These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

301 related articles for article (PubMed ID: 17559620)

  • 1. Osseointegration of anodized titanium implants under different current voltages: a rabbit study.
    Park KH; Heo SJ; Koak JY; Kim SK; Lee JB; Kim SH; Lim YJ
    J Oral Rehabil; 2007 Jul; 34(7):517-27. PubMed ID: 17559620
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biological responses of anodized titanium implants under different current voltages.
    Choi JW; Heo SJ; Koak JY; Kim SK; Lim YJ; Kim SH; Lee JB
    J Oral Rehabil; 2006 Dec; 33(12):889-97. PubMed ID: 17168931
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Osseointegration of anodized titanium implants coated with fibroblast growth factor-fibronectin (FGF-FN) fusion protein.
    Park JM; Koak JY; Jang JH; Han CH; Kim SK; Heo SJ
    Int J Oral Maxillofac Implants; 2006; 21(6):859-66. PubMed ID: 17190295
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Oxidized titanium screws coated with calcium ions and their performance in rabbit bone.
    Sul YT; Johansson CB; Albrektsson T
    Int J Oral Maxillofac Implants; 2002; 17(5):625-34. PubMed ID: 12381062
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimum surface properties of oxidized implants for reinforcement of osseointegration: surface chemistry, oxide thickness, porosity, roughness, and crystal structure.
    Sul YT; Johansson C; Wennerberg A; Cho LR; Chang BS; Albrektsson T
    Int J Oral Maxillofac Implants; 2005; 20(3):349-59. PubMed ID: 15973946
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Healing response of cortical and cancellous bone around titanium implants.
    Lee JE; Heo SJ; Koak JY; Kim SK; Han CH; Lee SJ
    Int J Oral Maxillofac Implants; 2009; 24(4):655-62. PubMed ID: 19885405
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The removal torque of titanium implant inserted in rabbit femur coated with biomimetic deposited Ca-P coating.
    Fuming H; Guoli Y; Xiaoxiang W; Shifang Z
    J Oral Rehabil; 2008 Oct; 35(10):754-65. PubMed ID: 18466279
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Oxidized, bioactive implants are rapidly and strongly integrated in bone. Part 1--experimental implants.
    Sul YT; Jeong Y; Johansson C; Albrektsson T
    Clin Oral Implants Res; 2006 Oct; 17(5):521-6. PubMed ID: 16958691
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Importance of Ca(2+) modifications for osseointegration of smooth and moderately rough anodized titanium implants - a removal torque and histological evaluation in rabbit.
    Fröjd V; Wennerberg A; Franke Stenport V
    Clin Implant Dent Relat Res; 2012 Oct; 14(5):737-45. PubMed ID: 20977616
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Does surface anodisation of titanium implants change osseointegration and make their extraction from bone any easier?
    Langhoff JD; Mayer J; Faber L; Kaestner SB; Guibert G; Zlinszky K; Auer JA; von Rechenberg B
    Vet Comp Orthop Traumatol; 2008; 21(3):202-10. PubMed ID: 18536845
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Enhanced osteoconductivity of micro-structured titanium implants (XiVE S CELLplus) by addition of surface calcium chemistry: a histomorphometric study in the rabbit femur.
    Park JW; Kim HK; Kim YJ; An CH; Hanawa T
    Clin Oral Implants Res; 2009 Jul; 20(7):684-90. PubMed ID: 19489932
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of a cell adhesion molecule coating on the blasted surface of titanium implants on bone healing in the rabbit femur.
    Park JW; Lee SG; Choi BJ; Suh JY
    Int J Oral Maxillofac Implants; 2007; 22(4):533-41. PubMed ID: 17929513
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The bone response of oxidized bioactive and non-bioactive titanium implants.
    Sul YT; Johansson C; Byon E; Albrektsson T
    Biomaterials; 2005 Nov; 26(33):6720-30. PubMed ID: 15975649
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Removal torque and histomorphometric investigation of 4 different titanium surfaces: an experimental study in the rabbit tibia.
    Cordioli G; Majzoub Z; Piattelli A; Scarano A
    Int J Oral Maxillofac Implants; 2000; 15(5):668-74. PubMed ID: 11055134
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Early bone tissue responses to turned and oxidized implants in the rabbit tibia.
    Burgos PM; Rasmusson L; Meirelles L; Sennerby L
    Clin Implant Dent Relat Res; 2008 Sep; 10(3):181-90. PubMed ID: 18218052
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Osseointegration of two different phosphate ion-containing titanium oxide surfaces in rabbit cancellous bone.
    Park JW
    Clin Oral Implants Res; 2013 Aug; 24 Suppl A100():145-51. PubMed ID: 22251085
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of a novel calcium titanate coating on the osseointegration of blasted endosseous implants in rabbit tibiae.
    Suh JY; Jeung OC; Choi BJ; Park JW
    Clin Oral Implants Res; 2007 Jun; 18(3):362-9. PubMed ID: 17298490
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of a multiphasic anodic spark deposition coating on the improvement of implant osseointegration in the osteopenic trabecular bone of sheep.
    Giavaresi G; Chiesa R; Fini M; Sandrini E
    Int J Oral Maxillofac Implants; 2008; 23(4):659-68. PubMed ID: 18807562
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A histomorphometric analysis of the effects of various surface treatment methods on osseointegration.
    Kim YH; Koak JY; Chang IT; Wennerberg A; Heo SJ
    Int J Oral Maxillofac Implants; 2003; 18(3):349-56. PubMed ID: 12814309
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved retention and bone-tolmplant contact with fluoride-modified titanium implants.
    Ellingsen JE; Johansson CB; Wennerberg A; Holmén A
    Int J Oral Maxillofac Implants; 2004; 19(5):659-66. PubMed ID: 15508981
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.