BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

393 related articles for article (PubMed ID: 17562651)

  • 1. The effects of ionisation density on the glow curve structure of LiF:Mg,Ti (TLD-100): the behaviour of composite glow peak 5 in 'slow-cooled' material.
    Fuks E; Horowitz Y; Oster L; Belaish Y; Shahar BB
    Radiat Prot Dosimetry; 2007; 126(1-4):194-7. PubMed ID: 17562651
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Advanced multistage deconvolution applied to composite glow peak 5 in LiF:Mg,Ti (TLD-100).
    Horowitz YS; Fuks E; Oster L; Podpalov L; Belaish Y; Shachar BB
    Radiat Prot Dosimetry; 2007; 126(1-4):322-5. PubMed ID: 17517677
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optical excitation of LiF:Mg,Ti following alpha and beta irradiation.
    Horowitz YS; Fuks Y; Weiss D; Oster L; Podpalov L; Belaish Y
    Radiat Prot Dosimetry; 2006; 119(1-4):386-9. PubMed ID: 16585263
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pre- and post-irradiation fading of 6LiF:Mg,Ti (TLD-600) exposed to thermal neutrons.
    Vainblat N; German U; Weinstein M; Alfassi ZB
    Radiat Prot Dosimetry; 2007; 126(1-4):318-21. PubMed ID: 17496295
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Response of LiF:Mg,Ti to low energy carbon and oxygen ions.
    Rodríguez-Villafuerte M; Avila O; Buenfil AE; Gamboa-deBuen I; Ruiz CG; Brandan ME
    Radiat Prot Dosimetry; 2006; 119(1-4):106-10. PubMed ID: 16698969
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Properties of the 4.45 eV optical absorption band in LiF:Mg,Ti.
    Nail I; Oster L; Horowitz YS; Biderman S; Belaish Y
    Radiat Prot Dosimetry; 2006; 119(1-4):244-7. PubMed ID: 16644966
    [TBL] [Abstract][Full Text] [Related]  

  • 7. On neutron-gamma mixed field dosimetry with LiF:Mg,Ti at radiation protection dose levels.
    Weinstein M; German U; Alfassi ZB
    Radiat Prot Dosimetry; 2006; 119(1-4):314-8. PubMed ID: 16735561
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Experimental investigation of the 100 keV X-ray dose response of the high-temperature thermoluminescence in LiF:Mg,Ti (TLD-100): theoretical interpretation using the unified interaction model.
    Livingstone J; Horowitz YS; Oster L; Datz H; Lerch M; Rosenfeld A; Horowitz A
    Radiat Prot Dosimetry; 2010 Mar; 138(4):320-33. PubMed ID: 19934115
    [TBL] [Abstract][Full Text] [Related]  

  • 9. LiF:Mg,Cu,P glow curve shape dependence on heating rate.
    Luo LZ; Velbeck KJ; Moscovitch M; Rotunda JE
    Radiat Prot Dosimetry; 2006; 119(1-4):184-90. PubMed ID: 16581930
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measurements of the optical density and the thermoluminescent response of LiF:Mg,Ti exposed to high doses of 60Co gamma rays.
    Montaño-García C; Gamboa-deBuen I
    Radiat Prot Dosimetry; 2006; 119(1-4):230-2. PubMed ID: 16644946
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Search for ionisation density effects in the radiation absorption stage in LiF:Mg,Ti.
    Nail I; Horowitz YS; Oster L; Brandan ME; Rodríguez-Villafuerte M; Buenfil AE; Ruiz-Trejo C; Gamboa-Debuen I; Avila O; Tovar VM; Olko P; Ipe N
    Radiat Prot Dosimetry; 2006; 119(1-4):180-3. PubMed ID: 16644967
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mysteries of LiF TLD response following high ionisation density irradiation: nanodosimetry and track structure theory, dose response and glow curve shapes.
    Horowitz Y; Fuks E; Datz H; Oster L; Livingstone J; Rosenfeld A
    Radiat Prot Dosimetry; 2011 Jun; 145(4):356-72. PubMed ID: 21106636
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ionisation density effects following optical excitation in LiF:Mg, Ti (TLD-100).
    Weiss D; Horowitz Y; Oster L
    Radiat Prot Dosimetry; 2007; 126(1-4):206-9. PubMed ID: 17513854
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The dose-response of Harshaw TLD-700H.
    Velbeck KJ; Luo LZ; Ramlo MJ; Rotunda JE
    Radiat Prot Dosimetry; 2006; 119(1-4):255-8. PubMed ID: 16581931
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Low temperature radioluminescence of LiF:Mg,Cu,P.
    Kurt K; Mathur VK; McKeever SW; Townsend PD; Valberg L
    Radiat Prot Dosimetry; 2006; 119(1-4):134-8. PubMed ID: 16735562
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Study of real time temperature profiles in routine TLD read out--influences of detector thickness and heating rate on glow curve shape.
    Stadtmann H; Hranitzky C; Brasik N
    Radiat Prot Dosimetry; 2006; 119(1-4):310-3. PubMed ID: 16825249
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On fading corrections for LiF:Mg,Ti irradiated by thermal neutrons.
    German U; Weinstein M; Dubinski A; Vainblat N; Alfassi ZB
    Radiat Prot Dosimetry; 2004; 110(1-4):305-8. PubMed ID: 15353664
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Track structure approach to the calculation of peak 5a to peak 5 (TLD-100) relative intensities following heavy charged particle irradiation.
    Horowitz YS; Satinger D; Avila O
    Radiat Prot Dosimetry; 2006; 119(1-4):45-8. PubMed ID: 16644996
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Theoretical and experimental investigation of the f(D)max-(S/S0)max anomaly in LiF:Mg,Ti.
    Biderman S; Oster L; Horowitz YS
    Radiat Prot Dosimetry; 2006; 119(1-4):289-92. PubMed ID: 16644978
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Investigation of the ionisation density dependence of the glow curve characteristics of LIF:MG,TI (TLD-100).
    Horowitz YS; Horowitz A; Oster L; Marino S; Datz H; Margaliot M
    Radiat Prot Dosimetry; 2008; 131(4):406-13. PubMed ID: 18667402
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.