163 related articles for article (PubMed ID: 17520306)
1. The reduction of artifacts due to metal hip implants in CT-attenuation corrected PET images from hybrid PET/CT scanners.
Kennedy JA; Israel O; Frenkel A; Bar-Shalom R; Azhari H
Med Biol Eng Comput; 2007 Jun; 45(6):553-62. PubMed ID: 17520306
[TBL] [Abstract][Full Text] [Related]
2. The effect of metal artefact reduction on CT-based attenuation correction for PET imaging in the vicinity of metallic hip implants: a phantom study.
Harnish R; Prevrhal S; Alavi A; Zaidi H; Lang TF
Ann Nucl Med; 2014 Jul; 28(6):540-50. PubMed ID: 24710757
[TBL] [Abstract][Full Text] [Related]
3. Metal Artifact Reduction of CT Scans to Improve PET/CT.
van der Vos CS; Arens AIJ; Hamill JJ; Hofmann C; Panin VY; Meeuwis APW; Visser EP; de Geus-Oei LF
J Nucl Med; 2017 Nov; 58(11):1867-1872. PubMed ID: 28490470
[TBL] [Abstract][Full Text] [Related]
4. Reduction of artefacts caused by hip implants in CT-based attenuation-corrected PET images using 2-D interpolation of a virtual sinogram on an irregular grid.
Abdoli M; de Jong JR; Pruim J; Dierckx RA; Zaidi H
Eur J Nucl Med Mol Imaging; 2011 Dec; 38(12):2257-68. PubMed ID: 21850499
[TBL] [Abstract][Full Text] [Related]
5. Effects of MR surface coils on PET quantification.
MacDonald LR; Kohlmyer S; Liu C; Lewellen TK; Kinahan PE
Med Phys; 2011 Jun; 38(6):2948-56. PubMed ID: 21815368
[TBL] [Abstract][Full Text] [Related]
6. Metallic artifacts caused by dental metal prostheses on PET images: a PET/CT phantom study using different PET/CT scanners.
Shimamoto H; Kakimoto N; Fujino K; Hamada S; Shimosegawa E; Murakami S; Furukawa S; Hatazawa J
Ann Nucl Med; 2009 Jul; 23(5):443-9. PubMed ID: 19399580
[TBL] [Abstract][Full Text] [Related]
7. Artifacts at PET and PET/CT caused by metallic hip prosthetic material.
Goerres GW; Ziegler SI; Burger C; Berthold T; Von Schulthess GK; Buck A
Radiology; 2003 Feb; 226(2):577-84. PubMed ID: 12563158
[TBL] [Abstract][Full Text] [Related]
8. Do implanted pacemaker leads and ICD leads cause metal-related artifact in cardiac PET/CT?
DiFilippo FP; Brunken RC
J Nucl Med; 2005 Mar; 46(3):436-43. PubMed ID: 15750156
[TBL] [Abstract][Full Text] [Related]
9. A virtual sinogram method to reduce dental metallic implant artefacts in computed tomography-based attenuation correction for PET.
Abdoli M; Ay MR; Ahmadian A; Zaidi H
Nucl Med Commun; 2010 Jan; 31(1):22-31. PubMed ID: 19829166
[TBL] [Abstract][Full Text] [Related]
10. Multi-Atlas-Based Attenuation Correction for Brain 18F-FDG PET Imaging Using a Time-of-Flight PET/MR Scanner: Comparison with Clinical Single-Atlas- and CT-Based Attenuation Correction.
Sekine T; Burgos N; Warnock G; Huellner M; Buck A; Ter Voert EE; Cardoso MJ; Hutton BF; Ourselin S; Veit-Haibach P; Delso G
J Nucl Med; 2016 Aug; 57(8):1258-64. PubMed ID: 27013697
[TBL] [Abstract][Full Text] [Related]
11. Characterization of a perirectal artifact in 18F-FDG PET/CT.
Lodge MA; Chaudhry MA; Udall DN; Wahl RL
J Nucl Med; 2010 Oct; 51(10):1501-6. PubMed ID: 20847169
[TBL] [Abstract][Full Text] [Related]
12. Whole-body 18F-FDG PET/CT in the presence of truncation artifacts.
Beyer T; Bockisch A; Kühl H; Martinez MJ
J Nucl Med; 2006 Jan; 47(1):91-9. PubMed ID: 16391192
[TBL] [Abstract][Full Text] [Related]
13. Improving CT-Based PET Attenuation Correction in the Vicinity of Metal Implants by an Iterative Metal Artifact Reduction Algorithm of CT Data and Its Comparison to Dual-Energy-Based Strategies: A Phantom Study.
Schabel C; Gatidis S; Bongers M; Hüttig F; Bier G; Kupferschlaeger J; Bamberg F; la Fougère C; Nikolaou K; Pfannenberg C
Invest Radiol; 2017 Jan; 52(1):61-65. PubMed ID: 27416330
[TBL] [Abstract][Full Text] [Related]
14. Impact of different metal artifact reduction techniques on attenuation correction in 18F-FDG PET/CT examinations.
Martin O; Aissa J; Boos J; Wingendorf K; Latz D; Buchbender C; Gaspers S; Antke C; Sedlmair M; Antoch G; Schaarschmidt BM
Br J Radiol; 2020 Jan; 93(1105):20190069. PubMed ID: 31642702
[TBL] [Abstract][Full Text] [Related]
15. Assessment of errors caused by X-ray scatter and use of contrast medium when using CT-based attenuation correction in PET.
Ay MR; Zaidi H
Eur J Nucl Med Mol Imaging; 2006 Nov; 33(11):1301-13. PubMed ID: 16622710
[TBL] [Abstract][Full Text] [Related]
16. Impact of time-of-flight PET on quantification errors in MR imaging-based attenuation correction.
Mehranian A; Zaidi H
J Nucl Med; 2015 Apr; 56(4):635-41. PubMed ID: 25745090
[TBL] [Abstract][Full Text] [Related]
17. Reducing metal artifacts in computed tomography caused by hip endoprostheses using a physics-based approach.
Prell D; Kyriakou Y; Kachelrie M; Kalender WA
Invest Radiol; 2010 Nov; 45(11):747-54. PubMed ID: 20661145
[TBL] [Abstract][Full Text] [Related]
18. Joint correction of respiratory motion artifact and partial volume effect in lung/thoracic PET/CT imaging.
Chang G; Chang T; Pan T; Clark JW; Mawlawi OR
Med Phys; 2010 Dec; 37(12):6221-32. PubMed ID: 21302779
[TBL] [Abstract][Full Text] [Related]
19. Does reducing CT artifacts from dental implants influence the PET interpretation in PET/CT studies of oral cancer and head and neck cancer?
Nahmias C; Lemmens C; Faul D; Carlson E; Long M; Blodgett T; Nuyts J; Townsend D
J Nucl Med; 2008 Jul; 49(7):1047-52. PubMed ID: 18552154
[TBL] [Abstract][Full Text] [Related]
20. Qualitative and quantitative assessment of metal artifacts arising from implantable cardiac pacing devices in oncological PET/CT studies: a phantom study.
Ay MR; Mehranian A; Abdoli M; Ghafarian P; Zaidi H
Mol Imaging Biol; 2011 Dec; 13(6):1077-87. PubMed ID: 21203854
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]