These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 17587336)

  • 1. Surface area analysis of dental implants using micro-computed tomography.
    Schicho K; Kastner J; Klingesberger R; Seemann R; Enislidis G; Undt G; Wanschitz F; Figl M; Wagner A; Ewers R
    Clin Oral Implants Res; 2007 Aug; 18(4):459-64. PubMed ID: 17587336
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Enhanced osteoconductivity of micro-structured titanium implants (XiVE S CELLplus) by addition of surface calcium chemistry: a histomorphometric study in the rabbit femur.
    Park JW; Kim HK; Kim YJ; An CH; Hanawa T
    Clin Oral Implants Res; 2009 Jul; 20(7):684-90. PubMed ID: 19489932
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Resonance frequency measurements in vivo and related surface properties of magnesium-incorporated, micropatterned and magnesium-incorporated TiUnite, Osseotite, SLA and TiOblast implants.
    Sul YT; Jönsson J; Yoon GS; Johansson C
    Clin Oral Implants Res; 2009 Oct; 20(10):1146-55. PubMed ID: 19719742
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Three-dimensional bone-implant integration profiling using micro-computed tomography.
    Butz F; Ogawa T; Chang TL; Nishimura I
    Int J Oral Maxillofac Implants; 2006; 21(5):687-95. PubMed ID: 17066629
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Navigated flapless transmucosal implant placement in the mandible: a pilot study in 20 patients.
    Wittwer G; Adeyemo WL; Schicho K; Figl M; Enislidis G
    Int J Oral Maxillofac Implants; 2007; 22(5):801-7. PubMed ID: 17974116
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of implant body designs and threaded designs of dental implants: a 3-dimensional finite element analysis.
    Huang HL; Chang CH; Hsu JT; Fallgatter AM; Ko CC
    Int J Oral Maxillofac Implants; 2007; 22(4):551-62. PubMed ID: 17929515
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The use of a computerized tomography-based software program with a flapless surgical technique in implant dentistry: a case report.
    Terzioğlu H; Akkaya M; Ozan O
    Int J Oral Maxillofac Implants; 2009; 24(1):137-42. PubMed ID: 19344037
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loading.
    Lin CL; Wang JC; Ramp LC; Liu PR
    Int J Oral Maxillofac Implants; 2008; 23(1):57-64. PubMed ID: 18416413
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis.
    Baggi L; Cappelloni I; Di Girolamo M; Maceri F; Vairo G
    J Prosthet Dent; 2008 Dec; 100(6):422-31. PubMed ID: 19033026
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The quantitative assessment of peri-implant bone responses using histomorphometry and micro-computed tomography.
    Schouten C; Meijer GJ; van den Beucken JJ; Spauwen PH; Jansen JA
    Biomaterials; 2009 Sep; 30(27):4539-49. PubMed ID: 19500840
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Misfit of implant fixed complete denture following computer-guided surgery.
    Oyama K; Kan JY; Kleinman AS; Runcharassaeng K; Lozada JL; Goodacre CJ
    Int J Oral Maxillofac Implants; 2009; 24(1):124-30. PubMed ID: 19344035
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Human histologic evidence of a connective tissue attachment to a dental implant.
    Nevins M; Nevins ML; Camelo M; Boyesen JL; Kim DM
    Int J Periodontics Restorative Dent; 2008 Apr; 28(2):111-21. PubMed ID: 18546807
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparative histomorphometry and resonance frequency analysis of implants with moderately rough surfaces in a loaded animal model.
    Al-Nawas B; Groetz KA; Goetz H; Duschner H; Wagner W
    Clin Oral Implants Res; 2008 Jan; 19(1):1-8. PubMed ID: 17944964
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correlating implant stability to bone structure.
    Rozé J; Babu S; Saffarzadeh A; Gayet-Delacroix M; Hoornaert A; Layrolle P
    Clin Oral Implants Res; 2009 Oct; 20(10):1140-5. PubMed ID: 19519789
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of implant surface roughness and stiffness of grafted bone on an immediately loaded maxillary implant: a 3D numerical analysis.
    Huang HL; Fuh LJ; Hsu JT; Tu MG; Shen YW; Wu CL
    J Oral Rehabil; 2008 Apr; 35(4):283-90. PubMed ID: 18321264
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Load fatigue performance of four implant-abutment interface designs: effect of torque level and implant system.
    Quek HC; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2008; 23(2):253-62. PubMed ID: 18548921
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [A new X-ray-free measurement method for postoperative 3D-position analysis of navigated inserted implants].
    Stopp S; Lüth T
    Biomed Tech (Berl); 2007 Jun; 52(3):234-42. PubMed ID: 17561784
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Chronological changes in the ultrastructure of titanium-bone interfaces: analysis by light microscopy, transmission electron microscopy, and micro-computed tomography.
    Morinaga K; Kido H; Sato A; Watazu A; Matsuura M
    Clin Implant Dent Relat Res; 2009 Mar; 11(1):59-68. PubMed ID: 18384402
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Surface extraction from multi-material components for metrology using dual energy CT.
    Heinzl C; Kastner J; Gröller E
    IEEE Trans Vis Comput Graph; 2007; 13(6):1520-7. PubMed ID: 17968105
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Stress distribution on external hexagon implant system using 3d finite element analysis.
    Segundo RM; Oshima HM; Silva IN; Júnior LH; Mota EG; Coelho LF
    Acta Odontol Latinoam; 2007; 20(2):79-81. PubMed ID: 18590255
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.