1263 related articles for article (PubMed ID: 17558890)
1. Evaluation of methods for trace-element determination with emphasis on their usability in the clinical routine laboratory.
Bolann BJ; Rahil-Khazen R; Henriksen H; Isrenn R; Ulvik RJ
Scand J Clin Lab Invest; 2007; 67(4):353-66. PubMed ID: 17558890
[TBL] [Abstract][Full Text] [Related]
2. Technical and clinical aspects of spectrometric analysis of trace elements in clinical samples.
Chan S; Gerson B; Reitz RE; Sadjadi SA
Clin Lab Med; 1998 Dec; 18(4):615-29. PubMed ID: 9891602
[TBL] [Abstract][Full Text] [Related]
3. [The application of inductively coupled plasma atomic emission spectrometry/mass spectrometry in the trace elements and speciation analysis of traditional Chinese Medicine].
Chen H; Liang P; Hu B; Zhao L; Sun DH; Wang XR
Guang Pu Xue Yu Guang Pu Fen Xi; 2002 Dec; 22(6):1019-24. PubMed ID: 12914188
[TBL] [Abstract][Full Text] [Related]
4. [Inductively coupled plasma atomic emission spectrometry and ICP mass spectrometry].
Yoshinaga J
Nihon Rinsho; 1996 Jan; 54(1):202-6. PubMed ID: 8587191
[TBL] [Abstract][Full Text] [Related]
5. The use of atomic spectroscopy in the pharmaceutical industry for the determination of trace elements in pharmaceuticals.
Lewen N
J Pharm Biomed Anal; 2011 Jun; 55(4):653-61. PubMed ID: 21159460
[TBL] [Abstract][Full Text] [Related]
6. A review of the capabilities of ICP-MS for trace element analysis in body fluids and tissues.
Vanhoe H
J Trace Elem Electrolytes Health Dis; 1993 Sep; 7(3):131-9. PubMed ID: 8155984
[TBL] [Abstract][Full Text] [Related]
7. [Developments in determination of elements using ICP-MS in blood and urine].
Zhang SJ; Zhuo XY; Ma D
Fa Yi Xue Za Zhi; 2012 Dec; 28(6):456-60, 463. PubMed ID: 23484331
[TBL] [Abstract][Full Text] [Related]
8. Inductively coupled plasma mass spectrometry for trace element analysis in the clinical laboratory.
Nuttall KL; Gordon WH; Ash KO
Ann Clin Lab Sci; 1995; 25(3):264-71. PubMed ID: 7605109
[TBL] [Abstract][Full Text] [Related]
9. Isotope ratio determination in boron analysis.
Sah RN; Brown PH
Biol Trace Elem Res; 1998; 66(1-3):39-53. PubMed ID: 10050906
[TBL] [Abstract][Full Text] [Related]
10. Determination of heavy metals in activated charcoals and carbon black for Lyocell fiber production using direct solid sampling high-resolution continuum source graphite furnace atomic absorption and inductively coupled plasma optical emission spectrometry.
Lepri FG; Borges DL; Araujo RG; Welz B; Wendler F; Krieg M; Becker-Ross H
Talanta; 2010 May; 81(3):980-7. PubMed ID: 20298882
[TBL] [Abstract][Full Text] [Related]
11. Enrichment with air-sandwiched method of on-line collection/concentration using chelating resin and simultaneous determination of trace elements by inductively coupled plasma atomic emission spectrometry.
Noguchi O; Oshima M; Motomizu S
Talanta; 2009 Jun; 78(4-5):1235-9. PubMed ID: 19362181
[TBL] [Abstract][Full Text] [Related]
12. Determination of trace elements in lithium niobate crystals by solid sampling and solution-based spectrometry methods.
Bencs L; György K; Kardos M; Osán J; Alföldy B; Varga I; Ajtony Z; Szoboszlai N; Stefánka Z; Széles E; Kovács L
Anal Chim Acta; 2012 May; 726():1-8. PubMed ID: 22541007
[TBL] [Abstract][Full Text] [Related]
13. Comparison of sample preservation methods for clinical trace element analysis by inductively coupled plasma mass spectrometry.
Bornhorst JA; Hunt JW; Urry FM; McMillin GA
Am J Clin Pathol; 2005 Apr; 123(4):578-83. PubMed ID: 15743743
[TBL] [Abstract][Full Text] [Related]
14. Flame and graphite furnace atomic absorption spectrometry for trace element determination in vegetable oils, margarine and butter after sample emulsification.
Ieggli CV; Bohrer D; Do Nascimento PC; De Carvalho LM
Food Addit Contam Part A Chem Anal Control Expo Risk Assess; 2011 May; 28(5):640-8. PubMed ID: 21424962
[TBL] [Abstract][Full Text] [Related]
15. Alcohol and metal determination in alcoholic beverages through high-temperature liquid-chromatography coupled to an inductively coupled plasma atomic emission spectrometer.
Terol A; Paredes E; Maestre SE; Prats S; Todolí JL
J Chromatogr A; 2011 Jun; 1218(22):3439-46. PubMed ID: 21507407
[TBL] [Abstract][Full Text] [Related]
16. Analysis of laboratory animal feed for toxic and essential elements by atomic absorption and inductively coupled argon plasma emission spectrometry.
Blakemore WM; Billedeau SM
J Assoc Off Anal Chem; 1981 Nov; 64(6):1284-90. PubMed ID: 7309650
[TBL] [Abstract][Full Text] [Related]
17. Application of a microwave-based desolvation system for multi-elemental analysis of wine by inductively coupled plasma based techniques.
Grindlay G; Mora J; Maestre S; Gras L
Anal Chim Acta; 2008 Nov; 629(1-2):24-37. PubMed ID: 18940318
[TBL] [Abstract][Full Text] [Related]
18. Enhanced methods for assessment of the trace element composition of Iron Age bone.
Shafer MM; Siker M; Overdier JT; Ramsl PC; Teschler-Nicola M; Farrell PM
Sci Total Environ; 2008 Aug; 401(1-3):144-61. PubMed ID: 18486196
[TBL] [Abstract][Full Text] [Related]
19. Searching the most appropriate sample pretreatment for the elemental analysis of wines by inductively coupled plasma-based techniques.
Gonzálvez A; Armenta S; Pastor A; de la Guardia M
J Agric Food Chem; 2008 Jul; 56(13):4943-54. PubMed ID: 18553915
[TBL] [Abstract][Full Text] [Related]
20. Dietary intake of essential minor and trace elements from Asian diets.
Iyengar GV; Kawamura H; Parr RM; Miah FK; Wang JX; Dang HS; Djojosubroto H; Cho SY; Akher P; Natera ES; Nguyen MS
Food Nutr Bull; 2002 Sep; 23(3 Suppl):124-8. PubMed ID: 12362779
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]