273 related articles for article (PubMed ID: 17601546)
1. Valve-in-a-valve concept for transcatheter minimally invasive repeat xenograft implantation.
Walther T; Falk V; Dewey T; Kempfert J; Emrich F; Pfannmüller B; Bröske P; Borger MA; Schuler G; Mack M; Mohr FW
J Am Coll Cardiol; 2007 Jul; 50(1):56-60. PubMed ID: 17601546
[TBL] [Abstract][Full Text] [Related]
2. Transapical minimally invasive aortic valve implantation; the initial 50 patients.
Walther T; Falk V; Kempfert J; Borger MA; Fassl J; Chu MW; Schuler G; Mohr FW
Eur J Cardiothorac Surg; 2008 Jun; 33(6):983-8. PubMed ID: 18294859
[TBL] [Abstract][Full Text] [Related]
3. Transapical approach for sutureless stent-fixed aortic valve implantation: experimental results.
Walther T; Dewey T; Wimmer-Greinecker G; Doss M; Hambrecht R; Schuler G; Mohr FW; Mack M
Eur J Cardiothorac Surg; 2006 May; 29(5):703-8. PubMed ID: 16600616
[TBL] [Abstract][Full Text] [Related]
4. Minimally invasive off-pump valve-in-a-valve implantation: the atrial transcatheter approach for re-operative mitral valve replacement.
Kempfert J; Blumenstein JM; Borger MA; Linke A; Lehmann S; Pritzwald-Stegmann P; Chu MW; Schuler G; Falk V; Mohr FW; Walther T
Eur Heart J; 2008 Oct; 29(19):2382-7. PubMed ID: 18567669
[TBL] [Abstract][Full Text] [Related]
5. Transapical implantation of a novel self-expanding sutureless aortic valve prosthesis.
Stalder M; Suri RM; Kraehenbuehl ES; Hellige G; Wenaweser P; Zobrist C; Schaff HV; Carrel TP
J Heart Valve Dis; 2010 Mar; 19(2):182-7; discussion 188. PubMed ID: 20369501
[TBL] [Abstract][Full Text] [Related]
6. Transapical minimally invasive aortic valve implantation: multicenter experience.
Walther T; Simon P; Dewey T; Wimmer-Greinecker G; Falk V; Kasimir MT; Doss M; Borger MA; Schuler G; Glogar D; Fehske W; Wolner E; Mohr FW; Mack M
Circulation; 2007 Sep; 116(11 Suppl):I240-5. PubMed ID: 17846311
[TBL] [Abstract][Full Text] [Related]
7. Transapical aortic valve implantation: an animal feasibility study.
Dewey TM; Walther T; Doss M; Brown D; Ryan WH; Svensson L; Mihaljevic T; Hambrecht R; Schuler G; Wimmer-Greinecker G; Mohr FW; Mack MJ
Ann Thorac Surg; 2006 Jul; 82(1):110-6. PubMed ID: 16798200
[TBL] [Abstract][Full Text] [Related]
8. Transapical off-pump valve-in-valve implantation in patients with degenerated aortic xenografts.
Kempfert J; Van Linden A; Linke A; Borger MA; Rastan A; Mukherjee C; Ender J; Schuler G; Mohr FW; Walther T
Ann Thorac Surg; 2010 Jun; 89(6):1934-41. PubMed ID: 20494052
[TBL] [Abstract][Full Text] [Related]
9. Transapical implantation of a self-expanding aortic valve bioprosthesis--animal feasibility study.
Kappetein AP; Piazza N; Laborde JC; de Jaegere PP; Serruys PW
Eur J Cardiothorac Surg; 2009 Nov; 36(5):813-7. PubMed ID: 19682918
[TBL] [Abstract][Full Text] [Related]
10. Transapical aortic valve implantation in patients requiring redo surgery.
Walther T; Falk V; Borger MA; Kempfert J; Ender J; Linke A; Schuler G; Mohr FW
Eur J Cardiothorac Surg; 2009 Aug; 36(2):231-4; discussion 234-5. PubMed ID: 19324566
[TBL] [Abstract][Full Text] [Related]
11. Transapical transcatheter aortic valve implantation in humans: initial clinical experience.
Lichtenstein SV; Cheung A; Ye J; Thompson CR; Carere RG; Pasupati S; Webb JG
Circulation; 2006 Aug; 114(6):591-6. PubMed ID: 16880325
[TBL] [Abstract][Full Text] [Related]
12. Transapical aortic 'valve-in-valve' procedure for degenerated stented bioprosthesis.
Ferrari E
Eur J Cardiothorac Surg; 2012 Mar; 41(3):485-90. PubMed ID: 22011780
[TBL] [Abstract][Full Text] [Related]
13. Transcatheter Aortic and Mitral Valve-in-Valve Implantation for Failed Surgical Bioprosthetic Valves: An 8-Year Single-Center Experience.
Ye J; Cheung A; Yamashita M; Wood D; Peng D; Gao M; Thompson CR; Munt B; Moss RR; Blanke P; Leipsic J; Dvir D; Webb JG
JACC Cardiovasc Interv; 2015 Nov; 8(13):1735-44. PubMed ID: 26476608
[TBL] [Abstract][Full Text] [Related]
14. Results of percutaneous and transapical transcatheter aortic valve implantation performed by a surgical team.
Bleiziffer S; Ruge H; Mazzitelli D; Schreiber C; Hutter A; Laborde JC; Bauernschmitt R; Lange R
Eur J Cardiothorac Surg; 2009 Apr; 35(4):615-20; discussion 620-1. PubMed ID: 19233669
[TBL] [Abstract][Full Text] [Related]
15. Is transapical aortic valve implantation really less invasive than minimally invasive aortic valve replacement?
Zierer A; Wimmer-Greinecker G; Martens S; Moritz A; Doss M
J Thorac Cardiovasc Surg; 2009 Nov; 138(5):1067-72. PubMed ID: 19740493
[TBL] [Abstract][Full Text] [Related]
16. Transcatheter aortic valve implantation: anesthetic considerations.
Billings FT; Kodali SK; Shanewise JS
Anesth Analg; 2009 May; 108(5):1453-62. PubMed ID: 19372319
[TBL] [Abstract][Full Text] [Related]
17. Transapical transcatheter mitral valve-in-valve implantation in a human.
Cheung A; Webb JG; Wong DR; Ye J; Masson JB; Carere RG; Lichtenstein SV
Ann Thorac Surg; 2009 Mar; 87(3):e18-20. PubMed ID: 19231366
[TBL] [Abstract][Full Text] [Related]
18. New insights in minimally invasive valve replacement: description of a cooperative approach for the off-pump replacement of mitral valves.
Boudjemline Y; Pineau E; Borenstein N; Behr L; Bonhoeffer P
Eur Heart J; 2005 Oct; 26(19):2013-7. PubMed ID: 15872031
[TBL] [Abstract][Full Text] [Related]
19. First percutaneous transcatheter aortic valve-in-valve implant with three year follow-up.
Ruiz CE; Laborde JC; Condado JF; Chiam PT; Condado JA
Catheter Cardiovasc Interv; 2008 Aug; 72(2):143-8. PubMed ID: 18655115
[TBL] [Abstract][Full Text] [Related]
20. Minimally invasive transapical beating heart aortic valve implantation--proof of concept.
Walther T; Falk V; Borger MA; Dewey T; Wimmer-Greinecker G; Schuler G; Mack M; Mohr FW
Eur J Cardiothorac Surg; 2007 Jan; 31(1):9-15. PubMed ID: 17097302
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]