BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

193 related articles for article (PubMed ID: 17549031)

  • 1. Covalently attached vancomycin provides a nanoscale antibacterial surface.
    Antoci V; Adams CS; Parvizi J; Ducheyne P; Shapiro IM; Hickok NJ
    Clin Orthop Relat Res; 2007 Aug; 461():81-7. PubMed ID: 17549031
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Vancomycin covalently bonded to titanium alloy prevents bacterial colonization.
    Antoci V; King SB; Jose B; Parvizi J; Zeiger AR; Wickstrom E; Freeman TA; Composto RJ; Ducheyne P; Shapiro IM; Hickok NJ; Adams CS
    J Orthop Res; 2007 Jul; 25(7):858-66. PubMed ID: 17415753
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Vancomycin bound to Ti rods reduces periprosthetic infection: preliminary study.
    Antoci V; Adams CS; Hickok NJ; Shapiro IM; Parvizi J
    Clin Orthop Relat Res; 2007 Aug; 461():88-95. PubMed ID: 17549034
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Vancomycin covalently bonded to titanium beads kills Staphylococcus aureus.
    Jose B; Antoci V; Zeiger AR; Wickstrom E; Hickok NJ
    Chem Biol; 2005 Sep; 12(9):1041-8. PubMed ID: 16183028
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Controlled release of vancomycin from thin sol-gel films on titanium alloy fracture plate material.
    Radin S; Ducheyne P
    Biomaterials; 2007 Mar; 28(9):1721-9. PubMed ID: 17184835
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Vancomycin derivative photopolymerized to titanium kills S. epidermidis.
    Lawson MC; Bowman CN; Anseth KS
    Clin Orthop Relat Res; 2007 Aug; 461():96-105. PubMed ID: 17549033
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Local protection for surgical implants.
    Lucke M
    Chem Biol; 2005 Sep; 12(9):958-9; discussion 1041-8. PubMed ID: 16183019
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hip arthroplasty infection with heterogeneous vancomycin-resistant Staphylococcus aureus.
    Zeller V; Kitzis MD; Graff W; Mamoudy P; Desplaces N
    Scand J Infect Dis; 2006; 38(10):934-8. PubMed ID: 17008244
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Covalent bonding of vancomycin to Ti6Al4V alloy pins provides long-term inhibition of Staphylococcus aureus colonization.
    Edupuganti OP; Antoci V; King SB; Jose B; Adams CS; Parvizi J; Shapiro IM; Zeiger AR; Hickok NJ; Wickstrom E
    Bioorg Med Chem Lett; 2007 May; 17(10):2692-6. PubMed ID: 17369042
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prophylaxis of infection and effects on osseointegration using a tobramycin-periapatite coating on titanium implants--an experimental study in the rabbit.
    Moojen DJ; Vogely HC; Fleer A; Nikkels PG; Higham PA; Verbout AJ; Castelein RM; Dhert WJ
    J Orthop Res; 2009 Jun; 27(6):710-6. PubMed ID: 19025776
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dalbavancin compared with vancomycin for prevention of Staphylococcus aureus colonization of devices in vivo.
    Darouiche RO; Mansouri MD
    J Infect; 2005 Apr; 50(3):206-9. PubMed ID: 15780414
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Vancomycin-supplemented cancellous bone allografts in hip revision surgery.
    Buttaro M; Comba F; Piccaluga F
    Clin Orthop Relat Res; 2007 Aug; 461():74-80. PubMed ID: 17483727
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Covalent Immobilization of Enoxacin onto Titanium Implant Surfaces for Inhibiting Multiple Bacterial Species Infection and In Vivo Methicillin-Resistant Staphylococcus aureus Infection Prophylaxis.
    Nie B; Long T; Ao H; Zhou J; Tang T; Yue B
    Antimicrob Agents Chemother; 2017 Jan; 61(1):. PubMed ID: 27799220
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Staphylococcus aureus Prosthetic Joint Infection Is Prevented by a Fluorine- and Phosphorus-Doped Nanostructured Ti-6Al-4V Alloy Loaded With Gentamicin and Vancomycin.
    Auñón Á; Esteban J; Doadrio AL; Boiza-Sánchez M; Mediero A; Eguibar-Blázquez D; Cordero-Ampuero J; Conde A; Arenas MÁ; de-Damborenea JJ; Aguilera-Correa JJ
    J Orthop Res; 2020 Mar; 38(3):588-597. PubMed ID: 31608498
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reduction of postoperative spinal implant infection using gentamicin microspheres.
    Stall AC; Becker E; Ludwig SC; Gelb D; Poelstra KA
    Spine (Phila Pa 1976); 2009 Mar; 34(5):479-83. PubMed ID: 19247168
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The inhibition of Staphylococcus epidermidis biofilm formation by vancomycin-modified titanium alloy and implications for the treatment of periprosthetic infection.
    Antoci V; Adams CS; Parvizi J; Davidson HM; Composto RJ; Freeman TA; Wickstrom E; Ducheyne P; Jungkind D; Shapiro IM; Hickok NJ
    Biomaterials; 2008 Dec; 29(35):4684-90. PubMed ID: 18814909
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Significant Suppression of
    Zhang B; Braun BM; Skelly JD; Ayers DC; Song J
    ACS Appl Mater Interfaces; 2019 Aug; 11(32):28641-28647. PubMed ID: 31313901
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Development of reduced vancomycin susceptibility in methicillin-susceptible Staphylococcus aureus.
    Pillai SK; Wennersten C; Venkataraman L; Eliopoulos GM; Moellering RC; Karchmer AW
    Clin Infect Dis; 2009 Oct; 49(8):1169-74. PubMed ID: 19769538
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Electrical signals guided entrapment and controlled release of antibiotics on titanium surface.
    Shi X; Wu H; Li Y; Wei X; Du Y
    J Biomed Mater Res A; 2013 May; 101(5):1373-8. PubMed ID: 23077102
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Decreased Staphylococcus epidermis adhesion and increased osteoblast functionality on antibiotic-loaded titania nanotubes.
    Popat KC; Eltgroth M; Latempa TJ; Grimes CA; Desai TA
    Biomaterials; 2007 Nov; 28(32):4880-8. PubMed ID: 17697708
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.