BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 17600613)

  • 1. Re: Renaud Bollens, Dimitri Mikhaski, Baldo P. Espinoza, Alberto Rosenblatt, Anh Dung Hoang, Daniel Abramowicz, Vincent Donckier and Claude Schulman. Laparoscopic live donor right nephrectomy: a new technique to maximize the length of the renal vein using a modified endo GIA stapler? Eur Urol 2007;51:1326-31.
    Deger S; Giessing M
    Eur Urol; 2007 Oct; 52(4):1269-70. PubMed ID: 17600613
    [No Abstract]   [Full Text] [Related]  

  • 2. Laparoscopic live donor right nephrectomy: a new technique to maximize the length of the renal vein using a modified Endo GIA stapler.
    Bollens R; Mikhaski D; Espinoza BP; Rosenblatt A; Hoang AD; Abramowicz D; Donckier V; Schulman CC
    Eur Urol; 2007 May; 51(5):1326-31. PubMed ID: 17197070
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Techniques of vascular control in laparoscopic donor nephrectomy.
    Liu KL; Chiang YJ; Wang HH; Chu SH
    Transplant Proc; 2008 Sep; 40(7):2342-4. PubMed ID: 18790230
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Renal vein extension using gonadal vein: a useful strategy for right kidney living donor harvested using laparoscopy.
    Troncoso P; Guzman S; Domínguez J; Ortiz AM
    Transplant Proc; 2009; 41(1):82-4. PubMed ID: 19249482
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Is reluctance to right-sided laparoscopic living donor nephrectomy justified?
    Burgos J
    Eur Urol; 2007 May; 51(5):1171-2. PubMed ID: 17241739
    [No Abstract]   [Full Text] [Related]  

  • 6. Comparison of techniques of vascular control in laparoscopic donor nephrectomy: The leicester experience.
    Kaushik M; Bagul A; Yates PJ; Elwell R; Nicholson ML
    Transplant Proc; 2006 Dec; 38(10):3406-8. PubMed ID: 17175287
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Initial Experience with the Use of a Robotic Stapler for Robot-Assisted Donor Nephrectomy.
    Perkins SQ; Giffen ZC; Buck BJ; Ortiz J; Sindhwani P; Ekwenna O
    J Endourol; 2018 Nov; 32(11):1054-1057. PubMed ID: 30160167
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Right laparoscopic donor nephrectomy and the use of inverted kidney transplantation: an alternative technique.
    Thomas AJ; Kekre NS
    BJU Int; 2008 Apr; 101(8):1052; author reply 1052-3. PubMed ID: 18353160
    [No Abstract]   [Full Text] [Related]  

  • 9. Use of Hem-o-lok clips effectively lengthens renal vein during laparoscopic live donor nephrectomy.
    Chueh SC; Wang SM; Lai MK
    Transplant Proc; 2004 Nov; 36(9):2623-4. PubMed ID: 15621106
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of right and left laparoscopic live donor nephrectomy.
    Kay MD; Brook N; Kaushik M; Harper SJ; Bagul A; Nicholson ML
    BJU Int; 2006 Oct; 98(4):843-4. PubMed ID: 16978281
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Renal Hilus Ligation With Single Stapler in Laparoscopic Donor Nephrectomy.
    Tokaç M; Eren E; Özçelik Ü; Şahin T; Dinçkan A
    Transplant Proc; 2019 Sep; 51(7):2225-2227. PubMed ID: 31378466
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Right laparoscopic donor nephrectomy and the use of inverted kidney transplantation: an alternative technique.
    Simforoosh N; Aminsharifi A; Tabibi A; Fattahi M; Mahmoodi H; Tavakoli M
    BJU Int; 2007 Dec; 100(6):1347-50. PubMed ID: 17850376
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Control of the renal artery and vein with the nonabsorbable polymer ligating clip in hand-assisted laparoscopic donor nephrectomy.
    Baldwin DD; Desai PJ; Baron PW; Berger KA; Maynes LJ; Robson CH; Ojogho ON; Concepcion W
    Transplantation; 2005 Aug; 80(3):310-3. PubMed ID: 16082324
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Techniques to optimize vascular control during laparoscopic donor nephrectomy.
    Meng MV; Freise CE; Kang SM; Duh QY; Stoller ML
    Urology; 2003 Jan; 61(1):93-7; discussion 97-8. PubMed ID: 12559274
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clipless management of the renal vein during hand-assist laparoscopic donor nephrectomy.
    Rosenblatt GS; Conlin MJ
    BMC Urol; 2006 Sep; 6():23. PubMed ID: 16978416
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Utility of the endovascular stapler for right-sided laparoscopic donor nephrectomy: a 7-year experience at Mayo Clinic.
    Ko EY; Castle EP; Desai PJ; Moss AA; Reddy KS; Mekeel KL; Mulligan DC; Andrews PE
    J Am Coll Surg; 2008 Dec; 207(6):896-903. PubMed ID: 19183537
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A novel bridging hand-assisted LESS donor nephrectomy technique.
    Mahdavi P; Bowman RJ; Tenggardjaja CF; Jellison FC; Ebrahimi KY; Baldwin DD
    Transplantation; 2010 Oct; 90(7):802-4. PubMed ID: 20881581
    [No Abstract]   [Full Text] [Related]  

  • 18. Re: H. Baumert et al. The use of polymer (Hem-o-lok) clips for management of the renal hilum during laparoscopic nephrectomy. Eur Urol 2006;49:816-9 and P.L. Steinberg et al. re: H. Baumert et al. The Use of Polymer (Hem-o-lok) clips for management of the renal hilum during laparascopic nephrectomy. Eur Urol 2006; 49:816-9. Eur Urol 2007;51:572-3.
    Meng MV
    Eur Urol; 2007 Feb; 51(2):574-5; author reply 575-6. PubMed ID: 17055145
    [No Abstract]   [Full Text] [Related]  

  • 19. Hand-assisted laparoscopic live donor nephrectomy (right-sided approach): experience obtained from 31 cases.
    Maciel RF
    Transplant Proc; 2007 Oct; 39(8):2476-7. PubMed ID: 17954151
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The use of polymer (Hem-o-lok) clips for management of the renal hilum during laparoscopic nephrectomy.
    Baumert H; Ballaro A; Arroyo C; Kaisary AV; Mulders PF; Knipscheer BC
    Eur Urol; 2006 May; 49(5):816-9. PubMed ID: 16530930
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.