These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
365 related articles for article (PubMed ID: 17581158)
1. Automated programs for collection of mononuclear cells and progenitor cells by two separators for peripheral blood progenitor cell transplantation: comparison by a randomized crossover study. Ikeda K; Ohto H; Kanno T; Ogata T; Noji H; Ogawa K; Maruyama Y Transfusion; 2007 Jul; 47(7):1234-40. PubMed ID: 17581158 [TBL] [Abstract][Full Text] [Related]
2. Collection of MNCs and progenitor cells by two separators for PBPC transplantation: a randomized crossover trial. Ikeda K; Ohto H; Nemoto K; Yamamoto G; Kato K; Ogata T; Shichishima T; Maruyama Y Transfusion; 2003 Jun; 43(6):814-9. PubMed ID: 12757534 [TBL] [Abstract][Full Text] [Related]
3. Collection of peripheral progenitor cells: a comparison between Amicus and Cobe-Spectra blood cell separators. Adorno G; Del Proposto G; Palombi F; Bruno A; Ballatore G; Postorino M; Tendas A; Del Poeta G; Isacchi G; Amadori S Transfus Apher Sci; 2004 Apr; 30(2):131-6. PubMed ID: 15062751 [TBL] [Abstract][Full Text] [Related]
4. Peripheral blood progenitor cell collection by two programs for autologous and allogeneic transplantation. Ikeda K; Ohto H; Kanno T; Gonda K; Suzuki Y; Ono T; Saito S; Takahashi H; Kimura S; Harada-Shirado K; Yamauchi H; Hoshino Y; Mashimo Y; Nollet KE; Kikuta A; Ogawa K; Takeishi Y Transfusion; 2014 May; 54(5):1235-42. PubMed ID: 24117442 [TBL] [Abstract][Full Text] [Related]
5. Comparison of the Fenwal Amicus and Fresenius Com.Tec cell separators for autologous peripheral blood progenitor cell collection. Altuntas F; Kocyigit I; Ozturk A; Kaynar L; Sari I; Oztekin M; Solmaz M; Eser B; Cetin M; Unal A Transfus Apher Sci; 2007 Apr; 36(2):159-67. PubMed ID: 17369096 [TBL] [Abstract][Full Text] [Related]
6. Comparing peripheral blood stem cell collection using the COBE Spectra, Haemonetics MCS+, and Baxter Amicus. Wu FY; Heng KK; Salleh RB; Soh TG; Lee JJ; Mah J; Linn YC; Loh Y; Hwang W; Tan LK; Law P; Goh YT Transfus Apher Sci; 2012 Dec; 47(3):345-50. PubMed ID: 23032067 [TBL] [Abstract][Full Text] [Related]
7. PBPC collection techniques: standard versus large volume leukapheresis (LVL) in donors and in patients. Gasová Z; Marinov I; Vodvárková S; Böhmová M; Bhuyian-Ludvíková Z Transfus Apher Sci; 2005 Apr; 32(2):167-76. PubMed ID: 15784451 [TBL] [Abstract][Full Text] [Related]
8. Mobilization and collection of peripheral blood progenitor cells for transplantation. Reddy RL Transfus Apher Sci; 2005 Feb; 32(1):63-72. PubMed ID: 15737875 [TBL] [Abstract][Full Text] [Related]
10. In vitro collection and posttransfusion engraftment characteristics of MNCs obtained by using a new separator for autologous PBPC transplantation. Snyder EL; Baril L; Cooper DL; Min K; Mechanic S; Stoddart L; Burtness B; Seagraves P; Debelak J; Gudino M; McCullough J Transfusion; 2000 Aug; 40(8):961-7. PubMed ID: 10960524 [TBL] [Abstract][Full Text] [Related]
11. Comparison of Amicus and COBE Spectra for allogenic peripheral blood stem cell harvest: Study from tertiary care centre in India. Setia RD; Arora S; Handoo A; Dadu T; Choudhary D; Sharma SK; Kharya G; Khandelwal V; Sachdeva P; Doval D; Bakliwal A; Kapoor M; Bajaj S; Bachchas V; Singh P Transfus Apher Sci; 2017 Jun; 56(3):439-444. PubMed ID: 28528807 [TBL] [Abstract][Full Text] [Related]
12. Factors affecting the efficacy of peripheral blood progenitor cells collections by large-volume leukaphereses with standardized processing volumes. Cassens U; Barth IM; Baumann C; Fischer RJ; Kienast J; Vormoor J; Sibrowski W Transfusion; 2004 Nov; 44(11):1593-602. PubMed ID: 15504165 [TBL] [Abstract][Full Text] [Related]
13. Prospective, paired crossover comparison of multiple, single-needle plateletpheresis procedures with the Amicus and Trima Accel cell separators. Fontana S; Mordasini L; Keller P; Taleghani BM Transfusion; 2006 Nov; 46(11):2004-10. PubMed ID: 17076857 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of an algorithm based on peripheral blood hematopoietic progenitor cell and CD34+ cell concentrations to optimize peripheral blood progenitor cell collection by apheresis. Lefrère F; Zohar S; Beaudier S; Audat F; Ribeil JA; Ghez D; Varet B; Cavazzana-Calvo M; Dal Cortivo L; Letestu R; McIntyre E; Brouzes C Transfusion; 2007 Oct; 47(10):1851-7. PubMed ID: 17880611 [TBL] [Abstract][Full Text] [Related]
15. Prospective randomised comparison of the COBE spectra version 6 and haemonetics MCS(+) cell separators for hematopoietic progenitor cells leucapheresis in patients with multiple myeloma. Abdelkefi A; Maamar M; Torjman L; Ladeb S; Lakhal A; Ben Othman T; Slama H; Jenhani F; Mojaat N; Ben Hamed L; Bouhoula S; Hsairi M; Boukef K; Ben Abdeladhim A J Clin Apher; 2006 Jul; 21(2):111-5. PubMed ID: 16395725 [TBL] [Abstract][Full Text] [Related]
16. Prospective randomized and crossover comparison of two apheresis machines for peripheral blood stem cell collection: a multicenter study. Ikeda K; Minakawa K; Muroi K; Fujiwara SI; Yamada-Fujiwara M; Fujimori Y; Tanosaki R; Ohto H; Transfusion; 2016 Nov; 56(11):2839-2847. PubMed ID: 27572290 [TBL] [Abstract][Full Text] [Related]
17. [Collection of hematopoietic progenitor cells from healthy donors]. Bojanić I; Cepulić BG; Mazić S Acta Med Croatica; 2009 Jun; 63(3):237-44. PubMed ID: 19827352 [TBL] [Abstract][Full Text] [Related]
19. Comparison of hematopoietic progenitor cell collections using the COBE Spectra version 7 and Amicus version 3.1 for patients with AL amyloidosis. Burgstaler EA; Winters JL J Clin Apher; 2011; 26(4):186-94. PubMed ID: 21618597 [TBL] [Abstract][Full Text] [Related]
20. Recommendations for optimized settings of the Amicus Crescendo cell separator for the collection of CD34+ progenitor cells. Hartwig D; Dorn I; Kirchner H; Schlenke P Transfusion; 2004 May; 44(5):758-63. PubMed ID: 15104659 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]