BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 17558479)

  • 1. Microvasculatory reaction of skeletal muscle to Ti-15Mo in comparison to well-established titanium alloys.
    Pennekamp PH; Wimmer MA; Eschbach L; Burian B; Koch P; Kraft CN
    J Mater Sci Mater Med; 2007 Oct; 18(10):2053-60. PubMed ID: 17558479
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Short-term microvascular response of striated muscle to cp-Ti, Ti-6Al-4V, and Ti-6Al-7Nb.
    Pennekamp PH; Gessmann J; Diedrich O; Burian B; Wimmer MA; Frauchiger VM; Kraft CN
    J Orthop Res; 2006 Mar; 24(3):531-40. PubMed ID: 16463365
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Microvascular response of striated muscle to common arthroplasty-alloys: A comparative in vivo study with CoCrMo, Ti-6Al-4V, and Ti-6Al-7Nb.
    Kraft CN; Burian B; Diedrich O; Gessmann J; Wimmer MA; Pennekamp PH
    J Biomed Mater Res A; 2005 Oct; 75(1):31-40. PubMed ID: 16078208
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The corrosion behaviour of Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr in protein solutions.
    Khan MA; Williams RL; Williams DF
    Biomaterials; 1999 Apr; 20(7):631-7. PubMed ID: 10208405
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Conjoint corrosion and wear in titanium alloys.
    Khan MA; Williams RL; Williams DF
    Biomaterials; 1999 Apr; 20(8):765-72. PubMed ID: 10353659
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Castability and mechanical properties of Ti-15Mo-5Zr-3Al alloy in dental casting.
    Koizumi H; Ishii T; Okazaki T; Kaketani M; Matsumura H; Yoneyama T
    J Oral Sci; 2018; 60(2):285-292. PubMed ID: 29925713
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparative analysis of corrosion resistance between beta titanium and Ti-6Al-4V alloys: A systematic review.
    Dias Corpa Tardelli J; Bolfarini C; Cândido Dos Reis A
    J Trace Elem Med Biol; 2020 Dec; 62():126618. PubMed ID: 32663743
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The development of Ti alloys for dental implant with high corrosion resistance and mechanical strength.
    Yamazoe J; Nakagawa M; Matono Y; Takeuchi A; Ishikawa K
    Dent Mater J; 2007 Mar; 26(2):260-7. PubMed ID: 17621943
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reduced toxicity and superior cellular response of preosteoblasts to Ti-6Al-7Nb alloy and comparison with Ti-6Al-4V.
    Challa VS; Mali S; Misra RD
    J Biomed Mater Res A; 2013 Jul; 101(7):2083-9. PubMed ID: 23349101
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparative corrosion study of Ti-Ta alloys for dental applications.
    Mareci D; Chelariu R; Gordin DM; Ungureanu G; Gloriant T
    Acta Biomater; 2009 Nov; 5(9):3625-39. PubMed ID: 19508903
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of a niobium-containing titanium alloy on osteoblast behavior in culture.
    Shapira L; Klinger A; Tadir A; Wilensky A; Halabi A
    Clin Oral Implants Res; 2009 Jun; 20(6):578-82. PubMed ID: 19530314
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Additively manufactured Ti-29Nb-21Zr shows improved oxide polarization resistance versus Ti-6Al-4V in inflammatory simulating solution.
    Kurtz MA; Wessinger AC; Mace A; Moreno-Reyes A; Gilbert JL
    J Biomed Mater Res A; 2023 Oct; 111(10):1538-1553. PubMed ID: 37129046
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of a nickel-reduced stainless steel implant on striated muscle microcirculation: a comparative in vivo study.
    Kraft CN; Burian B; Perlick L; Wimmer MA; Wallny T; Schmitt O; Diedrich O
    J Biomed Mater Res; 2001 Dec; 57(3):404-12. PubMed ID: 11523035
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of Tricalcium Magnesium Silicate Coating on the Electrochemical and Biological Behavior of Ti-6Al-4V Alloys.
    Maleki-Ghaleh H; Hafezi M; Hadipour M; Nadernezhad A; Aghaie E; Behnamian Y; Abu Osman NA
    PLoS One; 2015; 10(9):e0138454. PubMed ID: 26383641
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of noble metals alloying additions on the corrosion behaviour of titanium in a fluoride-containing environment.
    Rosalbino F; Delsante S; Borzone G; Scavino G
    J Mater Sci Mater Med; 2012 May; 23(5):1129-37. PubMed ID: 22382735
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the titanium Ti-6Al-7Nb alloy with and without plasma-sprayed hydroxyapatite coating on growth and viability of cultured osteoblast-like cells.
    de Lavos-Valereto IC; Deboni MC; Azambuja N; Marques MM
    J Periodontol; 2002 Aug; 73(8):900-5. PubMed ID: 12211500
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Study on improved tribological properties by alloying copper to CP-Ti and Ti-6Al-4V alloy.
    Wang S; Ma Z; Liao Z; Song J; Yang K; Liu W
    Mater Sci Eng C Mater Biol Appl; 2015 Dec; 57():123-32. PubMed ID: 26354247
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments.
    Nakagawa M; Matono Y; Matsuya S; Udoh K; Ishikawa K
    Biomaterials; 2005 May; 26(15):2239-46. PubMed ID: 15585225
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Spark plasma sintering synthesis of porous nanocrystalline titanium alloys for biomedical applications.
    Nicula R; Lüthen F; Stir M; Nebe B; Burkel E
    Biomol Eng; 2007 Nov; 24(5):564-7. PubMed ID: 17869173
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro and in vivo studies of alkali- and heat-treated Ti-6Al-7Nb and Ti-5Al-2Nb-1Ta alloys for orthopedic implants.
    Tamilselvi S; Raghavendran HB; Srinivasan P; Rajendran N
    J Biomed Mater Res A; 2009 Aug; 90(2):380-6. PubMed ID: 18523948
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.