Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 17556204)

  • 1. Failure of an implantable cardioverter-defibrillator to detect sustained ventricular tachycardia: a consequence of the latching phenomenon.
    Altman EJ; Gross JN; Fisher JD; Krumerman A
    Heart Rhythm; 2007 Jun; 4(6):785-7. PubMed ID: 17556204
    [No Abstract]   [Full Text] [Related]  

  • 2. Ventricular oversensing after replacement of an implantable cardioverter-defibrillator.
    Arias MA; Puchol A; Castellanos E; Pachón M; Rodríguez-Padial L
    Pacing Clin Electrophysiol; 2009 Jul; 32(7):925-7. PubMed ID: 19572871
    [No Abstract]   [Full Text] [Related]  

  • 3. Implantable cardioverter-defibrillator discharges despite successful termination of ventricular tachycardia by antitachycardia pacing.
    Ho RT
    Pacing Clin Electrophysiol; 2009 Jun; 32(6):791-3. PubMed ID: 19545344
    [No Abstract]   [Full Text] [Related]  

  • 4. Death due to an implantable cardioverter defibrillator.
    Messali A; Thomas O; Chauvin M; Coumel P; Leenhardt A
    J Cardiovasc Electrophysiol; 2004 Aug; 15(8):953-6. PubMed ID: 15333095
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Interruption of Pacing Following Nonsustained Ventricular Tachycardia in an AAI Programmed Implantable Cardioverter Defibrillator.
    Egan P; Wilkoff BL; Tchou P
    Pacing Clin Electrophysiol; 2015 Sep; 38(9):1082-90. PubMed ID: 26010870
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Repetitive Periodic Atrial Oversensing in a Cardiac Implantable Electrical Defibrillator at 35 Minutes and 50 Minutes Past the Hour: What Is the Diagnosis?
    Hu YL; Kaszala K; Huizar J; Ellenbogen KA; Tan AY
    Pacing Clin Electrophysiol; 2016 Sep; 39(9):1018-21. PubMed ID: 27356808
    [No Abstract]   [Full Text] [Related]  

  • 7. Apparent inappropriate shocks from an implantable cardioverter defibrillator:
    Moore DR; Kok LC; Vijayaraman P
    J Cardiovasc Electrophysiol; 2004 Jan; 15(1):116-7. PubMed ID: 15028086
    [No Abstract]   [Full Text] [Related]  

  • 8. Effects of flecainide therapy on inappropriate shocks and arrhythmias in catecholaminergic polymorphic ventricular tachycardia.
    Jacquemart C; Ould Abderrahmane F; Massin MM
    J Electrocardiol; 2012; 45(6):736-8. PubMed ID: 22672791
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A worrisome experience during testing of an implantable cardioverter defibrillator (ICD).
    Warren J; Elliott L; Perschbacher D
    J Cardiovasc Electrophysiol; 2001 May; 12(5):619-21. PubMed ID: 11386530
    [No Abstract]   [Full Text] [Related]  

  • 10. A worrisome experience during testing of an implantable cardioverter defibrillator (ICD).
    Viskin S
    J Cardiovasc Electrophysiol; 2001 May; 12(5):619. PubMed ID: 11386529
    [No Abstract]   [Full Text] [Related]  

  • 11. Inappropriate implantable cardioverter-defibrillator shock in unusual circumstances.
    Suran MC; Margulescu AD; Siliste C; Vinereanu D
    Acta Cardiol; 2016 Jun; 71(3):369-70. PubMed ID: 27594132
    [No Abstract]   [Full Text] [Related]  

  • 12. Initiation of ventricular tachycardia by interruption of pacemaker-mediated tachycardia in a patient with a dual-chamber implantable cardioverter defibrillator.
    Van Gelder BM; Meijer A; Dekker LR; Bracke FA
    Pacing Clin Electrophysiol; 2009 Sep; 32(9):1227-30. PubMed ID: 19719503
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Case report: Delayed detection of ventricular tachycardia due to intradevice interactions by implantable atrio-ventricular pacer/cardioverter defibrillator.
    Kantharia BK; Padder FA
    J Interv Card Electrophysiol; 2006 Aug; 16(2):135-8. PubMed ID: 17016683
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Failure of an ICD to Deliver Antitachycardia Therapy against Recurrent, Sustained Ventricular Tachycardia: What's the Mechanism?
    Willoughby MC; Diamantakos E; Dorman AK; Pires LA
    Pacing Clin Electrophysiol; 2016 Jan; 39(1):95-8. PubMed ID: 26310862
    [No Abstract]   [Full Text] [Related]  

  • 15. Tracking preference as unusual trigger of pacemaker-mediated tachycardia in a resynchronization device.
    Crea P; Picciolo G; Luzza F
    J Electrocardiol; 2016; 49(4):509-11. PubMed ID: 26976512
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Inappropriate therapy due to triple counting of the ventricular electrogram in a patient with implantable cardioverter-defibrillator.
    Alasti M; Haghjoo M; Alizadeh A; Fazelifar AF; Sadr-Ameli MA
    Heart Rhythm; 2005 Nov; 2(11):1253-5. PubMed ID: 16253917
    [No Abstract]   [Full Text] [Related]  

  • 17. ICD proarrhythmia as a consequence of an interaction with an algorithm to prevent atrial arrhythmias.
    Martínez-Sánchez J; García-Alberola A; Sánchez-Muñoz JJ; Peñafiel-Verdú P; Giner-Caro JA; Valdés-Chávarri M
    Pacing Clin Electrophysiol; 2009 Aug; 32(8):1096-8. PubMed ID: 19659632
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Irregular ventricular tachycardia underdetected by implantable cardioverter defibrillator device.
    Manolis AG; Kourouklis S; Chatzis D; Kouvelas K; Kyriakides Z
    Cardiol J; 2008; 15(3):281-3. PubMed ID: 18651422
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Lead system causing twiddler's syndrome in patients with an implantable cardioverter-defibrillator.
    Bracke F; van Gelder B; Dijkman B; Meijer A
    J Thorac Cardiovasc Surg; 2005 Jan; 129(1):231-2. PubMed ID: 15632856
    [No Abstract]   [Full Text] [Related]  

  • 20. Recurrence of ventricular tachycardia degeneration by low-energy implantable cardioverter-defibrillator shocks: a case report.
    Cagli KE; Guray U; Akpinar I; Sen N; Aras D; Topaloglu S
    J Electrocardiol; 2010; 43(1):68-70. PubMed ID: 19446839
    [TBL] [Abstract][Full Text] [Related]  