140 related articles for article (PubMed ID: 17566327)
1. Selectivity in reversed-phase separations: general influence of solvent type and mobile phase pH.
Neue UD; Méndez A
J Sep Sci; 2007 May; 30(7):949-63. PubMed ID: 17566327
[TBL] [Abstract][Full Text] [Related]
2. Retention of ionizable compounds in high-performance liquid chromatography. IX. Modelling retention in reversed-phase liquid chromatography as a function of pH and solvent composition with acetonitrile-water mobile phases.
Espinosa S; Bosch E; Rosés M
J Chromatogr A; 2002 Feb; 947(1):47-58. PubMed ID: 11873997
[TBL] [Abstract][Full Text] [Related]
3. Investigation of the effect of mobile phase composition on selectivity using a solvent-triangle based approach in achiral SFC.
Muscat Galea C; Mangelings D; Vander Heyden Y
J Pharm Biomed Anal; 2017 Jan; 132():247-257. PubMed ID: 27776301
[TBL] [Abstract][Full Text] [Related]
4. Impact of methanol and acetonitrile on separations based on pi-pi interactions with a reversed-phase phenyl column.
Yang M; Fazio S; Munch D; Drumm P
J Chromatogr A; 2005 Dec; 1097(1-2):124-9. PubMed ID: 16298191
[TBL] [Abstract][Full Text] [Related]
5. Reversed-phase liquid chromatography system constant database over an extended mobile phase composition range for 25 siloxane-bonded silica-based columns.
Poole CF
J Chromatogr A; 2019 Aug; 1600():112-126. PubMed ID: 31128882
[TBL] [Abstract][Full Text] [Related]
6. Interpretation of the excess adsorption isotherms of organic eluent components on the surface of reversed-phase adsorbents. Effect on the analyte retention.
Kazakevich YV; LoBrutto R; Chan F; Patel T
J Chromatogr A; 2001 Apr; 913(1-2):75-87. PubMed ID: 11355846
[TBL] [Abstract][Full Text] [Related]
7. Mobile phase effects in reversed-phase liquid chromatography: a comparison of acetonitrile/water and methanol/water solvents as studied by molecular simulation.
Rafferty JL; Siepmann JI; Schure MR
J Chromatogr A; 2011 Apr; 1218(16):2203-13. PubMed ID: 21388628
[TBL] [Abstract][Full Text] [Related]
8. Selectivity in reversed-phase separations Influence of the stationary phase.
Neue UD; O'Gara JE; Méndez A
J Chromatogr A; 2006 Sep; 1127(1-2):161-74. PubMed ID: 16806238
[TBL] [Abstract][Full Text] [Related]
9. Unique selectivity of tetrahydrofuran-2-propanol-water ternary mobile phases on a superficially porous particle column in reversed-phase liquid chromatography.
Atapattu SN
J Chromatogr A; 2023 Feb; 1690():463801. PubMed ID: 36702058
[TBL] [Abstract][Full Text] [Related]
10. Chromatographic behaviour in reversed-phase high-performance liquid chromatography with micellar and submicellar mobile phases: effects of the organic modifier.
Fischer J; Jandera P
J Chromatogr B Biomed Appl; 1996 May; 681(1):3-19. PubMed ID: 8798907
[TBL] [Abstract][Full Text] [Related]
11. Could linear solvation energy relationships give insights into chiral recognition mechanisms? 1. Pi-pi and charge interaction in the reversed versus the normal phase mode.
Berthod A; Mitchell CR; Armstrong DW
J Chromatogr A; 2007 Sep; 1166(1-2):61-9. PubMed ID: 17719054
[TBL] [Abstract][Full Text] [Related]
12. Comprehensive investigation of the influence of acidic, basic, and organic mobile phase compositions on bioanalytical assay sensitivity in positive ESI mode LC/MS/MS.
Rainville PD; Smith NW; Cowan D; Plumb RS
J Pharm Biomed Anal; 2012 Feb; 59():138-50. PubMed ID: 22088477
[TBL] [Abstract][Full Text] [Related]
13. Interpretation of the excess adsorption isotherms of organic eluent components on the surface of reversed-phase phenyl modified adsorbents.
Chan F; Yeung LS; LoBrutto R; Kazakevich YV
J Chromatogr A; 2005 Aug; 1082(2):158-65. PubMed ID: 16035357
[TBL] [Abstract][Full Text] [Related]
14. High performance liquid chromatography of selected alkaloids in ion-exchange systems.
Petruczynik A; Waksmundzka-Hajnos M
J Chromatogr A; 2013 Oct; 1311():48-54. PubMed ID: 24007682
[TBL] [Abstract][Full Text] [Related]
15. Analysis of the solvent strength parameter (linear solvent strength model) for isocratic separations in reversed-phase liquid chromatography.
Poole CF; Atapattu SN
J Chromatogr A; 2022 Jul; 1675():463153. PubMed ID: 35609444
[TBL] [Abstract][Full Text] [Related]
16. Comparative study of solvation parameter models accounting the effects of mobile phase composition in reversed-phase liquid chromatography.
Torres-Lapasió JR; Ruiz-Angel MJ; García-Alvarez-Coque MC
J Chromatogr A; 2007 Sep; 1166(1-2):85-96. PubMed ID: 17720177
[TBL] [Abstract][Full Text] [Related]
17. Solvent effects on the retention of oligosaccharides in porous graphitic carbon liquid chromatography.
Melmer M; Stangler T; Premstaller A; Lindner W
J Chromatogr A; 2010 Sep; 1217(39):6092-6. PubMed ID: 20800844
[TBL] [Abstract][Full Text] [Related]
18. Retention of ionisable compounds on high-performance liquid chromatography. XV. Estimation of the pH variation of aqueous buffers with the change of the acetonitrile fraction of the mobile phase.
Subirats X; Bosch E; Rosés M
J Chromatogr A; 2004 Dec; 1059(1-2):33-42. PubMed ID: 15628122
[TBL] [Abstract][Full Text] [Related]
19. Influence of pressure and temperature on the physico-chemical properties of mobile phase mixtures commonly used in high-performance liquid chromatography.
Billen J; Broeckhoven K; Liekens A; Choikhet K; Rozing G; Desmet G
J Chromatogr A; 2008 Nov; 1210(1):30-44. PubMed ID: 18834987
[TBL] [Abstract][Full Text] [Related]
20. Combined column-mobile phase mixture statistical design optimization of high-performance liquid chromatographic analysis of multicomponent systems.
Breitkreitz MC; Jardim IC; Bruns RE
J Chromatogr A; 2009 Feb; 1216(9):1439-49. PubMed ID: 19167715
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]