These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 17530610)

  • 21. [Continuous free-flap monitoring with tissue-oxygen measurements: experiences of the last years].
    Kamolz LP; Schrögendorfer KF; Giovanoli P; Koller R; Frey M
    Handchir Mikrochir Plast Chir; 2002 May; 34(3):195-200. PubMed ID: 12203156
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Three-year experience using near infrared spectroscopy tissue oximetry monitoring of free tissue transfers.
    Steele MH
    Ann Plast Surg; 2011 May; 66(5):540-5. PubMed ID: 21301288
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A prospective analysis of free flap monitoring techniques: physical examination, external Doppler, implantable Doppler, and tissue oximetry.
    Lohman RF; Langevin CJ; Bozkurt M; Kundu N; Djohan R
    J Reconstr Microsurg; 2013 Jan; 29(1):51-6. PubMed ID: 23147246
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Near-infrared spectroscopy in autologous breast reconstruction.
    Colwell AS; Craft RO
    Clin Plast Surg; 2011 Apr; 38(2):301-7. PubMed ID: 21620154
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Application of near-infrared spectroscopy to postoperative monitoring of flap in plastic surgery].
    Li Y; Ding HS; Huang L; Tian FH; Cai ZG
    Guang Pu Xue Yu Guang Pu Fen Xi; 2005 Mar; 25(3):377-80. PubMed ID: 16013310
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Free flap pulse oximetry utilizing reflectance photoplethysmography.
    Zaman T; Kyriacou PA; Pal SK
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():4046-9. PubMed ID: 24110620
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of a non-invasive monitoring method for free flap breast reconstruction using laser doppler flowmetrie and tissue spectrophotometry.
    Rothenberger J; Amr A; Schaller HE; Rahmanian-Schwarz A
    Microsurgery; 2013 Jul; 33(5):350-7. PubMed ID: 23436443
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Vascular pedicle avulsion in free flap breast reconstruction: a case of diep flap salvage following early avulsion of venous anastomosis and literature review.
    Lykoudis EG; Ziogas DE; Papanikolaou GE
    Microsurgery; 2010; 30(3):233-7. PubMed ID: 20091858
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Application of near infrared spectroscopy in monitoring blood oxygen saturation of fibula flaps].
    Shan XF; Cai ZG; Yu GY; Li Y; Ding HS
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2008 Jul; 43(7):398-401. PubMed ID: 19031814
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The False Positive Rate of Transcutaneous Tissue Oximetry Alarms in Microvascular Breast Reconstruction Rises after 24 Hours.
    Tran PC; DeBrock W; Lester ME; Hartman BC; Socas J; Hassanein AH
    J Reconstr Microsurg; 2021 Jun; 37(5):453-557. PubMed ID: 33129214
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Regional Oxygen Saturation Index: A Novel Criterion for Free Flap Assessment Using Tissue Oximetry.
    Akita S; Mitsukawa N; Tokumoto H; Kubota Y; Kuriyama M; Sasahara Y; Yamaji Y; Satoh K
    Plast Reconstr Surg; 2016 Sep; 138(3):510e-518e. PubMed ID: 27556627
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A postoperative analysis of perfusion dynamics in deep inferior epigastric perforator flap breast reconstruction: a noninvasive quantitative measurement of flap oxygen saturation and blood flow.
    Rahmanian-Schwarz A; Rothenberger J; Amr A; Jaminet P; Schaller HE
    Ann Plast Surg; 2012 Nov; 69(5):535-9. PubMed ID: 21629069
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The transverse myocutaneous gracilis flap: technical refinements.
    Fattah A; Figus A; Mathur B; Ramakrishnan VV
    J Plast Reconstr Aesthet Surg; 2010 Feb; 63(2):305-13. PubMed ID: 19131289
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Validation of a noninvasive neonatal optical cerebral oximeter in veno-venous ECMO patients with a cephalad catheter.
    Rais-Bahrami K; Rivera O; Short BL
    J Perinatol; 2006 Oct; 26(10):628-35. PubMed ID: 16900202
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Perforator flap breast reconstruction after unsatisfactory implant reconstruction.
    Levine SM; Lester ME; Fontenot B; Allen RJ
    Ann Plast Surg; 2011 May; 66(5):513-7. PubMed ID: 21301299
    [TBL] [Abstract][Full Text] [Related]  

  • 36. First-in-human pilot study of a spatial frequency domain oxygenation imaging system.
    Gioux S; Mazhar A; Lee BT; Lin SJ; Tobias AM; Cuccia DJ; Stockdale A; Oketokoun R; Ashitate Y; Kelly E; Weinmann M; Durr NJ; Moffitt LA; Durkin AJ; Tromberg BJ; Frangioni JV
    J Biomed Opt; 2011 Aug; 16(8):086015. PubMed ID: 21895327
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The sGAP flap: rare exception or second choice in autologous breast reconstruction?
    Baumeister S; Werdin F; Peek A
    J Reconstr Microsurg; 2010 May; 26(4):251-8. PubMed ID: 20169527
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients.
    Tortoriello TA; Stayer SA; Mott AR; McKenzie ED; Fraser CD; Andropoulos DB; Chang AC
    Paediatr Anaesth; 2005 Jun; 15(6):495-503. PubMed ID: 15910351
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Treatment and outcome of complications after free flap-plasty].
    Giunta R; Geisweid A; Lukas B; Feller AM
    Handchir Mikrochir Plast Chir; 2000 May; 32(3):176-80. PubMed ID: 10929556
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Near-infrared spectroscopy measures tissue oxygenation in free flaps for breast reconstruction.
    Colwell AS; Wright L; Karanas Y
    Plast Reconstr Surg; 2008 May; 121(5):344e-345e. PubMed ID: 18453956
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.