124 related articles for article (PubMed ID: 17604312)
1. Second harmonic generation in neurons: electro-optic mechanism of membrane potential sensitivity.
Jiang J; Eisenthal KB; Yuste R
Biophys J; 2007 Sep; 93(5):L26-8. PubMed ID: 17604312
[TBL] [Abstract][Full Text] [Related]
2. Imaging membrane potential in dendritic spines.
Nuriya M; Jiang J; Nemet B; Eisenthal KB; Yuste R
Proc Natl Acad Sci U S A; 2006 Jan; 103(3):786-90. PubMed ID: 16407122
[TBL] [Abstract][Full Text] [Related]
3. Electro-optic response of second-harmonic generation membrane potential sensors.
Moreaux L; Pons T; Dambrin V; Blanchard-Desce M; Mertz J
Opt Lett; 2003 Apr; 28(8):625-7. PubMed ID: 12703921
[TBL] [Abstract][Full Text] [Related]
4. Optical recording of fast neuronal membrane potential transients in acute mammalian brain slices by second-harmonic generation microscopy.
Dombeck DA; Sacconi L; Blanchard-Desce M; Webb WW
J Neurophysiol; 2005 Nov; 94(5):3628-36. PubMed ID: 16093337
[TBL] [Abstract][Full Text] [Related]
5. High-resolution nonlinear optical imaging of live cells by second harmonic generation.
Campagnola PJ; Wei MD; Lewis A; Loew LM
Biophys J; 1999 Dec; 77(6):3341-9. PubMed ID: 10585956
[TBL] [Abstract][Full Text] [Related]
6. Microscopic second harmonic generation (SHG) from tilt-placed collagen fibrils.
Chang Y; Wei H; Jin Y; Liu H; Deng X
Gen Physiol Biophys; 2011 Jun; 30(2):175-85. PubMed ID: 21613673
[TBL] [Abstract][Full Text] [Related]
7. Second-harmonic generation sensitivity to transmembrane potential in normal and tumor cells.
Sacconi L; D'Amico M; Vanzi F; Biagiotti T; Antolini R; Olivotto M; Pavone FS
J Biomed Opt; 2005; 10(2):024014. PubMed ID: 15910088
[TBL] [Abstract][Full Text] [Related]
8. Second Harmonic Imaging of Membrane Potential.
Loew LM; Lewis A
Adv Exp Med Biol; 2015; 859():473-92. PubMed ID: 26238065
[TBL] [Abstract][Full Text] [Related]
9. High-speed, random-access fluorescence microscopy: II. Fast quantitative measurements with voltage-sensitive dyes.
Bullen A; Saggau P
Biophys J; 1999 Apr; 76(4):2272-87. PubMed ID: 10096922
[TBL] [Abstract][Full Text] [Related]
10. Multimodal two-photon imaging using a second harmonic generation-specific dye.
Nuriya M; Fukushima S; Momotake A; Shinotsuka T; Yasui M; Arai T
Nat Commun; 2016 May; 7():11557. PubMed ID: 27156702
[TBL] [Abstract][Full Text] [Related]
11. Dyes for biological second harmonic generation imaging.
Reeve JE; Anderson HL; Clays K
Phys Chem Chem Phys; 2010 Nov; 12(41):13484-98. PubMed ID: 20820473
[TBL] [Abstract][Full Text] [Related]
12. Second-harmonic generation voltage imaging at subcellular resolution in rat hippocampal slices.
Rama S; Vetrivel L; Semyanov A
J Biophotonics; 2010 Dec; 3(12):784-90. PubMed ID: 20815024
[TBL] [Abstract][Full Text] [Related]
13. Monitoring membrane potential with second-harmonic generation.
Wilson SA; Millard A; Lewis A; Loew LM
Cold Spring Harb Protoc; 2014 Jun; 2014(6):643-54. PubMed ID: 24890213
[TBL] [Abstract][Full Text] [Related]
14. Wavelength- and time-dependence of potentiometric non-linear optical signals from styryl dyes.
Millard AC; Jin L; Wuskell JP; Boudreau DM; Lewis A; Loew LM
J Membr Biol; 2005 Nov; 208(2):103-11. PubMed ID: 16645740
[TBL] [Abstract][Full Text] [Related]
15. Second harmonic imaging of membrane potential of neurons with retinal.
Nemet BA; Nikolenko V; Yuste R
J Biomed Opt; 2004; 9(5):873-81. PubMed ID: 15447008
[TBL] [Abstract][Full Text] [Related]
16. Polarization-resolved Second Harmonic microscopy in anisotropic thick tissues.
Gusachenko I; Latour G; Schanne-Klein MC
Opt Express; 2010 Aug; 18(18):19339-52. PubMed ID: 20940829
[TBL] [Abstract][Full Text] [Related]
17. Action-potential-encoded second-harmonic generation as an ultrafast local probe for nonintrusive membrane diagnostics.
Shneider MN; Voronin AA; Zheltikov AM
Phys Rev E Stat Nonlin Soft Matter Phys; 2010 Mar; 81(3 Pt 1):031926. PubMed ID: 20365789
[TBL] [Abstract][Full Text] [Related]
18. Probing membrane potential with nonlinear optics.
Bouevitch O; Lewis A; Pinevsky I; Wuskell JP; Loew LM
Biophys J; 1993 Aug; 65(2):672-9. PubMed ID: 8218895
[TBL] [Abstract][Full Text] [Related]
19. Engineering a genetically-encoded SHG chromophore by electrostatic targeting to the membrane.
Jinno Y; Shoda K; Rial-Verde E; Yuste R; Miyawaki A; Tsutsui H
Front Mol Neurosci; 2014; 7():93. PubMed ID: 25505870
[TBL] [Abstract][Full Text] [Related]
20. Optical clearing for improved contrast in second harmonic generation imaging of skeletal muscle.
Plotnikov S; Juneja V; Isaacson AB; Mohler WA; Campagnola PJ
Biophys J; 2006 Jan; 90(1):328-39. PubMed ID: 16214853
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]