These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

209 related articles for article (PubMed ID: 17584729)

  • 1. Pulse amplitude adjustment provides immediate pacemaker longevity gain.
    Zlatanovic N; Kedev S; Gjorgov N; Miletic B; Georgiev A; Kovacevic D; Trajkov I; Kaev M; Borozanov V; Boskov V
    Anadolu Kardiyol Derg; 2007 Jul; 7 Suppl 1():216-8. PubMed ID: 17584729
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Telemetry guided pacemaker programming: impact of output amplitude and the use of low threshold leads on projected pacemaker longevity.
    Schwaab B; Fröhlig G; Schwerdt H; Heisel A; Berg M; Schieffer H
    Pacing Clin Electrophysiol; 1998 Nov; 21(11 Pt 1):2055-63. PubMed ID: 9826856
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [The programming of the pulse amplitude: the effect on the longevity of cardiac pacemakers with high and low inhibition currents].
    Schuchert A; Kuck KH
    Dtsch Med Wochenschr; 1993 Feb; 118(5):129-33. PubMed ID: 8432231
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Role of ventricular Autocapture function in increasing longevity of DDDR pacemakers: a prospective study.
    Boriani G; Rusconi L; Biffi M; Pavia L; Sassara M; Malfitano D; Bongiorni MG; Padeletti L; Filice I; Sanfelici D; Maffei P; Vicentini A; Branzi A
    Europace; 2006 Mar; 8(3):216-20. PubMed ID: 16627443
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Prerequisites for pacemaker electrodes for individual programming of a low stimulation impulse (comparison of an Elgiloy and a steroid-dependent pacemaker electrode)].
    Schuchert A; Kuck KH; Bleifeld W
    Z Kardiol; 1990 Jun; 79(6):403-7. PubMed ID: 2378158
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [A new cardiac pacemaker stimulation technology (autocapture) allows, with unchanged life expectancy, reduction of generator size by half].
    Antretter H; Bonatti J; Cottogni M; Hangler H; Müller LC; Mair P; Dapunt OE
    Acta Med Austriaca; 1996; 23(5):159-64. PubMed ID: 9082745
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [The research of related factors affecting the longevity of double chamber cardiac pacemaker].
    Liu P; Wang SJ; Pan XR; Wang KF; Zhang Y
    Zhonghua Yi Xue Za Zhi; 2005 Aug; 85(31):2214-7. PubMed ID: 16321188
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Present day pacemakers for pulse generator exchange: is 3.5 V a sufficient nominal setting for the pulse amplitude? Thera Pacemaker Study Group.
    Schuchert A; Van Langen H; Michels K; Meinertz T
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1824-7. PubMed ID: 8945049
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reprogramming pacemakers enhances longevity and is cost-effective.
    Crossley GH; Gayle DD; Simmons TW; Haisty WK; Bailey JR; Davis-O'Brien K; Hammon JW; Fitzgerald DM
    Circulation; 1996 Nov; 94(9 Suppl):II245-7. PubMed ID: 8901754
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pulse duration variation and electrode size as factors in pacemaker longevity.
    Furman S; Garvey J; Hurzeler P
    J Thorac Cardiovasc Surg; 1975 Mar; 69(3):382-9. PubMed ID: 1117730
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of automatic threshold capture on pulse generator longevity.
    Chen RH; Chen KP; Wang FZ; Hua W; Zhang S
    Chin Med J (Engl); 2006 Jun; 119(11):925-9. PubMed ID: 16780772
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Influence of internal current and pacing current on pacemaker longevity.
    Schuchert A; Kuck KH
    Pacing Clin Electrophysiol; 1994 Jan; 17(1):13-6. PubMed ID: 7511227
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Do steroid-eluting pacemaker electrodes permit programming at lower pacemaker pulse amplitudes?].
    Schuchert A; Kuck KH; Meinertz T
    Dtsch Med Wochenschr; 1995 Apr; 120(17):593-6. PubMed ID: 7736956
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Effect of programmed safety margin on function time of modern dual chamber pacemakers].
    Schwaab B; Schwerdt H; Fröhlig G; Lawall P; Schieffer H
    Z Kardiol; 1998 May; 87(5):372-7. PubMed ID: 9658552
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pacemaker longevity: are we getting what we are promised?
    Senaratne J; Irwin ME; Senaratne MP
    Pacing Clin Electrophysiol; 2006 Oct; 29(10):1044-54. PubMed ID: 17038135
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The relationship between programmed pacemaker pulse amplitude and the surface electrocardiogram recorded amplitude: application of a new high-bandwidth electrocardiogram system.
    Ricke AD; Swiryn S; Sahakian AV; Petrutiu S; Young B; Rowlandson GI
    J Electrocardiol; 2008; 41(6):526-30. PubMed ID: 18804786
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Reasons and complications of pacemaker replacement operation: clinical analysis of 69 case-times].
    Liu XL; Ren LH; Ye HM
    Zhonghua Yi Xue Za Zhi; 2008 Jul; 88(28):1989-91. PubMed ID: 19062742
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ventricular capture management in pediatric pacing: efficacy and safety.
    Silvetti MS; De Santis A; Grutter G; Di Ciommo V; Drago F
    Ital Heart J; 2005 Sep; 6(9):751-6. PubMed ID: 16212078
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Early pacemaker battery depletion caused by a current leak in the output circuitry: rectification not exchange.
    Roos M; Kobza R; Erne P
    Pacing Clin Electrophysiol; 2007 May; 30(5):705-8. PubMed ID: 17461881
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Permanent pacemaker treatment at Gentofte hospital. A follow-up study with special reference to transvenous electrode complications, generator longevity and control procedures.
    Berning J; Larsen B
    Acta Med Scand Suppl; 1976; 596():35-9. PubMed ID: 1070221
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.