These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

93 related articles for article (PubMed ID: 17598478)

  • 21. [Conversion of load intensity from a bicycle ergometer to a treadmill].
    Bunc V; Heller J; Leso J; Petrzílková Z
    Cas Lek Cesk; 1988 Apr; 127(18):560-2. PubMed ID: 3396038
    [No Abstract]   [Full Text] [Related]  

  • 22. A reproducibility study on musculotendinous stiffness quantification, using a new transportable ankle ergometer device.
    Lambertz D; Paiva MG; Marinho SM; Aragão RS; Barros KM; Manhães-de-Castro R; Khider N; Canon F
    J Biomech; 2008 Nov; 41(15):3270-3. PubMed ID: 18848701
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Heart rate regulation during cycle-ergometer exercise via bio-feedback.
    Argha A; Su SW; Hung Nguyen ; Celler BG
    Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():4639-42. PubMed ID: 26737328
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Validity and reliability of the Ergomopro powermeter.
    Kirkland A; Coleman D; Wiles JD; Hopker J
    Int J Sports Med; 2008 Nov; 29(11):913-6. PubMed ID: 18512176
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A programmable electrically braked ergometer.
    Giezendanner D; Di Prampero PE; Cerretelli P
    J Appl Physiol Respir Environ Exerc Physiol; 1983 Aug; 55(2):578-82. PubMed ID: 6688615
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A novel theoretical framework for the dynamic stability analysis, movement control, and trajectory generation in a multisegment biomechanical model.
    Iqbal K; Roy A
    J Biomech Eng; 2009 Jan; 131(1):011002. PubMed ID: 19045918
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Consistency of within-cycle torque distribution pattern in hand cycling.
    Verellen J; Meyer C; Reynders S; Van Biesen D; Vanlandewijck Y
    J Rehabil Res Dev; 2008; 45(9):1295-302. PubMed ID: 19319754
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Cycle ergometers in rehabilitation medicine: technical characteristics and selection criteria].
    Capodaglio P; Sartorio F; Colombo R; Franchignoni F
    G Ital Med Lav Ergon; 2007; 29(4):942-8. PubMed ID: 18409268
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Enhancing the performance of parallel cascade control using Smith predictor.
    Rao AS; Seethaladevi S; Uma S; Chidambaram M
    ISA Trans; 2009 Apr; 48(2):220-7. PubMed ID: 19054509
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The dynamic natures of implant loading.
    Wang RF; Kang B; Lang LA; Razzoog ME
    J Prosthet Dent; 2009 Jun; 101(6):359-71. PubMed ID: 19463663
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Adaptive fuzzy output-feedback controller design for nonlinear time-delay systems with unknown control direction.
    Hua CC; Wang QG; Guan XP
    IEEE Trans Syst Man Cybern B Cybern; 2009 Apr; 39(2):363-74. PubMed ID: 19095556
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Screening-diagnostics of the myocardium during test-loading on bicycle ergometer].
    Stepanova GP; Skedina MA; Degterenkova NV; Kashenkova LA; Voronkov IuI
    Aviakosm Ekolog Med; 2009; 43(3):68-73. PubMed ID: 19711867
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Winching up heavy loads with a compliant arm: a new local joint controller.
    Schneider A; Cruse H; Schmitz J
    Biol Cybern; 2008 May; 98(5):413-26. PubMed ID: 18414891
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Linear magnetic clutch to automatically control torque output.
    Tsai NC; Yeh CT; Chiu HL
    ISA Trans; 2018 May; 76():224-234. PubMed ID: 29625752
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Strategies for generating prolonged functional standing using intramuscular stimulation or intraspinal microstimulation.
    Lau B; Guevremont L; Mushahwar VK
    IEEE Trans Neural Syst Rehabil Eng; 2007 Jun; 15(2):273-85. PubMed ID: 17601198
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Treadmills and ergometers.
    Sendall MJ; Thrush AJ
    Eur J Vasc Endovasc Surg; 1998 Nov; 16(5):449-50. PubMed ID: 9854562
    [No Abstract]   [Full Text] [Related]  

  • 37. Treadmills and ergometers.
    Hill PD
    Eur J Vasc Endovasc Surg; 1998 Nov; 16(5):449. PubMed ID: 9854561
    [No Abstract]   [Full Text] [Related]  

  • 38. Interaction torque contributes to planar reaching at slow speed.
    Yamasaki H; Tagami Y; Fujisawa H; Hoshi F; Nagasaki H
    Biomed Eng Online; 2008 Oct; 7():27. PubMed ID: 18940016
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A three-pressure-sensor (3PS) system for monitoring ankle supination torque during sport motions.
    Fong DT; Chan YY; Hong Y; Yung PS; Fung KY; Chan KM
    J Biomech; 2008 Aug; 41(11):2562-6. PubMed ID: 18617177
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A closed-loop cross-correlation method for detecting model mismatch in MIMO model-based controllers.
    Webber JR; Gupta YP
    ISA Trans; 2008 Oct; 47(4):395-400. PubMed ID: 18653185
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.