BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

308 related articles for article (PubMed ID: 17544555)

  • 1. Investigation into the effect of varus-valgus orientation on load transfer in the resurfaced femoral head: a multi-femur finite element analysis.
    Radcliffe IA; Taylor M
    Clin Biomech (Bristol, Avon); 2007 Aug; 22(7):780-6. PubMed ID: 17544555
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Investigation into the affect of cementing techniques on load transfer in the resurfaced femoral head: a multi-femur finite element analysis.
    Radcliffe IA; Taylor M
    Clin Biomech (Bristol, Avon); 2007 May; 22(4):422-30. PubMed ID: 17270328
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bone remodelling inside a cemented resurfaced femoral head.
    Gupta S; New AM; Taylor M
    Clin Biomech (Bristol, Avon); 2006 Jul; 21(6):594-602. PubMed ID: 16542761
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of femur size and morphology on load transfer in the resurfaced femoral head: A large scale, multi-subject finite element study.
    Bryan R; Nair PB; Taylor M
    J Biomech; 2012 Jul; 45(11):1952-8. PubMed ID: 22704609
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The biomechanical consequence of insufficient femoral component lateralization and exposed cancellous bone in hip resurfacing arthroplasty.
    Olsen M; Davis ET; Whyne CM; Zdero R; Schemitsch EH
    J Biomech Eng; 2010 Aug; 132(8):081011. PubMed ID: 20670060
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Surgical variables affect the mechanics of a hip resurfacing system.
    Long JP; Bartel DL
    Clin Orthop Relat Res; 2006 Dec; 453():115-22. PubMed ID: 17016222
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Femoral neck fracture following hip resurfacing: the effect of alignment of the femoral component.
    Davis ET; Olsen M; Zdero R; Waddell JP; Schemitsch EH
    J Bone Joint Surg Br; 2008 Nov; 90(11):1522-7. PubMed ID: 18978277
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of positioning and notching of resurfaced femurs on femoral neck strength: a biomechanical test.
    Nabavi A; Yeoh KM; Shidiac L; Appleyard R; Gillies RM; Turnbull A
    J Orthop Surg (Hong Kong); 2009 Apr; 17(1):47-50. PubMed ID: 19398793
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of primary stability on load transfer and bone remodelling within the uncemented resurfaced femur.
    Pal B; Gupta S
    Proc Inst Mech Eng H; 2011 Jun; 225(6):549-61. PubMed ID: 22034739
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of suitable sample sizes for multi-patient based finite element studies.
    Radcliffe IA; Prescott P; Man HS; Taylor M
    Med Eng Phys; 2007 Dec; 29(10):1065-72. PubMed ID: 17218146
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A mechanical analysis of femoral resurfacing implantation for osteonecrosis of the femoral head.
    Sakagoshi D; Kabata T; Umemoto Y; Sakamoto J; Tomita K
    J Arthroplasty; 2010 Dec; 25(8):1282-9. PubMed ID: 19879726
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The impact of proximal femoral morphology on failure strength with a mid-head resection short-stem hip arthroplasty.
    Olsen M; Al Saied M; Morison Z; Sellan M; Waddell JP; Schemitsch EH
    Proc Inst Mech Eng H; 2014 Dec; 228(12):1275-80. PubMed ID: 25515228
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of varus/valgus malalignment on bone strains in the proximal tibia after TKR: an explicit finite element study.
    Perillo-Marcone A; Taylor M
    J Biomech Eng; 2007 Feb; 129(1):1-11. PubMed ID: 17227092
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A numerical study of failure mechanisms in the cemented resurfaced femur: effects of interface characteristics and bone remodelling.
    Pal B; Gupta S; New AM
    Proc Inst Mech Eng H; 2009 May; 223(4):471-84. PubMed ID: 19499837
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of the change in stem length on the load transfer and bone remodelling for a cemented resurfaced femur.
    Pal B; Gupta S; New AM
    J Biomech; 2010 Nov; 43(15):2908-14. PubMed ID: 20728891
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of interface condition and implant design on bone remodelling and failure risk for the resurfaced femoral head.
    Rothstock S; Uhlenbrock A; Bishop N; Laird L; Nassutt R; Morlock M
    J Biomech; 2011 Jun; 44(9):1646-53. PubMed ID: 21511258
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Design considerations for ceramic resurfaced femoral head: effect of interface characteristics on failure mechanisms.
    Pal B; Gupta S; New AM
    Comput Methods Biomech Biomed Engin; 2010; 13(2):143-55. PubMed ID: 19787497
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The development of a computational stress analysis of the femoral head. Mapping tensile, compressive, and shear stress for the varus and valgus positions.
    Brown TD; Ferguson AB
    J Bone Joint Surg Am; 1978 Jul; 60(5):619-29. PubMed ID: 681380
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Changes in femur stress after hip resurfacing arthroplasty: response to physiological loads.
    Little JP; Taddei F; Viceconti M; Murray DW; Gill HS
    Clin Biomech (Bristol, Avon); 2007 May; 22(4):440-8. PubMed ID: 17257719
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.