These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 17550205)

  • 41. Compact piezoelectric stacked actuators for high power applications.
    Yao K; Uchino K; Xu Y; Dong S; Lim LC
    IEEE Trans Ultrason Ferroelectr Freq Control; 2000; 47(4):819-25. PubMed ID: 18238614
    [TBL] [Abstract][Full Text] [Related]  

  • 42. 2-Step Drop Impact Analysis of a Miniature Mobile Haptic Actuator Considering High Strain Rate and Damping Effects.
    Choi B; Choi H; Kang YS; Jeon Y; Lee MG
    Micromachines (Basel); 2019 Apr; 10(4):. PubMed ID: 31018608
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Compact vibration isolation and suspension for Australian International Gravitational Observatory: local control system.
    Dumas JC; Barriga P; Zhao C; Ju L; Blair DG
    Rev Sci Instrum; 2009 Nov; 80(11):114502. PubMed ID: 19947744
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Note: A novel rotary actuator driven by only one piezoelectric actuator.
    Huang H; Fu L; Zhao H; Shi C; Ren L; Li J; Qu H
    Rev Sci Instrum; 2013 Sep; 84(9):096105. PubMed ID: 24089880
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Step consistency active control method for inertial piezoelectric actuator using embedded strain gauges.
    Cheng J; Deng J; Liu Y; Zhang S; Lu F; Tian X; Chen W
    Rev Sci Instrum; 2021 Dec; 92(12):125005. PubMed ID: 34972430
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Velocity feedback control method of low-frequency electromagnetic vibration exciter based on Kalman filter estimation.
    Li W; Cui J; Bian X; Zou L
    Rev Sci Instrum; 2023 Mar; 94(3):035006. PubMed ID: 37012748
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Flat acoustic sources with frequency response correction based on feedback and feed-forward distributed control.
    Ho JH; Berkhoff AP
    J Acoust Soc Am; 2015 Apr; 137(4):2080-8. PubMed ID: 25920858
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Damping actions of the neuromuscular system with inertial loads: human flexor pollicis longus muscle.
    Lin DC; Rymer WZ
    J Neurophysiol; 2001 Mar; 85(3):1059-66. PubMed ID: 11247976
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Response of the seated human body to whole-body vertical vibration: biodynamic responses to mechanical shocks.
    Zhou Z; Griffin MJ
    Ergonomics; 2017 Mar; 60(3):333-346. PubMed ID: 27206993
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Smart panel with active damping units. Implementation of decentralized control.
    Díaz CG; Paulitsch C; Gardonio P
    J Acoust Soc Am; 2008 Aug; 124(2):898-910. PubMed ID: 18681582
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Pneumatic active suspension system for a one-wheel car model using fuzzy reasoning and a disturbance observer.
    Yoshimura T; Takagi A
    J Zhejiang Univ Sci; 2004 Sep; 5(9):1060-8. PubMed ID: 15323000
    [TBL] [Abstract][Full Text] [Related]  

  • 52. A voice coil actuator driven active vibration isolation system with the consideration of flexible modes.
    Park K; Choi D; Ozer A; Kim S; Lee Y; Joo D
    Rev Sci Instrum; 2008 Jun; 79(6):065106. PubMed ID: 18601436
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Control of inertial acoustic cavitation in pulsed sonication using a real-time feedback loop system.
    Desjouy C; Poizat A; Gilles B; Inserra C; Bera JC
    J Acoust Soc Am; 2013 Aug; 134(2):1640-6. PubMed ID: 23927204
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Smart panels with velocity feedback control systems using triangularly shaped strain actuators.
    Gardonio P; Elliott SJ
    J Acoust Soc Am; 2005 Apr; 117(4 Pt 1):2046-64. PubMed ID: 15898647
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Design and performance testing of an ultrasonic linear motor with dual piezoelectric actuators.
    Smithmaitrie P; Suybangdum P; Laoratanakul P; Muensit N
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 May; 59(5):1033-42. PubMed ID: 22622989
    [TBL] [Abstract][Full Text] [Related]  

  • 56. A family of saturated controllers for UWMRs.
    Moreno-Valenzuela J; Montoya-Villegas L; Pérez-Alcocer R; Sandoval J
    ISA Trans; 2020 May; 100():495-509. PubMed ID: 31980208
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Development of a motion-controlled in vitro elbow testing system.
    Dunning CE; Gordon KD; King GJ; Johnson JA
    J Orthop Res; 2003 May; 21(3):405-11. PubMed ID: 12706012
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Decentralized harmonic active vibration control of a flexible plate using piezoelectric actuator-sensor pairs.
    Baudry M; Micheau P; Berry A
    J Acoust Soc Am; 2006 Jan; 119(1):262-77. PubMed ID: 16454282
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Asymmetric Hysteresis Modeling Approach Featuring "Inertial System + Shape Function" for Magnetostrictive Actuators.
    Si ZY; Bai X'; Qian LJ
    Materials (Basel); 2020 Jun; 13(11):. PubMed ID: 32517028
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Duplex PD inertial damping control paradigm for active power decoupling of grid-tied virtual synchronous generator.
    Wang S; Li J; Riaz S; Zaman H; Hao P; Luo Y; Mohammad AS; Al-Ahmadi AA; Ullah N
    Math Biosci Eng; 2022 Aug; 19(12):12031-12057. PubMed ID: 36653985
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.