BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 17534921)

  • 1. Self-calibration method for radial GRAPPA/k-t GRAPPA.
    Huang F; Vijayakumar S; Li Y; Hertel S; Reza S; Duensing GR
    Magn Reson Med; 2007 Jun; 57(6):1075-85. PubMed ID: 17534921
    [TBL] [Abstract][Full Text] [Related]  

  • 2. k-t GRAPPA: a k-space implementation for dynamic MRI with high reduction factor.
    Huang F; Akao J; Vijayakumar S; Duensing GR; Limkeman M
    Magn Reson Med; 2005 Nov; 54(5):1172-84. PubMed ID: 16193468
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A radial self-calibrated (RASCAL) generalized autocalibrating partially parallel acquisition (GRAPPA) method using weight interpolation.
    Codella NC; Spincemaille P; Prince M; Wang Y
    NMR Biomed; 2011 Aug; 24(7):844-54. PubMed ID: 21834008
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Generalized GRAPPA operators for wider spiral bands: rapid self-calibrated parallel reconstruction for variable density spiral MRI.
    Lin W; Börnert P; Huang F; Duensing GR; Reykowski A
    Magn Reson Med; 2011 Oct; 66(4):1067-78. PubMed ID: 21469186
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reconstruction of undersampled non-Cartesian data sets using pseudo-Cartesian GRAPPA in conjunction with GROG.
    Seiberlich N; Breuer F; Heidemann R; Blaimer M; Griswold M; Jakob P
    Magn Reson Med; 2008 May; 59(5):1127-37. PubMed ID: 18429026
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Self-calibrated trajectory estimation and signal correction method for robust radial imaging using GRAPPA operator gridding.
    Deshmane A; Blaimer M; Breuer F; Jakob P; Duerk J; Seiberlich N; Griswold M
    Magn Reson Med; 2016 Feb; 75(2):883-96. PubMed ID: 25765372
    [TBL] [Abstract][Full Text] [Related]  

  • 7. GRAPPA operator for wider radial bands (GROWL) with optimally regularized self-calibration.
    Lin W; Huang F; Li Y; Reykowski A
    Magn Reson Med; 2010 Sep; 64(3):757-66. PubMed ID: 20806377
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Improving GRAPPA using cross-sampled autocalibration data.
    Wang H; Liang D; King KF; Nagarsekar G; Chang Y; Ying L
    Magn Reson Med; 2012 Apr; 67(4):1042-53. PubMed ID: 22135234
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Self-calibrated GRAPPA method for 2D and 3D radial data.
    Arunachalam A; Samsonov A; Block WF
    Magn Reson Med; 2007 May; 57(5):931-8. PubMed ID: 17457884
    [TBL] [Abstract][Full Text] [Related]  

  • 10. GRAPPA reconstruction with spatially varying calibration of self-constraint.
    Xu L; Guo L; Liu X; Kang L; Chen W; Feng Y
    Magn Reson Med; 2015 Oct; 74(4):1057-69. PubMed ID: 25311235
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Self-calibrating GRAPPA operator gridding for radial and spiral trajectories.
    Seiberlich N; Breuer F; Blaimer M; Jakob P; Griswold M
    Magn Reson Med; 2008 Apr; 59(4):930-5. PubMed ID: 18383296
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Artifact and noise suppression in GRAPPA imaging using improved k-space coil calibration and variable density sampling.
    Park J; Zhang Q; Jellus V; Simonetti O; Li D
    Magn Reson Med; 2005 Jan; 53(1):186-93. PubMed ID: 15690518
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Generalized autocalibrating partially parallel acquisitions (GRAPPA).
    Griswold MA; Jakob PM; Heidemann RM; Nittka M; Jellus V; Wang J; Kiefer B; Haase A
    Magn Reson Med; 2002 Jun; 47(6):1202-10. PubMed ID: 12111967
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A nonlinear regularization strategy for GRAPPA calibration.
    Bydder M; Jung Y
    Magn Reson Imaging; 2009 Jan; 27(1):137-41. PubMed ID: 18583080
    [TBL] [Abstract][Full Text] [Related]  

  • 15. k-space inherited parallel acquisition (KIPA): application on dynamic magnetic resonance imaging thermometry.
    Guo JY; Kholmovski EG; Zhang L; Jeong EK; Parker DL
    Magn Reson Imaging; 2006 Sep; 24(7):903-15. PubMed ID: 16916708
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High temporal resolution retrospective motion correction with radial parallel imaging.
    Lin W; Huang F; Duensing GR; Reykowski A
    Magn Reson Med; 2012 Apr; 67(4):1097-105. PubMed ID: 21842499
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improve GRAPPA with cross-sampled ACS lines and nonlinear kernel model.
    Wang X; Wang H; Zhou J
    Biomed Mater Eng; 2014; 24(1):1101-8. PubMed ID: 24212002
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Direct parallel image reconstructions for spiral trajectories using GRAPPA.
    Heidemann RM; Griswold MA; Seiberlich N; Krüger G; Kannengiesser SA; Kiefer B; Wiggins G; Wald LL; Jakob PM
    Magn Reson Med; 2006 Aug; 56(2):317-26. PubMed ID: 16826608
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Regularization method for phase-constrained parallel MRI.
    Blaimer M; Jakob PM; Breuer FA
    Magn Reson Med; 2014 Jul; 72(1):166-71. PubMed ID: 23904349
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High-pass GRAPPA: an image support reduction technique for improved partially parallel imaging.
    Huang F; Li Y; Vijayakumar S; Hertel S; Duensing GR
    Magn Reson Med; 2008 Mar; 59(3):642-9. PubMed ID: 18219633
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.