206 related articles for article (PubMed ID: 17581776)
1. Differences among implanted pulse generator waveforms cause variations in the neural response to deep brain stimulation.
Butson CR; McIntyre CC
Clin Neurophysiol; 2007 Aug; 118(8):1889-94. PubMed ID: 17581776
[TBL] [Abstract][Full Text] [Related]
2. Characterization of the stimulus waveforms generated by implantable pulse generators for deep brain stimulation.
Lempka SF; Howell B; Gunalan K; Machado AG; McIntyre CC
Clin Neurophysiol; 2018 Apr; 129(4):731-742. PubMed ID: 29448149
[TBL] [Abstract][Full Text] [Related]
3. Reduced long-term cost and increased patient satisfaction with rechargeable implantable pulse generators for deep brain stimulation.
Hitti FL; Vaughan KA; Ramayya AG; McShane BJ; Baltuch GH
J Neurosurg; 2018 Sep; 131(3):799-806. PubMed ID: 30265199
[TBL] [Abstract][Full Text] [Related]
4. Longevity analysis of currently available deep brain stimulation devices.
Halpern CH; McGill KR; Baltuch GH; Jaggi JL
Stereotact Funct Neurosurg; 2011; 89(1):1-5. PubMed ID: 21124046
[TBL] [Abstract][Full Text] [Related]
5. Rechargeable deep brain stimulation implantable pulse generators in movement disorders: patient satisfaction and conversion parameters.
Waln O; Jimenez-Shahed J
Neuromodulation; 2014 Jul; 17(5):425-30; discussion 430. PubMed ID: 24112630
[TBL] [Abstract][Full Text] [Related]
6. Battery lifetime in pallidal deep brain stimulation for dystonia.
Blahak C; Capelle HH; Baezner H; Kinfe TM; Hennerici MG; Krauss JK
Eur J Neurol; 2011 Jun; 18(6):872-5. PubMed ID: 21159072
[TBL] [Abstract][Full Text] [Related]
7. Sources and effects of electrode impedance during deep brain stimulation.
Butson CR; Maks CB; McIntyre CC
Clin Neurophysiol; 2006 Feb; 117(2):447-54. PubMed ID: 16376143
[TBL] [Abstract][Full Text] [Related]
8. Changing of the guard: reducing infection when replacing neural pacemakers.
Pepper J; Meliak L; Akram H; Hyam J; Milabo C; Candelario J; Foltynie T; Limousin P; Curtis C; Hariz M; Zrinzo L
J Neurosurg; 2017 Apr; 126(4):1165-1172. PubMed ID: 27315022
[TBL] [Abstract][Full Text] [Related]
9. Decreasing battery life in subthalamic deep brain stimulation for Parkinson's disease with repeated replacements: Just a matter of energy delivered?
Israeli-Korn SD; Fay-Karmon T; Tessler S; Yahalom G; Benizri S; Strauss H; Zibly Z; Spiegelmann R; Hassin-Baer S
Brain Stimul; 2019; 12(4):845-850. PubMed ID: 30876884
[TBL] [Abstract][Full Text] [Related]
10. Choice of Implantable Pulse Generators for Deep Brain Stimulation: An Overview of Clinical Practice.
Willems YR; van der Gaag NA; Kho KH; Tveiten ØV; Krüger MT; Jakobs M;
Stereotact Funct Neurosurg; 2023; 101(2):135-145. PubMed ID: 36889299
[TBL] [Abstract][Full Text] [Related]
11. Stimulation Efficiency With Decaying Exponential Waveforms in a Wirelessly Powered Switched-Capacitor Discharge Stimulation System.
Lee HM; Howell B; Grill WM; Ghovanloo M
IEEE Trans Biomed Eng; 2018 May; 65(5):1095-1106. PubMed ID: 28829301
[TBL] [Abstract][Full Text] [Related]
12. Influence of the implanted pulse generator as reference electrode in finite element model of monopolar deep brain stimulation.
Walckiers G; Fuchs B; Thiran JP; Mosig JR; Pollo C
J Neurosci Methods; 2010 Jan; 186(1):90-6. PubMed ID: 19895845
[TBL] [Abstract][Full Text] [Related]
13. Tissue and electrode capacitance reduce neural activation volumes during deep brain stimulation.
Butson CR; McIntyre CC
Clin Neurophysiol; 2005 Oct; 116(10):2490-500. PubMed ID: 16125463
[TBL] [Abstract][Full Text] [Related]
14. Internal Pulse Generators in Deep Brain Stimulation: Rechargeable or Not?
Rizzi M; Messina G; Penner F; D'Ammando A; Muratorio F; Franzini A
World Neurosurg; 2015 Oct; 84(4):1020-9. PubMed ID: 26038334
[TBL] [Abstract][Full Text] [Related]
15. Prediction of implantable pulse generator longevity in deep brain stimulation: limitations and possible solutions in clinical practice.
Stewart CD; Eljamel S
Stereotact Funct Neurosurg; 2011; 89(5):299-304. PubMed ID: 21894059
[TBL] [Abstract][Full Text] [Related]
16. Longevity of Implantable Pulse Generators in Bilateral Deep Brain Stimulation for Movement Disorders.
Niemann M; Schneider GH; Kühn A; Vajkoczy P; Faust K
Neuromodulation; 2018 Aug; 21(6):597-603. PubMed ID: 29265529
[TBL] [Abstract][Full Text] [Related]
17. Surgical Replacement of Implantable Pulse Generators in Deep Brain Stimulation: Adverse Events and Risk Factors in a Multicenter Cohort.
Fytagoridis A; Heard T; Samuelsson J; Zsigmond P; Jiltsova E; Skyrman S; Skoglund T; Coyne T; Silburn P; Blomstedt P
Stereotact Funct Neurosurg; 2016; 94(4):235-239. PubMed ID: 27554079
[TBL] [Abstract][Full Text] [Related]
18. Role of electrode design on the volume of tissue activated during deep brain stimulation.
Butson CR; McIntyre CC
J Neural Eng; 2006 Mar; 3(1):1-8. PubMed ID: 16510937
[TBL] [Abstract][Full Text] [Related]
19. Deep brain stimulation lead-contact heating during 3T MRI: single- versus dual-channel pulse generator configurations.
Nazzaro JM; Klemp JA; Brooks WM; Cook-Wiens G; Mayo MS; Van Acker GM; Lyons KE; Cheney PD
Int J Neurosci; 2014 Mar; 124(3):166-74. PubMed ID: 24000873
[TBL] [Abstract][Full Text] [Related]
20. Stability of symptom control after replacement of impulse generators for deep brain stimulation.
Allert N; Kirsch H; Weirich W; Karbe H
J Neurosurg; 2009 Jun; 110(6):1274-7. PubMed ID: 19267532
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]