140 related articles for article (PubMed ID: 17588248)
1. Enhanced wear resistance of orthopaedic bearing due to the cross-linking of poly(MPC) graft chains induced by gamma-ray irradiation.
Kyomoto M; Moro T; Miyaji F; Konno T; Hashimoto M; Kawaguchi H; Takatori Y; Nakamura K; Ishihara K
J Biomed Mater Res B Appl Biomater; 2008 Feb; 84(2):320-7. PubMed ID: 17588248
[TBL] [Abstract][Full Text] [Related]
2. Enhanced wear resistance of modified cross-linked polyethylene by grafting with poly(2-methacryloyloxyethyl phosphorylcholine).
Kyomoto M; Moro T; Konno T; Takadama H; Yamawaki N; Kawaguchi H; Takatori Y; Nakamura K; Ishihara K
J Biomed Mater Res A; 2007 Jul; 82(1):10-7. PubMed ID: 17265442
[TBL] [Abstract][Full Text] [Related]
3. Effects of photo-induced graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on physical properties of cross-linked polyethylene in artificial hip joints.
Kyomoto M; Moro T; Konno T; Takadama H; Kawaguchi H; Takatori Y; Nakamura K; Yamawaki N; Ishihara K
J Mater Sci Mater Med; 2007 Sep; 18(9):1809-15. PubMed ID: 17483881
[TBL] [Abstract][Full Text] [Related]
4. Effects of extra irradiation on surface and bulk properties of PMPC-grafted cross-linked polyethylene.
Yamane S; Kyomoto M; Moro T; Watanabe K; Hashimoto M; Takatori Y; Tanaka S; Ishihara K
J Biomed Mater Res A; 2016 Jan; 104(1):37-47. PubMed ID: 26148654
[TBL] [Abstract][Full Text] [Related]
5. Effect of 2-methacryloyloxyethyl phosphorylcholine concentration on photo-induced graft polymerization of polyethylene in reducing the wear of orthopaedic bearing surface.
Kyomoto M; Moro T; Miyaji F; Hashimoto M; Kawaguchi H; Takatori Y; Nakamura K; Ishihara K
J Biomed Mater Res A; 2008 Aug; 86(2):439-47. PubMed ID: 17975818
[TBL] [Abstract][Full Text] [Related]
6. Grafting of poly(2-methacryloyloxyethyl phosphorylcholine) on polyethylene liner in artificial hip joints reduces production of wear particles.
Moro T; Kyomoto M; Ishihara K; Saiga K; Hashimoto M; Tanaka S; Ito H; Tanaka T; Oshima H; Kawaguchi H; Takatori Y
J Mech Behav Biomed Mater; 2014 Mar; 31():100-6. PubMed ID: 23651567
[TBL] [Abstract][Full Text] [Related]
7. Poly(2-methacryloyloxyethyl phosphorylcholine) grafting and vitamin E blending for high wear resistance and oxidative stability of orthopedic bearings.
Kyomoto M; Moro T; Yamane S; Watanabe K; Hashimoto M; Takatori Y; Tanaka S; Ishihara K
Biomaterials; 2014 Aug; 35(25):6677-86. PubMed ID: 24836953
[TBL] [Abstract][Full Text] [Related]
8. Effects of mobility/immobility of surface modification by 2-methacryloyloxyethyl phosphorylcholine polymer on the durability of polyethylene for artificial joints.
Kyomoto M; Moro T; Miyaji F; Hashimoto M; Kawaguchi H; Takatori Y; Nakamura K; Ishihara K
J Biomed Mater Res A; 2009 Aug; 90(2):362-71. PubMed ID: 18521890
[TBL] [Abstract][Full Text] [Related]
9. Cartilage-mimicking, high-density brush structure improves wear resistance of crosslinked polyethylene: a pilot study.
Kyomoto M; Moro T; Takatori Y; Kawaguchi H; Ishihara K
Clin Orthop Relat Res; 2011 Aug; 469(8):2327-36. PubMed ID: 21132412
[TBL] [Abstract][Full Text] [Related]
10. Effect of UV-irradiation intensity on graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on orthopedic bearing substrate.
