These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
140 related articles for article (PubMed ID: 17603387)
1. Navigation reduces the learning curve in resurfacing total hip arthroplasty. Cobb JP; Kannan V; Brust K; Thevendran G Clin Orthop Relat Res; 2007 Oct; 463():90-7. PubMed ID: 17603387 [TBL] [Abstract][Full Text] [Related]
2. Computer-assisted navigation in hip resurfacing arthroplasty - a single-surgeon experience. Shields JS; Seyler TM; Maguire C; Jinnah RH Bull NYU Hosp Jt Dis; 2009; 67(2):164-7. PubMed ID: 19583547 [TBL] [Abstract][Full Text] [Related]
3. The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham Hip Resurfacing: a cadaver study. Davis ET; Gallie P; Macgroarty K; Waddell JP; Schemitsch E J Bone Joint Surg Br; 2007 Apr; 89(4):557-60. PubMed ID: 17463131 [TBL] [Abstract][Full Text] [Related]
4. [Functionality and accuracy of a fluoroscopic navigation system in the placement of the femoral component for hip resurfacing - a cadaver study]. Gravius S; Belei P; de la Fuente M; Müller-Rath R; Radermacher K; Wirtz D; Mumme T Z Orthop Unfall; 2008; 146(3):357-63. PubMed ID: 18561082 [TBL] [Abstract][Full Text] [Related]
5. Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study. Lin F; Lim D; Wixson RL; Milos S; Hendrix RW; Makhsous M Clin Biomech (Bristol); 2008 Oct; 23(8):1004-11. PubMed ID: 18541352 [TBL] [Abstract][Full Text] [Related]
7. [Fluoroscopic navigation versus conventional manual positioning of the femoral component for hip resurfacing: first experimental trial]. Gravius S; Belei P; de la Fuente M; Müller-Rath R; Radermacher K; Christian Wirtz D; Mumme T Biomed Tech (Berl); 2008 Aug; 53(4):204-12. PubMed ID: 18643714 [TBL] [Abstract][Full Text] [Related]
8. [Accuracy improvement of acetabular component placement using non-image based surgical navigation system]. Yu Z; Wang L; Gui J Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2007 Oct; 21(10):1057-61. PubMed ID: 17990769 [TBL] [Abstract][Full Text] [Related]
9. A comparison of conventional guidewire alignment jigs with imageless computer navigation in hip resurfacing arthroplasty. Olsen M; Chiu M; Gamble P; Boyle RA; Tumia N; Schemitsch EH J Bone Joint Surg Am; 2010 Aug; 92(9):1834-41. PubMed ID: 20686057 [TBL] [Abstract][Full Text] [Related]
10. The influence of computer navigation on trainee learning in hip resurfacing arthroplasty. Saithna A; Dekker AP Comput Aided Surg; 2009; 14(4-6):117-22. PubMed ID: 20121591 [TBL] [Abstract][Full Text] [Related]
11. Component alignment in hip resurfacing using computer navigation. Bailey C; Gul R; Falworth M; Zadow S; Oakeshott R Clin Orthop Relat Res; 2009 Apr; 467(4):917-22. PubMed ID: 18972176 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of component positioning in primary total hip arthroplasty using an imageless navigation device compared with traditional methods. Najarian BC; Kilgore JE; Markel DC J Arthroplasty; 2009 Jan; 24(1):15-21. PubMed ID: 18534411 [TBL] [Abstract][Full Text] [Related]
13. Does computer-assisted surgery improve accuracy and decrease the learning curve in hip resurfacing? A radiographic analysis. Seyler TM; Lai LP; Sprinkle DI; Ward WG; Jinnah RH J Bone Joint Surg Am; 2008 Aug; 90 Suppl 3():71-80. PubMed ID: 18676940 [TBL] [Abstract][Full Text] [Related]
14. [Rotational alignment of femoral component with computed-assisted surgery (CAS) during total knee arthroplasty]. Michaut M; Beaufils P; Galaud B; Abadie P; Boisrenoult P; Fallet L Rev Chir Orthop Reparatrice Appar Mot; 2008 Oct; 94(6):580-4. PubMed ID: 18929753 [TBL] [Abstract][Full Text] [Related]
15. Imageless computer navigation without pre-operative templating may lead to malpreparation of the femoral head in hip resurfacing. Olsen M; Davis ET; Chiu M; Gamble P; Tumia N; Boyle RA; Schemitsch EH J Bone Joint Surg Br; 2009 Oct; 91(10):1281-6. PubMed ID: 19794160 [TBL] [Abstract][Full Text] [Related]
16. Total hip arthroplasty in osteopetrosis using computer-assisted fluoroscopic navigation. Egawa H; Nakano S; Hamada D; Sato R; Yasui N J Arthroplasty; 2005 Dec; 20(8):1074-7. PubMed ID: 16376266 [TBL] [Abstract][Full Text] [Related]
17. Computer-assisted vs conventional mechanical jig technique in hip resurfacing arthroplasty. Resubal JR; Morgan DA J Arthroplasty; 2009 Apr; 24(3):341-50. PubMed ID: 18534413 [TBL] [Abstract][Full Text] [Related]
18. Accuracy and repeatability of cementless total hip replacement surgery in patients with deformed anatomies. Lattanzi R; Grazi E; Testi D; Viceconti M; Cappello A; Toni A Med Inform Internet Med; 2003 Mar; 28(1):59-71. PubMed ID: 12851057 [TBL] [Abstract][Full Text] [Related]
19. Learning how to resurface cam-type femoral heads with acceptable accuracy and precision: the role of computed tomography-based navigation. Cobb JP; Kannan V; Dandachli W; Iranpour F; Brust KU; Hart AJ J Bone Joint Surg Am; 2008 Aug; 90 Suppl 3():57-64. PubMed ID: 18676938 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of a patient specific femoral alignment guide for hip resurfacing. Olsen M; Naudie DD; Edwards MR; Sellan ME; McCalden RW; Schemitsch EH J Arthroplasty; 2014 Mar; 29(3):590-5. PubMed ID: 24034907 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]