87 related articles for article (PubMed ID: 1755613)
1. The use of a new portable noncontact tonometer in home tonometry.
Stewart WC; Cascairo MA; Banta R
Ann Ophthalmol; 1991 Oct; 23(10):377-82. PubMed ID: 1755613
[TBL] [Abstract][Full Text] [Related]
2. Glaucoma screening in primary care: the role of noncontact tonometry.
Ralston ME; Choplin NT; Hollenbach KA; Applegate BJ; Henn TW
J Fam Pract; 1992 Jan; 34(1):73-7. PubMed ID: 1728657
[TBL] [Abstract][Full Text] [Related]
3. [Intraocular pressure difference in Goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01"PRA" in glaucoma patients].
Schlote T; Landenberger H
Klin Monbl Augenheilkd; 2005 Feb; 222(2):123-31. PubMed ID: 15719316
[TBL] [Abstract][Full Text] [Related]
4. Pressure phosphene self-tonometry: a comparison with goldmann tonometry in glaucoma patients.
Lam DS; Leung DY; Chiu TY; Fan DS; Cheung EY; Wong TY; Lai JS; Tham CC
Invest Ophthalmol Vis Sci; 2004 Sep; 45(9):3131-6. PubMed ID: 15326131
[TBL] [Abstract][Full Text] [Related]
5. Intraocular pressure difference in Goldmann applanation tonometry versus Perkins hand-held applanation tonometry in overweight patients.
dos Santos MG; Makk S; Berghold A; Eckhardt M; Haas A
Ophthalmology; 1998 Dec; 105(12):2260-3. PubMed ID: 9855157
[TBL] [Abstract][Full Text] [Related]
6. Dynamic contour tonometry for intraocular pressure measurement.
Kamppeter BA; Jonas JB
Am J Ophthalmol; 2005 Aug; 140(2):318-20. PubMed ID: 16086958
[TBL] [Abstract][Full Text] [Related]
7. The influence of central corneal thickness and corneal curvature radius on the intraocular pressure as measured by different tonometers: noncontact and goldmann applanation tonometers.
Harada Y; Hirose N; Kubota T; Tawara A
J Glaucoma; 2008 Dec; 17(8):619-25. PubMed ID: 19092456
[TBL] [Abstract][Full Text] [Related]
8. Agreement of rebound tonometer in measuring intraocular pressure with three types of applanation tonometers.
Nakamura M; Darhad U; Tatsumi Y; Fujioka M; Kusuhara A; Maeda H; Negi A
Am J Ophthalmol; 2006 Aug; 142(2):332-4. PubMed ID: 16876523
[TBL] [Abstract][Full Text] [Related]
9. A comparison of intraocular pressure measurements with the XPERT noncontact tonometer and Goldmann applanation tonometry.
Popovich KS; Shields MB
J Glaucoma; 1997 Feb; 6(1):44-6. PubMed ID: 9075080
[TBL] [Abstract][Full Text] [Related]
10. Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry*.
van der Jagt LH; Jansonius NM
Ophthalmic Physiol Opt; 2005 Sep; 25(5):429-35. PubMed ID: 16101949
[TBL] [Abstract][Full Text] [Related]
11. [Diurnal variation of ocular pressure in open-angle glaucoma with telemonitoring].
Antal S; Jürgens C; Grossjohann R; Tost FH
Klin Monbl Augenheilkd; 2009 Mar; 226(3):168-75. PubMed ID: 19294587
[TBL] [Abstract][Full Text] [Related]
12. Effect of latanoprost on the diurnal variations in the intraocular and ocular perfusion pressure in normal tension glaucoma.
Ishibashi S; Hirose N; Tawara A; Kubota T
J Glaucoma; 2006 Oct; 15(5):354-7. PubMed ID: 16988595
[TBL] [Abstract][Full Text] [Related]
13. Meta-analysis of 24-hour intraocular pressure studies evaluating the efficacy of glaucoma medicines.
Stewart WC; Konstas AG; Nelson LA; Kruft B
Ophthalmology; 2008 Jul; 115(7):1117-1122.e1. PubMed ID: 18082886
[TBL] [Abstract][Full Text] [Related]
14. [Self-tonometry--technical possibilities and clinical significance].
Draeger J; Groenhoff S
Fortschr Ophthalmol; 1990; 87(6):688-91. PubMed ID: 2086419
[TBL] [Abstract][Full Text] [Related]
15. Estimation of intraocular pressure in rabbits using noncontact tonometer: a comparative evaluation with Schiotz tonometer.
Gupta SK; Saxena R; Agarwal R; Galpalli ND; Srivastava S; Agrawal SS
Methods Find Exp Clin Pharmacol; 2007; 29(6):405-9. PubMed ID: 17922069
[TBL] [Abstract][Full Text] [Related]
16. Clinical comparison of pascal dynamic contour tonometry and goldmann applanation tonometry in asymmetric open-angle glaucoma.
Sullivan-Mee M; Halverson KD; Qualls C
J Glaucoma; 2007 Dec; 16(8):694-9. PubMed ID: 18091457
[TBL] [Abstract][Full Text] [Related]
17. Portable tonometers: a clinical comparison of applanation and indentation devices.
Chiara GF; Semes LP; Potter JW; Cutter GR; Tucker WR
J Am Optom Assoc; 1989 Feb; 60(2):105-10. PubMed ID: 2703651
[TBL] [Abstract][Full Text] [Related]
18. [Measurement of intraocular pressure using the Tono-Pen in comparison with Goldmann applanation tonometry - a clinical study in 100 eyes].
Deuter CM; Schlote T; Hahn GA; Bende T; Derse M
Klin Monbl Augenheilkd; 2002 Mar; 219(3):138-42. PubMed ID: 11987041
[TBL] [Abstract][Full Text] [Related]
19. [Fluctuation of intraocular pressure in 24-hour telemonitoring compared to tonometry during normal office hours].
Jürgens C; Antal S; Henrici K; Grossjohann R; Tost FH
Klin Monbl Augenheilkd; 2009 Jan; 226(1):54-9. PubMed ID: 19173164
[TBL] [Abstract][Full Text] [Related]
20. Clinical evaluation of the pressure phosphene tonometer in patients with glaucoma.
Rietveld E; van den Bremer DA; Völker-Dieben HJ
Br J Ophthalmol; 2005 May; 89(5):537-9. PubMed ID: 15834078
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]