Kyomoto M; Moro T; Yamane S; Hashimoto M; Takatori Y; Ishihara K
J Biomed Mater Res A; 2014 Sep; 102(9):3012-23. PubMed ID: 24124003
[TBL] [Abstract][Full Text] [Related]
11. Superlubricious surface mimicking articular cartilage by grafting poly(2-methacryloyloxyethyl phosphorylcholine) on orthopaedic metal bearings.
Kyomoto M; Moro T; Iwasaki Y; Miyaji F; Kawaguchi H; Takatori Y; Nakamura K; Ishihara K
J Biomed Mater Res A; 2009 Dec; 91(3):730-41. PubMed ID: 19048637
[TBL] [Abstract][Full Text] [Related]
12. Surface grafting of biocompatible phospholipid polymer MPC provides wear resistance of tibial polyethylene insert in artificial knee joints.
Moro T; Takatori Y; Kyomoto M; Ishihara K; Saiga K; Nakamura K; Kawaguchi H
Osteoarthritis Cartilage; 2010 Sep; 18(9):1174-82. PubMed ID: 20633685
[TBL] [Abstract][Full Text] [Related]
13. Nanomechanical and tribological characterization of the MPC phospholipid polymer photografted onto rough polyethylene implants.
Wang N; Trunfio-Sfarghiu AM; Portinha D; Descartes S; Fleury E; Berthier Y; Rieu JP
Colloids Surf B Biointerfaces; 2013 Aug; 108():285-94. PubMed ID: 23563296
[TBL] [Abstract][Full Text] [Related]
14. Influences of dehydration and rehydration on the lubrication properties of phospholipid polymer-grafted cross-linked polyethylene.
Yarimitsu S; Moro T; Kyomoto M; Watanabe K; Tanaka S; Ishihara K; Murakami T
Proc Inst Mech Eng H; 2015 Jul; 229(7):506-14. PubMed ID: 26036469
[TBL] [Abstract][Full Text] [Related]
15. High lubricious surface of cobalt-chromium-molybdenum alloy prepared by grafting poly(2-methacryloyloxyethyl phosphorylcholine).
Kyomoto M; Iwasaki Y; Moro T; Konno T; Miyaji F; Kawaguchi H; Takatori Y; Nakamura K; Ishihara K
Biomaterials; 2007 Jul; 28(20):3121-30. PubMed ID: 17416412
[TBL] [Abstract][Full Text] [Related]
16. Prevention of bacterial adhesion and biofilm formation on a vitamin E-blended, cross-linked polyethylene surface with a poly(2-methacryloyloxyethyl phosphorylcholine) layer.
Kyomoto M; Shobuike T; Moro T; Yamane S; Takatori Y; Tanaka S; Miyamoto H; Ishihara K
Acta Biomater; 2015 Sep; 24():24-34. PubMed ID: 26050636
[TBL] [Abstract][Full Text] [Related]
17. Developing a thermal grafting process for zwitterionic polymers on cross-linked polyethylene with geometry-independent grafting thickness.
Lim CM; Hur J; Jang H; Seo JH
Acta Biomater; 2019 Feb; 85():180-191. PubMed ID: 30583111
[TBL] [Abstract][Full Text] [Related]
18. Long-term hip simulator testing of the artificial hip joint bearing surface grafted with biocompatible phospholipid polymer.
Moro T; Takatori Y; Kyomoto M; Ishihara K; Hashimoto M; Ito H; Tanaka T; Oshima H; Tanaka S; Kawaguchi H
J Orthop Res; 2014 Mar; 32(3):369-76. PubMed ID: 24249706
[TBL] [Abstract][Full Text] [Related]
19. 2006 Frank Stinchfield Award: grafting of biocompatible polymer for longevity of artificial hip joints.
Moro T; Takatori Y; Ishihara K; Nakamura K; Kawaguchi H
Clin Orthop Relat Res; 2006 Dec; 453():58-63. PubMed ID: 17053564
[TBL] [Abstract][Full Text] [Related]
20. Multidirectional wear and impact-to-wear tests of phospholipid-polymer-grafted and vitamin E-blended crosslinked polyethylene: a pilot study.
Kyomoto M; Moro T; Takatori Y; Tanaka S; Ishihara K
Clin Orthop Relat Res; 2015 Mar; 473(3):942-51. PubMed ID: 25342007
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]