291 related articles for article (PubMed ID: 17524687)
1. Low temperature probe for dynamic nuclear polarization and multiple-pulse solid-state NMR.
Cho H; Baugh J; Ryan CA; Cory DG; Ramanathan C
J Magn Reson; 2007 Aug; 187(2):242-50. PubMed ID: 17524687
[TBL] [Abstract][Full Text] [Related]
2. Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900 MHz.
Gor'kov PL; Chekmenev EY; Li C; Cotten M; Buffy JJ; Traaseth NJ; Veglia G; Brey WW
J Magn Reson; 2007 Mar; 185(1):77-93. PubMed ID: 17174130
[TBL] [Abstract][Full Text] [Related]
3. High-field dynamic nuclear polarization in aqueous solutions.
Prandolini MJ; Denysenkov VP; Gafurov M; Endeward B; Prisner TF
J Am Chem Soc; 2009 May; 131(17):6090-2. PubMed ID: 19361195
[TBL] [Abstract][Full Text] [Related]
4. A Dynamic Nuclear Polarization spectrometer at 95 GHz/144 MHz with EPR and NMR excitation and detection capabilities.
Feintuch A; Shimon D; Hovav Y; Banerjee D; Kaminker I; Lipkin Y; Zibzener K; Epel B; Vega S; Goldfarb D
J Magn Reson; 2011 Apr; 209(2):136-41. PubMed ID: 21296015
[TBL] [Abstract][Full Text] [Related]
5. A multi-sample 94 GHz dissolution dynamic-nuclear-polarization system.
Batel M; Krajewski M; Weiss K; With O; Däpp A; Hunkeler A; Gimersky M; Pruessmann KP; Boesiger P; Meier BH; Kozerke S; Ernst M
J Magn Reson; 2012 Jan; 214(1):166-74. PubMed ID: 22142831
[TBL] [Abstract][Full Text] [Related]
6. Liquid state DNP using a 260 GHz high power gyrotron.
Denysenkov V; Prandolini MJ; Gafurov M; Sezer D; Endeward B; Prisner TF
Phys Chem Chem Phys; 2010 Jun; 12(22):5786-90. PubMed ID: 20461255
[TBL] [Abstract][Full Text] [Related]
7. High-field DNP and ENDOR with a novel multiple-frequency resonance structure.
Weis V; Bennati M; Rosay M; Bryant JA; Griffin RG
J Magn Reson; 1999 Sep; 140(1):293-9. PubMed ID: 10479576
[TBL] [Abstract][Full Text] [Related]
8. Cross polarization, radio frequency field homogeneity, and circuit balancing in high field solid state NMR probes.
Paulson EK; Martin RW; Zilm KW
J Magn Reson; 2004 Dec; 171(2):314-23. PubMed ID: 15546758
[TBL] [Abstract][Full Text] [Related]
9. Portable X-band system for solution state dynamic nuclear polarization.
Armstrong BD; Lingwood MD; McCarney ER; Brown ER; Blümler P; Han S
J Magn Reson; 2008 Apr; 191(2):273-81. PubMed ID: 18226943
[TBL] [Abstract][Full Text] [Related]
10. Solid-state nitrogen-14 nuclear magnetic resonance enhanced by dynamic nuclear polarization using a gyrotron.
Vitzthum V; Caporini MA; Bodenhausen G
J Magn Reson; 2010 Jul; 205(1):177-9. PubMed ID: 20488737
[TBL] [Abstract][Full Text] [Related]
11. Optimal control design of NMR and dynamic nuclear polarization experiments using monotonically convergent algorithms.
Maximov II; Tosner Z; Nielsen NC
J Chem Phys; 2008 May; 128(18):184505. PubMed ID: 18532824
[TBL] [Abstract][Full Text] [Related]
12. In situ temperature jump high-frequency dynamic nuclear polarization experiments: enhanced sensitivity in liquid-state NMR spectroscopy.
Joo CG; Hu KN; Bryant JA; Griffin RG
J Am Chem Soc; 2006 Jul; 128(29):9428-32. PubMed ID: 16848479
[TBL] [Abstract][Full Text] [Related]
13. An open volume, high isolation, radio frequency surface coil system for pulsed magnetic resonance.
Curto CA; Placidi G; Sotgiu A; Alecci M
J Magn Reson; 2004 Dec; 171(2):353-8. PubMed ID: 15546763
[TBL] [Abstract][Full Text] [Related]
14. Remote tuning of NMR probe circuits.
Kodibagkar VD; Conradi MS
J Magn Reson; 2000 May; 144(1):53-7. PubMed ID: 10783273
[TBL] [Abstract][Full Text] [Related]
15. Reduction of RF-induced sample heating with a scroll coil resonator structure for solid-state NMR probes.
Stringer JA; Bronnimann CE; Mullen CG; Zhou DH; Stellfox SA; Li Y; Williams EH; Rienstra CM
J Magn Reson; 2005 Mar; 173(1):40-8. PubMed ID: 15705511
[TBL] [Abstract][Full Text] [Related]
16. A spectrometer designed for 6.7 and 14.1 T DNP-enhanced solid-state MAS NMR using quasi-optical microwave transmission.
Pike KJ; Kemp TF; Takahashi H; Day R; Howes AP; Kryukov EV; MacDonald JF; Collis AE; Bolton DR; Wylde RJ; Orwick M; Kosuga K; Clark AJ; Idehara T; Watts A; Smith GM; Newton ME; Dupree R; Smith ME
J Magn Reson; 2012 Feb; 215():1-9. PubMed ID: 22218011
[TBL] [Abstract][Full Text] [Related]
17. Solid-state dynamic nuclear polarization at 263 GHz: spectrometer design and experimental results.
Rosay M; Tometich L; Pawsey S; Bader R; Schauwecker R; Blank M; Borchard PM; Cauffman SR; Felch KL; Weber RT; Temkin RJ; Griffin RG; Maas WE
Phys Chem Chem Phys; 2010 Jun; 12(22):5850-60. PubMed ID: 20449524
[TBL] [Abstract][Full Text] [Related]
18. Design, construction, and validation of a 1-mm triple-resonance high-temperature-superconducting probe for NMR.
Brey WW; Edison AS; Nast RE; Rocca JR; Saha S; Withers RS
J Magn Reson; 2006 Apr; 179(2):290-3. PubMed ID: 16423543
[TBL] [Abstract][Full Text] [Related]
19. Design and characterization of a W-band system for modulated DNP experiments.
Guy ML; Zhu L; Ramanathan C
J Magn Reson; 2015 Dec; 261():11-8. PubMed ID: 26524649
[TBL] [Abstract][Full Text] [Related]
20. A high-pressure, high-resolution NMR probe for experiments at 500 MHz.
Ballard L; Yu A; Reiner C; Jonas J
J Magn Reson; 1998 Jul; 133(1):190-3. PubMed ID: 9654485
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]