These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 17541714)

  • 1. Reliability of continuous pulse contour cardiac output measurement during hemodynamic instability.
    Johansson A; Chew M
    J Clin Monit Comput; 2007 Aug; 21(4):237-42. PubMed ID: 17541714
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Validation of a new arterial pulse contour-based cardiac output device.
    de Waal EE; Kalkman CJ; Rex S; Buhre WF
    Crit Care Med; 2007 Aug; 35(8):1904-9. PubMed ID: 17581493
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy and precision of calibrated arterial pulse contour analysis in patients with subarachnoid hemorrhage requiring high-dose vasopressor therapy: a prospective observational clinical trial.
    Metzelder SM; Coburn M; Stoppe C; Fries M; Simon TP; Reinges MH; Höllig A; Rossaint R; Marx G; Rex S
    Crit Care; 2014 Feb; 18(1):R25. PubMed ID: 24499533
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration.
    Bein B; Meybohm P; Cavus E; Renner J; Tonner PH; Steinfath M; Scholz J; Doerges V
    Anesth Analg; 2007 Jul; 105(1):107-13. PubMed ID: 17578965
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reliability of continuous cardiac output measurement during intra-abdominal hypertension relies on repeated calibrations: an experimental animal study.
    Gruenewald M; Renner J; Meybohm P; Höcker J; Scholz J; Bein B
    Crit Care; 2008; 12(5):R132. PubMed ID: 18957114
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pulse contour cardiac output analysis in a piglet model of severe hemorrhagic shock.
    Piehl MD; Manning JE; McCurdy SL; Rhue TS; Kocis KC; Cairns CB; Cairns BA
    Crit Care Med; 2008 Apr; 36(4):1189-95. PubMed ID: 18401255
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of norepinephrine dosage and calibration frequency on accuracy of pulse contour-derived cardiac output.
    Gruenewald M; Meybohm P; Renner J; Broch O; Caliebe A; Weiler N; Steinfath M; Scholz J; Bein B
    Crit Care; 2011; 15(1):R22. PubMed ID: 21241481
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of continuous cardiac output measurements in patients after cardiac surgery.
    Mielck F; Buhre W; Hanekop G; Tirilomis T; Hilgers R; Sonntag H
    J Cardiothorac Vasc Anesth; 2003 Apr; 17(2):211-6. PubMed ID: 12698404
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [The effect of blood volume change on the accuracy of pulse contour cardiac output].
    Yao D; Xu J; Li C; Fu Y; Li Y; Tan D; Shao S; Liu D; Zhu H; Guo S; Yu X
    Zhonghua Wai Ke Za Zhi; 2015 Jul; 53(7):547-52. PubMed ID: 26359081
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reliability of Pulse Contour Cardiac Output Analysis in a Piglet Model of Multi-step Intra-abdominal Hypertension.
    Zheng Y; Li W; Sui F; Ma H; Wang H; Wang Z
    J Surg Res; 2021 Jan; 257():545-553. PubMed ID: 32927321
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Continuous measurement of cardiac output with pulse contour analysis].
    Irlbeck M; Forst H; Briegel J; Haller M; Peter K
    Anaesthesist; 1995 Jul; 44(7):493-500. PubMed ID: 7661336
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of thermodilution, lithium dilution, and pulse contour analysis for the measurement of cardiac output in 3 different hemodynamic states in dogs.
    Morgaz J; Granados Mdel M; Muñoz-Rascón P; Dominguez JM; Fernández-Sarmiento JA; Gómez-Villamandos RJ; Navarrete R
    J Vet Emerg Crit Care (San Antonio); 2014; 24(5):562-70. PubMed ID: 25142925
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Importance of re-calibration time on pulse contour analysis agreement with thermodilution measurements of cardiac output: a retrospective analysis of intensive care unit patients.
    Scully CG; Gomatam S; Forrest S; Strauss DG
    J Clin Monit Comput; 2016 Oct; 30(5):577-86. PubMed ID: 26285740
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correlation between cardiac output measured by the femoral arterial thermodilution technique pulmonary arterial and that measured by contour pulse analysis in a paediatric animal model.
    López-Herce J; Rupérez M; Sánchez C; García C; García E
    J Clin Monit Comput; 2006 Feb; 20(1):19-23. PubMed ID: 16508822
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of beat-to-beat cardiac output monitoring by pulse contour analysis in hemodynamical unstable patients.
    Gödje O; Friedl R; Hannekum A
    Med Sci Monit; 2001; 7(6):1344-50. PubMed ID: 11687755
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Semi-invasive measurement of cardiac output based on pulse contour: a review and analysis.
    Schlöglhofer T; Gilly H; Schima H
    Can J Anaesth; 2014 May; 61(5):452-79. PubMed ID: 24643474
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Trending ability and limitations of transpulmonary thermodilution and pulse contour cardiac output measurement in cats as a model for pediatric patients.
    Kutter AP; Bektas RN; Hofer CK; Larenza Menzies MP; Bettschart-Wolfensberger R
    J Clin Monit Comput; 2015 Jun; 29(3):377-83. PubMed ID: 25228023
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting.
    Buhre W; Weyland A; Kazmaier S; Hanekop GG; Baryalei MM; Sydow M; Sonntag H
    J Cardiothorac Vasc Anesth; 1999 Aug; 13(4):437-40. PubMed ID: 10468257
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cardiac output by arterial pulse contour: reliability under hemodynamic derangements.
    Romagnoli S; Romano SM; Bevilacqua S; Ciappi F; Lazzeri C; Peris A; Dini D; Gelsomino S
    Interact Cardiovasc Thorac Surg; 2009 Jun; 8(6):642-6. PubMed ID: 19299422
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cardiac output by femoral arterial thermodilution-calibrated pulse contour analysis during liver transplantation: comparison with pulmonary artery thermodilution.
    Grigorov Tzenkov I; Arnal Velasco D; Perez Peña JM; Olmedilla Arnal L; Garutti Martínez I; Sanz Fernández J
    Transplant Proc; 2003 Aug; 35(5):1920-2. PubMed ID: 12962849
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.