These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

485 related articles for article (PubMed ID: 17550021)

  • 1. [Ear thermometer not an adequate alternative to rectal thermometer. A comparative study shows big temperature discrepancies of ear temperature measurements ].
    Duberg T; Lundholm C; Holmberg H
    Lakartidningen; 2007 May 9-15; 104(19):1479-82. PubMed ID: 17550021
    [No Abstract]   [Full Text] [Related]  

  • 2. [Can ear temperature measurement be used in a hospital?].
    Nordås TG; Leiren S; Hansen KS
    Tidsskr Nor Laegeforen; 2005 Oct; 125(20):2763-5. PubMed ID: 16244675
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [The ear thermometer; not a good replacement for the rectal thermometer].
    Van Berkel M; Jooren MC; Timmermans A; van der Velde EA
    Ned Tijdschr Geneeskd; 1998 Sep; 142(38):2102-5. PubMed ID: 9856224
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Infrared tympanic thermometry compared to mercury thermometers].
    Valle PC; Kildahl-Andersen O; Steinvoll K
    Tidsskr Nor Laegeforen; 2000 Jan; 120(1):15-7. PubMed ID: 10815472
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Evaluation of ear temperature measurements in a geriatric department].
    Christensen PM; Christensen VB; Matzen LE
    Ugeskr Laeger; 1998 Aug; 160(36):5175-7. PubMed ID: 9741272
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Reading children's temperatures with the tympanic infrared thermometer and the rectal mercury thermometer: equally good results in the emergency room].
    Draaisma JM; van Lemmen RJ; de Jong AA; Doesburg W
    Ned Tijdschr Geneeskd; 1997 May; 141(19):938-41. PubMed ID: 9340539
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Measurement of fever in children--is infrared tympanic thermometry reliable?].
    Banitalebi H; Bangstad HJ
    Tidsskr Nor Laegeforen; 2002 Nov; 122(28):2700-1. PubMed ID: 12523088
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparing mercury-in-glass, tympanic and disposable thermometers in measuring body temperature in healthy young people.
    Khorshid L; Eşer I; Zaybak A; Yapucu U
    J Clin Nurs; 2005 Apr; 14(4):496-500. PubMed ID: 15807757
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Temperature measurement in critically ill adults: a comparison of tympanic and oral methods.
    Giuliano KK; Giuliano AJ; Scott SS; MacLachlan E; Pysznik E; Elliot S; Woytowicz D
    Am J Crit Care; 2000 Jul; 9(4):254-61. PubMed ID: 10888148
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Rectal thermometers still best for body temperature measurement. Comparative study of tympanic and oral thermometers].
    Edling L; Carlsson R; Magnuson A; Holmberg H
    Lakartidningen; 2009 Oct 14-20; 106(42):2680-3. PubMed ID: 19967946
    [No Abstract]   [Full Text] [Related]  

  • 11. Exercise-induced hyperthermia may prevent accurate core temperature measurement by tympanic membrane thermometer.
    Yeo S; Scarbough M
    J Nurs Meas; 1996; 4(2):143-51. PubMed ID: 9170781
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of three methods of temperature measurement in hypothermic, euthermic, and hyperthermic dogs.
    Greer RJ; Cohn LA; Dodam JR; Wagner-Mann CC; Mann FA
    J Am Vet Med Assoc; 2007 Jun; 230(12):1841-8. PubMed ID: 17571987
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reliability of a tympanic thermometer in measuring temperatures in children after minor ear surgery.
    Pandey A; Ingrams DR; Jones M; Raman R; Marks ND
    J Laryngol Otol; 2006 May; 120(5):375-7. PubMed ID: 16696875
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of tympanic temperature readings in children under 6 years of age.
    Lanham DM; Walker B; Klocke E; Jennings M
    Pediatr Nurs; 1999; 25(1):39-42. PubMed ID: 10335248
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Validity of the tympanic infrared thermometer in geriatric inpatients].
    Baeyens H; De Dobbeleer G; Baeyens JP
    Tijdschr Gerontol Geriatr; 2001 Oct; 32(5):206-9. PubMed ID: 11732370
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [The ear thermometer: not a good replacement for the rectal thermometer].
    Voerman HJ
    Ned Tijdschr Geneeskd; 1998 Nov; 142(46):2538-9. PubMed ID: 10028346
    [No Abstract]   [Full Text] [Related]  

  • 17. Measurement accuracy of fever by tympanic and axillary thermometry.
    Devrim I; Kara A; Ceyhan M; Tezer H; Uludağ AK; Cengiz AB; Yiğitkanl I; Seçmeer G
    Pediatr Emerg Care; 2007 Jan; 23(1):16-9. PubMed ID: 17228215
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Questions regarding conclusions in article on tympanic temperature readings.
    Trombley J
    Pediatr Nurs; 1999; 25(6):619-20; author reply 620. PubMed ID: 12024380
    [No Abstract]   [Full Text] [Related]  

  • 19. Supralingual temperatures compared to tympanic and rectal temperatures.
    Beckstrand RL; Wilshaw R; Moran S; Schaalje GB
    Pediatr Nurs; 1996; 22(5):436-8. PubMed ID: 9087077
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Temperature measurement: comparison of non-invasive methods used in adult critical care.
    Farnell S; Maxwell L; Tan S; Rhodes A; Philips B
    J Clin Nurs; 2005 May; 14(5):632-9. PubMed ID: 15840078
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 25.