These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 1760171)

  • 1. Management of the challenging airway with the Bullard laryngoscope.
    Gorback MS
    J Clin Anesth; 1991; 3(6):473-7. PubMed ID: 1760171
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of Bullard and Airtraq laryngoscopes with conventional laryngoscopy in a manikin study of simulated difficult intubation.
    Legrand MA; Steinmann D; Priebe HJ; Mols G
    Eur J Anaesthesiol; 2012 Jul; 29(7):343-50. PubMed ID: 22569030
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prospective model-based comparison of different laryngoscopes for difficult intubation in infants.
    Kalbhenn J; Boelke AK; Steinmann D
    Paediatr Anaesth; 2012 Aug; 22(8):776-80. PubMed ID: 22646973
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Bullard laryngoscope. Reports of two cases of difficult intubation.
    Midttun M; Laerkholm Hansen C; Jensen K; Pedersen T
    Acta Anaesthesiol Scand; 1994 Apr; 38(3):300-2. PubMed ID: 8023673
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Intratracheal intubation using a fiberoptic laryngoscope].
    Riou B; Langeron O; Fabas E; Viars P
    Ann Fr Anesth Reanim; 1991; 10(3):308-10. PubMed ID: 1854060
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [A new method for endotracheal intubation with the Bullard laryngoscope].
    Miyazawa N; Shigematsu T; Kaneko S; Tabuchi H; Yorozu T; Saito N; Tashiro M
    Masui; 1992 Feb; 41(2):263-9. PubMed ID: 1552667
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of the Bullard and Macintosh laryngoscopes for endotracheal intubation of patients with a potential cervical spine injury.
    Watts AD; Gelb AW; Bach DB; Pelz DM
    Anesthesiology; 1997 Dec; 87(6):1335-42. PubMed ID: 9416718
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A simple fibreoptic assisted laryngoscope for paediatric difficult intubation: a manikin study.
    Komiya K; Inagawa G; Nakamura K; Kikuchi T; Fujimoto J; Sugawara Y; Goto T
    Anaesthesia; 2009 Apr; 64(4):425-9. PubMed ID: 19317709
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Use of Bullard laryngoscope in intubation of the trachea].
    Lubnin AIu; Shmigel'skiĭ AV; Kolokol'nikov AE
    Anesteziol Reanimatol; 1998; (3):67-71. PubMed ID: 9693440
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Superior glottic views with the GlideScope® and Airtraq® laryngoscopes compared with an anterior commissure laryngoscope.
    Khan SM; Cooper RM
    Can J Anaesth; 2011 Feb; 58(2):224-5. PubMed ID: 21076950
    [No Abstract]   [Full Text] [Related]  

  • 11. Facilitation of difficult tracheal intubation by the fiberoptic Bullard laryngoscope.
    Baraka A; Muallem M; Sibai AN
    Middle East J Anaesthesiol; 1991 Feb; 11(1):73-7. PubMed ID: 2067507
    [No Abstract]   [Full Text] [Related]  

  • 12. [A comparison of bullard laryngoscope and intubating laryngeal mask using fiberoptic guidance for tracheal intubation].
    Onizuka S; Kawano T; Takasaki M
    Masui; 2000 Jul; 49(7):736-9. PubMed ID: 10933023
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of the Bullard laryngoscope in the adult patient with epiglottitis: a case report.
    Spain K
    AANA J; 2002 Apr; 70(2):127-9. PubMed ID: 11969063
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Utility of Bullard intubating laryngoscope with a special stylet in two cases of difficult tracheal intubation].
    Yamakage M; Yamazaki Y; Iwasaki H; Namiki A
    Masui; 1991 Sep; 40(9):1404-6. PubMed ID: 1942516
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Nasotracheal intubation using Bullard laryngoscope.
    Shigematsu T; Miyazawa N; Yorozu T
    Can J Anaesth; 1991 Sep; 38(6):798. PubMed ID: 1914069
    [No Abstract]   [Full Text] [Related]  

  • 16. Bullard laryngoscopy by naïve operators in the cervical spine immobilized patient.
    Wackett A; Anderson K; Thode H
    J Emerg Med; 2005 Oct; 29(3):253-7. PubMed ID: 16183442
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Difficult airway management: comparison of the Bullard laryngoscope with the video-optical intubation stylet.
    Weiss M; Schwarz U; Gerber AC
    Can J Anaesth; 2000 Mar; 47(3):280-4. PubMed ID: 10730742
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Awake intubation of the adult trachea using the Bullard laryngoscope.
    Cohn AI; McGraw SR; King WH
    Can J Anaesth; 1995 Mar; 42(3):246-8. PubMed ID: 7743580
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Bullard laryngoscope and size of the endotracheal tube.
    Katsnelson T; Farcon E; Cosio M; Schwalbe SS
    Anesthesiology; 1994 Jul; 81(1):261-2. PubMed ID: 8042797
    [No Abstract]   [Full Text] [Related]  

  • 20. A comparison of the GlideScope with the Macintosh laryngoscope for nasotracheal intubation in patients with ankylosing spondylitis.
    Lili X; Zhiyong H; Jianjun S
    J Neurosurg Anesthesiol; 2014 Jan; 26(1):27-31. PubMed ID: 23764717
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.