact Cardiovasc Thorac Surg; 2008 Oct; 7(5):925-7. PubMed ID: 18653500
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of changes in cardiac output from the electrical impedance waveform in the forearm.
    Wang JJ; Wang PW; Liu CP; Lin SK; Hu WC; Kao T
    Physiol Meas; 2007 Sep; 28(9):989-99. PubMed ID: 17827648
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Artifacts in plasma volume changes due to hematology analyzer-derived hematocrit.
    Watson P; Maughan RJ
    Med Sci Sports Exerc; 2014 Jan; 46(1):52-9. PubMed ID: 23783261
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of automated methods of measuring hemoglobin and hematocrit in horses.
    Sorrell-Raschi LA; Tomasic M
    Am J Vet Res; 1998 Dec; 59(12):1519-22. PubMed ID: 9858398
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Calibration capacity of the conductance-to-volume conversion equations for the mouse conductance catheter measurement system.
    Wei CL; Shih MH
    IEEE Trans Biomed Eng; 2009 Jun; 56(6):1627-34. PubMed ID: 19272973
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of dsigma*/dt (max), a load independent index of contractility, in the canine.
    Black A; Grenz N; Niccole S; Arndt P; Lucht J; Nesvig K; Ewert D; Mulligan L
    Cardiovasc Eng; 2009 Jun; 9(2):49-55. PubMed ID: 19466542
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.