These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 17584904)

  • 41. A peptide-based biological coating for enhanced corrosion resistance of titanium alloy biomaterials in chloride-containing fluids.
    Muruve N; Feng Y; Platnich J; Hassett D; Irvin R; Muruve D; Cheng F
    J Biomater Appl; 2017 Mar; 31(8):1225-1234. PubMed ID: 28274193
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6Al4V substrate.
    Souto RM; Lemus MM; Reis RL
    J Biomed Mater Res A; 2004 Jul; 70(1):59-65. PubMed ID: 15174109
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Electrochemical behavior and corrosion resistance of Ti-15Mo alloy in naturally-aerated solutions, containing chloride and fluoride ions.
    Rodrigues AV; Oliveira NT; dos Santos ML; Guastaldi AC
    J Mater Sci Mater Med; 2015 Jan; 26(1):5323. PubMed ID: 25577207
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Effects of Ca and H2O2 added to RPMI on the fretting corrosion of Ti6Al4V.
    Montague A; Merritt K; Brown S; Payer J
    J Biomed Mater Res; 1996 Dec; 32(4):519-26. PubMed ID: 8953141
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Characterisation of a duplex TiO2/CaP coating on Ti6Al4V for hard tissue replacement.
    Ng BS; Annergren I; Soutar AM; Khor KA; Jarfors AE
    Biomaterials; 2005 Apr; 26(10):1087-95. PubMed ID: 15451628
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Determinants of corrosion resistance of Ti-6Al-4V alloy dental implants in an In Vitro model of peri-implant inflammation.
    Berbel LO; Banczek EDP; Karoussis IK; Kotsakis GA; Costa I
    PLoS One; 2019; 14(1):e0210530. PubMed ID: 30703125
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Commercially pure titanium (cp-Ti) versus titanium alloy (Ti6Al4V) materials as bone anchored implants - Is one truly better than the other?
    Shah FA; Trobos M; Thomsen P; Palmquist A
    Mater Sci Eng C Mater Biol Appl; 2016 May; 62():960-6. PubMed ID: 26952502
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Microstructure and Properties of Nanostructured Coating on Ti6Al4V.
    Jordanovová V; Losertová M; Štencek M; Lukášová T; Simha Martynková G; Peikertová P
    Materials (Basel); 2020 Feb; 13(3):. PubMed ID: 32033268
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Low modulus Ti-Nb-Hf alloy for biomedical applications.
    González M; Peña J; Gil FJ; Manero JM
    Mater Sci Eng C Mater Biol Appl; 2014 Sep; 42():691-5. PubMed ID: 25063170
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Preliminary study on the corrosion resistance, antibacterial activity and cytotoxicity of selective-laser-melted Ti6Al4V-xCu alloys.
    Guo S; Lu Y; Wu S; Liu L; He M; Zhao C; Gan Y; Lin J; Luo J; Xu X; Lin J
    Mater Sci Eng C Mater Biol Appl; 2017 Mar; 72():631-640. PubMed ID: 28024632
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Electrochemical corrosion, wear and cell behavior of ZrO
    Li J; He X; Zhang G; Hang R; Huang X; Tang B; Zhang X
    Bioelectrochemistry; 2018 Jun; 121():105-114. PubMed ID: 29413860
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Cytocompatibility assessment of Ti-Nb-Zr-Si thin film metallic glasses with enhanced osteoblast differentiation for biomedical applications.
    Thanka Rajan S; Bendavid A; Subramanian B
    Colloids Surf B Biointerfaces; 2019 Jan; 173():109-120. PubMed ID: 30273871
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Fabrication of TiO2-SiO2 bioceramic coatings on Ti alloy and its synergetic effect on biocompatibility and corrosion resistance.
    Mumjitha M; Raj V
    J Mech Behav Biomed Mater; 2015 Jun; 46():205-21. PubMed ID: 25817608
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Comparative corrosion study of Ti-Ta alloys for dental applications.
    Mareci D; Chelariu R; Gordin DM; Ungureanu G; Gloriant T
    Acta Biomater; 2009 Nov; 5(9):3625-39. PubMed ID: 19508903
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Multi-material Ti6Al4V & PEEK cellular structures produced by Selective Laser Melting and Hot Pressing: A tribocorrosion study targeting orthopedic applications.
    Bartolomeu F; Buciumeanu M; Costa MM; Alves N; Gasik M; Silva FS; Miranda G
    J Mech Behav Biomed Mater; 2019 Jan; 89():54-64. PubMed ID: 30265866
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Ti-O-N/Ti composite coating on Ti-6Al-4V: surface characteristics, corrosion properties and cellular responses.
    Cao XL; Sun T; Yu Y
    J Mater Sci Mater Med; 2015 Mar; 26(3):144. PubMed ID: 25737126
    [TBL] [Abstract][Full Text] [Related]  

  • 57. In vitro culture of mesenchymal cells onto nanocrystalline hydroxyapatite-coated Ti13Nb13Zr alloy.
    Bigi A; Nicoli-Aldini N; Bracci B; Zavan B; Boanini E; Sbaiz F; Panzavolta S; Zorzato G; Giardino R; Facchini A; Abatangelo G; Cortivo R
    J Biomed Mater Res A; 2007 Jul; 82(1):213-21. PubMed ID: 17266017
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Structural analysis and corrosion studies on an ISO 5832-9 biomedical alloy with TiO2 sol-gel layers.
    Burnat B; Dercz G; Blaszczyk T
    J Mater Sci Mater Med; 2014 Mar; 25(3):623-34. PubMed ID: 24271113
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Electrochemical stability and corrosion resistance of Ti-Mo alloys for biomedical applications.
    Oliveira NT; Guastaldi AC
    Acta Biomater; 2009 Jan; 5(1):399-405. PubMed ID: 18707926
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study.
    Barão VA; Mathew MT; Assunção WG; Yuan JC; Wimmer MA; Sukotjo C
    Clin Oral Implants Res; 2012 Sep; 23(9):1055-62. PubMed ID: 22092540
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.