These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 17567358)

  • 1. Airtraq for awake tracheal intubation.
    Suzuki A; Toyama Y; Iwasaki H; Henderson J
    Anaesthesia; 2007 Jul; 62(7):746-7. PubMed ID: 17567358
    [No Abstract]   [Full Text] [Related]  

  • 2. Optimising tracheal intubation success rate using the Airtraq laryngoscope.
    Dhonneur G; Abdi W; Amathieu R; Ndoko S; Tual L
    Anaesthesia; 2009 Mar; 64(3):315-9. PubMed ID: 19302647
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Awake intubation with Airtraq laryngoscope in a morbidly obese patient.
    Uakritdathikarn T; Asampinawat T; Wanasuwannakul T; Yoosamran B
    J Med Assoc Thai; 2008 Apr; 91(4):564-7. PubMed ID: 18556868
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Airtraq optical laryngoscope: tracheal intubation by novice laryngoscopists.
    Hirabayashi Y; Seo N
    Emerg Med J; 2009 Feb; 26(2):112-3. PubMed ID: 19164621
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of the Airtraq and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation.
    Maharaj CH; Costello JF; Harte BH; Laffey JG
    Anaesthesia; 2008 Feb; 63(2):182-8. PubMed ID: 18211450
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hazards associated with the use of a disposable reinforced tracheal tube.
    Ismail S; Khan FA
    J Coll Physicians Surg Pak; 2005 Mar; 15(3):189-90. PubMed ID: 15808108
    [No Abstract]   [Full Text] [Related]  

  • 7. Optimal size and length of the endotracheal tube for tracheal intubation via supraglottic airway devices.
    Xue FS; Xiong J; Yuan YJ; Wang Q
    Can J Anaesth; 2010 Jun; 57(6):624-5; author reply 625. PubMed ID: 20340057
    [No Abstract]   [Full Text] [Related]  

  • 8. Tracheal tube introducers: choose and use with care.
    Evans H; Hodzovic I; Latto IP
    Anaesthesia; 2010 Aug; 65(8):859. PubMed ID: 20649923
    [No Abstract]   [Full Text] [Related]  

  • 9. Comparison of standard polyvinyl chloride tracheal tubes and straight reinforced tracheal tubes for tracheal intubation through different sizes of the Airtraq laryngoscope in anesthetized and paralyzed patients: a randomized prospective study.
    Dimitriou VK; Zogogiannis ID; Douma AK; Pentilas ND; Liotiri DG; Wachtel MS; Karakitsos D
    Anesthesiology; 2009 Dec; 111(6):1265-70. PubMed ID: 19934870
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endotracheal intubation in patients with cervical spine immobilization: a comparison of macintosh and airtraq laryngoscopes.
    Maharaj CH; Buckley E; Harte BH; Laffey JG
    Anesthesiology; 2007 Jul; 107(1):53-9. PubMed ID: 17585215
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Airtraq laryngoscope in 3 cases of difficult intubation].
    Mongil E; Muñecas A; Ortega LF; Arizaga A
    Rev Esp Anestesiol Reanim; 2007; 54(7):451-3. PubMed ID: 17953345
    [No Abstract]   [Full Text] [Related]  

  • 12. Comparison of the Glidescope and Airtraq optical laryngoscopes in patients undergoing direct microlaryngoscopy.
    Lange M; Frommer M; Redel A; Trautner H; Hampel J; Kranke P; Kehl F; Scholtz LU; Roewer N
    Anaesthesia; 2009 Mar; 64(3):323-8. PubMed ID: 19302649
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A comparison of two techniques for inserting the Airtraq laryngoscope in morbidly obese patients.
    Dhonneur G; Ndoko SK; Amathieu R; Attias A; Housseini LE; Polliand C; Tual L
    Anaesthesia; 2007 Aug; 62(8):774-7. PubMed ID: 17635424
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pentax-AWS (Airway Scope) for awake tracheal intubation.
    Suzuki A; Kunisawa T; Takahata O; Iwasaki H; Nozaki K; Henderson JJ
    J Clin Anesth; 2007 Dec; 19(8):642-3. PubMed ID: 18083485
    [No Abstract]   [Full Text] [Related]  

  • 15. Use of the Airtraq laryngoscope in a model of difficult intubation by prehospital providers not previously trained in laryngoscopy.
    Woollard M; Mannion W; Lighton D; Johns I; O'meara P; Cotton C; Smyth M
    Anaesthesia; 2007 Oct; 62(10):1061-5. PubMed ID: 17845660
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Difficult intubation resolved with the Airtraq laryngoscope].
    Martín Rubio A; García Vicente E; Del Castillo Sanz T; Morón de Miguel C
    Rev Esp Anestesiol Reanim; 2007; 54(7):447-8. PubMed ID: 17953342
    [No Abstract]   [Full Text] [Related]  

  • 17. [Airtraq optical laryngoscope].
    Hirabayashi Y; Otsuka Y; Taira K; Shinohara T; Kikuchi Y; Shimada N; Kono R; Tamai K; Inoue S; Seo N
    Masui; 2008 Aug; 57(8):1026-30. PubMed ID: 18710017
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Frova introducer for tracheal intubation - our comments and experience.
    Umesh G; Jasvinder K
    Anaesthesia; 2008 Nov; 63(11):1260-1; author reply 1261-2. PubMed ID: 19032267
    [No Abstract]   [Full Text] [Related]  

  • 19. Frova introducer: neither a stylet nor simply an introducer.
    Sorbello M; Frova G
    Anaesthesia; 2008 Sep; 63(9):1010-1; author reply 1011-3. PubMed ID: 18699874
    [No Abstract]   [Full Text] [Related]  

  • 20. Chipped rail gear of a lightwand device: a potential complication of tracheal intubation.
    Hosokawa K; Nakajima Y; Hashimoto S
    Anesthesiology; 2008 Aug; 109(2):355; discussion 356. PubMed ID: 18648250
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.