These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
873 related articles for article (PubMed ID: 17579950)
1. An evaluation of capnography monitoring during the apnoea test in brain-dead patients. Vivien B; Amour J; Nicolas-Robin A; Vesque M; Langeron O; Coriat P; Riou B Eur J Anaesthesiol; 2007 Oct; 24(10):868-75. PubMed ID: 17579950 [TBL] [Abstract][Full Text] [Related]
2. Transcutaneous monitoring of partial pressure of carbon dioxide in the elderly patient: a prospective, clinical comparison with end-tidal monitoring. Casati A; Squicciarini G; Malagutti G; Baciarello M; Putzu M; Fanelli A J Clin Anesth; 2006 Sep; 18(6):436-40. PubMed ID: 16980160 [TBL] [Abstract][Full Text] [Related]
3. Accuracy of postoperative end-tidal Pco2 measurements with mainstream and sidestream capnography in non-obese patients and in obese patients with and without obstructive sleep apnea. Kasuya Y; Akça O; Sessler DI; Ozaki M; Komatsu R Anesthesiology; 2009 Sep; 111(3):609-15. PubMed ID: 19672177 [TBL] [Abstract][Full Text] [Related]
4. End tidal carbon dioxide monitoring in spontaneously breathing, nonintubated patients. A clinical comparison between conventional sidestream and microstream capnometers. Casati A; Gallioli G; Passaretta R; Scandroglio M; Bignami E; Torri G Minerva Anestesiol; 2001 Apr; 67(4):161-4. PubMed ID: 11376503 [TBL] [Abstract][Full Text] [Related]
5. Good estimation of arterial carbon dioxide by end-tidal carbon dioxide monitoring in the neonatal intensive care unit. Wu CH; Chou HC; Hsieh WS; Chen WK; Huang PY; Tsao PN Pediatr Pulmonol; 2003 Apr; 35(4):292-5. PubMed ID: 12629627 [TBL] [Abstract][Full Text] [Related]
7. Mainstream end-tidal carbon dioxide monitoring in ventilated neonates. Bhat YR; Abhishek N Singapore Med J; 2008 Mar; 49(3):199-203. PubMed ID: 18363000 [TBL] [Abstract][Full Text] [Related]
8. Arterial to end-tidal carbon dioxide gradient and physiological dead space monitoring during general anaesthesia: effects of patients' position. Casati A; Salvo I; Torri G; Calderini E Minerva Anestesiol; 1997 Jun; 63(6):177-82. PubMed ID: 9374078 [TBL] [Abstract][Full Text] [Related]
9. Predicting dead space ventilation in critically ill patients using clinically available data. Frankenfield DC; Alam S; Bekteshi E; Vender RL Crit Care Med; 2010 Jan; 38(1):288-91. PubMed ID: 19789453 [TBL] [Abstract][Full Text] [Related]
10. End-tidal to arterial carbon dioxide partial pressure difference during craniotomy in anaesthetised patients. Husaini J; Choy YC Med J Malaysia; 2008 Dec; 63(5):384-7. PubMed ID: 19803296 [TBL] [Abstract][Full Text] [Related]
11. Correlation of arterial PCO2 and PETCO2 in prehospital controlled ventilation. Belpomme V; Ricard-Hibon A; Devoir C; Dileseigres S; Devaud ML; Chollet C; Marty J Am J Emerg Med; 2005 Nov; 23(7):852-9. PubMed ID: 16291440 [TBL] [Abstract][Full Text] [Related]
12. Gastric mucosal systemic partial pressure of carbon dioxide (PCO(2)) gradient in experimental endotoxin shock in swine--comparison of two methods. Tenhunen JJ; Uusaro A; Ruokonen E Intensive Care Med; 2001 Dec; 27(12):1923-30. PubMed ID: 11797029 [TBL] [Abstract][Full Text] [Related]
13. [Study on safety of apnea test in clinical determination of brain death]. Ma PL; Yang MS; Li Q; Ou H; Peng Y; Su JW; Zhao JZ Zhongguo Wei Zhong Bing Ji Jiu Yi Xue; 2006 May; 18(5):260-3. PubMed ID: 16700984 [TBL] [Abstract][Full Text] [Related]
14. [The behavior of arterial and mixed venous oxygen and carbon dioxide partial pressure and the pH value during and following intubation apnoea. Studies on the occurrence of the Christiansen-Douglas-Haldane effect]. Merkelbach D; Brandt L; Mertzlufft F Anaesthesist; 1993 Oct; 42(10):691-701. PubMed ID: 8250203 [TBL] [Abstract][Full Text] [Related]
15. Factors affecting the relationship between arterial and end-tidal carbon dioxide pressures in the anaesthetised horse. Rainger JE; Dart CM; Perkins NR Aust Vet J; 2010 Jan; 88(1-2):13-9. PubMed ID: 20148820 [TBL] [Abstract][Full Text] [Related]
16. Evaluation of a new side-stream, low dead space, end-tidal carbon dioxide monitoring system in rats. Beck C; Barthel F; Hahn AM; Vollmer C; Bauer I; Picker O Lab Anim; 2014 Jan; 48(1):1-5. PubMed ID: 24072488 [TBL] [Abstract][Full Text] [Related]
17. The effect of increased apparatus dead space and tidal volumes on carbon dioxide elimination and oxygen saturations in a low-flow anesthesia system. Enekvist BJ; Luttropp HH; Johansson A J Clin Anesth; 2008 May; 20(3):170-4. PubMed ID: 18502358 [TBL] [Abstract][Full Text] [Related]
18. End-tidal carbon dioxide monitoring in very low birth weight infants: correlation and agreement with arterial carbon dioxide. Trevisanuto D; Giuliotto S; Cavallin F; Doglioni N; Toniazzo S; Zanardo V Pediatr Pulmonol; 2012 Apr; 47(4):367-72. PubMed ID: 22102598 [TBL] [Abstract][Full Text] [Related]
19. End tidal carbon dioxide as a predictor of the arterial PCO2 in the emergency department setting. Yosefy C; Hay E; Nasri Y; Magen E; Reisin L Emerg Med J; 2004 Sep; 21(5):557-9. PubMed ID: 15333528 [TBL] [Abstract][Full Text] [Related]
20. A novel method of distal end-tidal CO2 capnography in intubated infants: comparison with arterial CO2 and with proximal mainstream end-tidal CO2. Kugelman A; Zeiger-Aginsky D; Bader D; Shoris I; Riskin A Pediatrics; 2008 Dec; 122(6):e1219-24. PubMed ID: 19029196 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]