BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 17558479)

  • 21. The role of titanium implant surface modification with hydroxyapatite nanoparticles in progressive early bone-implant fixation in vivo.
    Lin A; Wang CJ; Kelly J; Gubbi P; Nishimura I
    Int J Oral Maxillofac Implants; 2009; 24(5):808-16. PubMed ID: 19865620
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Microvascular response of striated muscle to metal debris. A comparative in vivo study with titanium and stainless steel.
    Kraft CN; Diedrich O; Burian B; Schmitt O; Wimmer MA
    J Bone Joint Surg Br; 2003 Jan; 85(1):133-41. PubMed ID: 12585592
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Crestal remodelling and osseointegration at surface-modified commercially pure titanium and titanium alloy implants in a canine model.
    Lee J; Hurson S; Tadros H; Schüpbach P; Susin C; Wikesjö UM
    J Clin Periodontol; 2012 Aug; 39(8):781-8. PubMed ID: 22671935
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Striated muscle microvascular response to silver implants: A comparative in vivo study with titanium and stainless steel.
    Kraft CN; Hansis M; Arens S; Menger MD; Vollmar B
    J Biomed Mater Res; 2000 Feb; 49(2):192-9. PubMed ID: 10571905
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Electrochemical corrosion behavior and elasticity properties of Ti-6Al-xFe alloys for biomedical applications.
    Lu J; Zhao Y; Niu H; Zhang Y; Du Y; Zhang W; Huo W
    Mater Sci Eng C Mater Biol Appl; 2016 May; 62():36-44. PubMed ID: 26952395
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Corrosion behavior of pure titanium and titanium alloys in various concentrations of Acidulated Phosphate Fluoride (APF) solutions.
    Matono Y; Nakagawa M; Matsuya S; Ishikawa K; Terada Y
    Dent Mater J; 2006 Mar; 25(1):104-12. PubMed ID: 16706304
    [TBL] [Abstract][Full Text] [Related]  

  • 27. In-vitro and in-vivo evaluation of a new Ti-15Mo-1Bi alloy.
    Lee JW; Lin DJ; Ju CP; Yin HS; Chuang CC; Lin JC
    J Biomed Mater Res B Appl Biomater; 2009 Nov; 91(2):643-650. PubMed ID: 19630058
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Corrosion resistance and in vitro response of laser-deposited Ti-Nb-Zr-Ta alloys for orthopedic implant applications.
    Samuel S; Nag S; Nasrazadani S; Ukirde V; El Bouanani M; Mohandas A; Nguyen K; Banerjee R
    J Biomed Mater Res A; 2010 Sep; 94(4):1251-6. PubMed ID: 20694992
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Hardness and microstructure of Ti-15Mo-5Zr-3Al alloy for dental casting.
    Kochi M; Koizumi H; Murakami M; Kikuchi H; Matsumura H; Yoneyama T
    Acta Odontol Scand; 2011 Nov; 69(6):328-33. PubMed ID: 21426269
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Joint prostheses components of warm-forged and surface treated Ti-6Al-7Nb alloy].
    Semlitsch M; Weber H; Streicher RM; Schön R
    Biomed Tech (Berl); 1991 May; 36(5):112-9. PubMed ID: 1859861
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of an amorphous titania nanotubes coating on the fatigue and corrosion behaviors of the biomedical Ti-6Al-4V and Ti-6Al-7Nb alloys.
    Campanelli LC; Bortolan CC; da Silva PSCP; Bolfarini C; Oliveira NTC
    J Mech Behav Biomed Mater; 2017 Jan; 65():542-551. PubMed ID: 27697716
    [TBL] [Abstract][Full Text] [Related]  

  • 32. In vitro wear assessment of titanium alloy teeth.
    Ohkubo C; Shimura I; Aoki T; Hanatani S; Hosoi T; Okabe T
    J Prosthodont; 2002 Dec; 11(4):263-9. PubMed ID: 12501140
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Exposure effects of endotoxin-free titanium-based wear particles to human osteoblasts.
    Costa BC; Alves AC; Toptan F; Pinto AM; Grenho L; Fernandes MH; Petrovykh DY; Rocha LA; Lisboa-Filho PN
    J Mech Behav Biomed Mater; 2019 Jul; 95():143-152. PubMed ID: 30999211
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Novel production method and in-vitro cell compatibility of porous Ti-6Al-4V alloy disk for hard tissue engineering.
    Bhattarai SR; Khalil KA; Dewidar M; Hwang PH; Yi HK; Kim HY
    J Biomed Mater Res A; 2008 Aug; 86(2):289-99. PubMed ID: 17957720
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The bone tissue compatibility of a new Ti-Nb-Sn alloy with a low Young's modulus.
    Miura K; Yamada N; Hanada S; Jung TK; Itoi E
    Acta Biomater; 2011 May; 7(5):2320-6. PubMed ID: 21316491
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Bone mesenchymal stem cell functions on the hierarchical micro/nanotopographies of the Ti-6Al-7Nb alloy.
    Ren N; Zhang S; Li Y; Shen S; Niu Q; Zhao Y; Kong L
    Br J Oral Maxillofac Surg; 2014 Dec; 52(10):907-12. PubMed ID: 25255783
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The effect of fluoride ions on the corrosion behaviour of Ti metal, and Ti6-Al-7Nb and Ti-6Al-4V alloys in artificial saliva.
    Milošev I; Kapun B; Selih VS
    Acta Chim Slov; 2013; 60(3):543-55. PubMed ID: 24169708
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Electrochemical characterization of MC3T3-E1 cells cultured on γTiAl and Ti-6Al-4V alloys.
    Bueno-Vera JA; Torres-Zapata I; Sundaram PA; Diffoot-Carlo N; Vega-Olivencia CA
    Bioelectrochemistry; 2015 Dec; 106(Pt B):316-27. PubMed ID: 26145813
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Cytotoxicity of commercial and novel binary titanium alloys with and without a surface-reaction layer.
    Watanabe I; Wataha JC; Lockwood PE; Shimizu H; Cai Z; Okabe T
    J Oral Rehabil; 2004 Feb; 31(2):185-9. PubMed ID: 15009605
    [TBL] [Abstract][Full Text] [Related]  

  • 40. An initial study of diffusion bonds between superplastic Ti-6Al-4V for implant dentistry applications.
    Elias KL; Daehn GS; Brantley WA; McGlumphy EA
    J Prosthet Dent; 2007 Jun; 97(6):357-65. PubMed ID: 17618918
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.