287 related articles for article (PubMed ID: 17605405)
1. Roche Elecsys Prolactin II assay: reactivity with macroprolactin compared with eight commercial assays for prolactin and determination of monomeric prolactin by precipitation with polyethylene glycol.
Fahie-Wilson M; Bieglmayer C; Kratzsch J; Nusbaumer C; Roth HJ; Zaninotto M; Plebani M; Hubbuch A; Schneider E
Clin Lab; 2007; 53(5-6):301-7. PubMed ID: 17605405
[TBL] [Abstract][Full Text] [Related]
2. Roche Elecsys Prolactin II assay: reactivity with macroprolactin compared with eight commercial assays for prolactin and determination of monomeric prolactin by precipitation with polyethylene glycol.
Fahie-Wilson M; Bieglmayer C; Kratzsch J; Nusbaumer C; Roth HJ; Zaninotto M; Plebani M; Hubbuch A; Schneider E
Clin Lab; 2007; 53(7-8):485-92. PubMed ID: 17821956
[TBL] [Abstract][Full Text] [Related]
3. Macroprolactin on the Advia Centaur: experience with 409 patients over a three-year period.
Jassam NF; Paterson A; Lippiatt C; Barth JH
Ann Clin Biochem; 2009 Nov; 46(Pt 6):501-4. PubMed ID: 19850593
[TBL] [Abstract][Full Text] [Related]
4. Free prolactin determinations in hyperprolactinemic men with suspicion of macroprolactinemia.
Sapin R; Gasser F; Grucker D
Clin Chim Acta; 2002 Feb; 316(1-2):33-41. PubMed ID: 11750272
[TBL] [Abstract][Full Text] [Related]
5. Cross-reactivities of macroprolactin and big-prolactin in three commercial immunoassays for prolactin: a chromatographic analysis.
Ellis MJ; Reed MR; Livesey JH
Clin Biochem; 2007 Nov; 40(16-17):1285-90. PubMed ID: 17825807
[TBL] [Abstract][Full Text] [Related]
6. False-positive polyethylene glycol precipitation tests for macroprolactin due to increased serum globulins.
Ram S; Harris B; Fernando JJ; Gama R; Fahie-Wilson M
Ann Clin Biochem; 2008 May; 45(Pt 3):256-9. PubMed ID: 18482912
[TBL] [Abstract][Full Text] [Related]
7. Macroprolactin, big-prolactin and potential effects on the misdiagnosis of hyperprolactinemia using the Beckman Coulter Access Prolactin assay.
Ellis MJ; Livesey JH; Soule SG
Clin Biochem; 2006 Oct; 39(10):1028-34. PubMed ID: 16919253
[TBL] [Abstract][Full Text] [Related]
8. Reactivity of macroprolactin in common automated immunoassays.
Schneider W; Marcovitz S; Al-Shammari S; Yago S; Chevalier S
Clin Biochem; 2001 Sep; 34(6):469-73. PubMed ID: 11676976
[TBL] [Abstract][Full Text] [Related]
9. Serum prolactin revisited: parametric reference intervals and cross platform evaluation of polyethylene glycol precipitation-based methods for discrimination between hyperprolactinemia and macroprolactinemia.
Overgaard M; Pedersen SM
Clin Chem Lab Med; 2017 Oct; 55(11):1744-1753. PubMed ID: 28236625
[TBL] [Abstract][Full Text] [Related]
10. Macroprolactinemia: predictability on clinical basis and detection by PEG precipitation with two different immunometric methods.
Amadori P; Dilberis C; Marcolla A; Pinamonti M; Menapace P; Dal Bosco F
J Endocrinol Invest; 2003 Feb; 26(2):148-56. PubMed ID: 12739743
[TBL] [Abstract][Full Text] [Related]
11. Macroprolactin; high molecular mass forms of circulating prolactin.
Fahie-Wilson MN; John R; Ellis AR
Ann Clin Biochem; 2005 May; 42(Pt 3):175-92. PubMed ID: 15949152
[TBL] [Abstract][Full Text] [Related]
12. Serum total prolactin and monomeric prolactin reference intervals determined by precipitation with polyethylene glycol: evaluation and validation on common immunoassay platforms.
Beltran L; Fahie-Wilson MN; McKenna TJ; Kavanagh L; Smith TP
Clin Chem; 2008 Oct; 54(10):1673-81. PubMed ID: 18719199
[TBL] [Abstract][Full Text] [Related]
13. Rapid detection of macroprolactin in the form of prolactin-immunoglobulin G complexes by immunoprecipitation with anti-human IgG-agarose.
Schiettecatte J; De Schepper J; Velkeniers B; Smitz J; Van Steirteghem A
Clin Chem Lab Med; 2001 Dec; 39(12):1244-8. PubMed ID: 11798085
[TBL] [Abstract][Full Text] [Related]
14. Hyperprolactinaemia does not always mean 'hyperprolactinaemia'!
Gezer A; Atasü T; Hekim C; Stenman UH; Hekim N
Eur J Obstet Gynecol Reprod Biol; 2005 Feb; 118(2):206-8. PubMed ID: 15653204
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of hyperprolactinaemia with the use of the intervals for prolactin after macroforms separation.
Beda-Maluga K; Pisarek H; Komorowski J; Swietoslawski J; Fuss-Chmielewska J; Winczyk K
J Physiol Pharmacol; 2014 Jun; 65(3):359-64. PubMed ID: 24930507
[TBL] [Abstract][Full Text] [Related]
16. Importance of screening for macroprolactin in all hyperprolactinaemic sera.
Jamaluddin FA; Sthaneshwar P; Hussein Z; Othman N; Chan SP
Malays J Pathol; 2013 Jun; 35(1):59-63. PubMed ID: 23817395
[TBL] [Abstract][Full Text] [Related]
17. Macroprolactinaemia: a biological diagnostic strategy from the study of 222 patients.
Parlant-Pinet L; Harthé C; Roucher F; Morel Y; Borson-Chazot F; Raverot G; Raverot V
Eur J Endocrinol; 2015 Jun; 172(6):687-95. PubMed ID: 25755230
[TBL] [Abstract][Full Text] [Related]
18. [Macroprolactin detection: a new approach].
Sapin R; Gasser F; Fischbach E; Grucker D
Ann Biol Clin (Paris); 2000; 58(6):729-34. PubMed ID: 11098170
[TBL] [Abstract][Full Text] [Related]
19. Gross variability in the detection of prolactin in sera containing big big prolactin (macroprolactin) by commercial immunoassays.
Smith TP; Suliman AM; Fahie-Wilson MN; McKenna TJ
J Clin Endocrinol Metab; 2002 Dec; 87(12):5410-5. PubMed ID: 12466327
[TBL] [Abstract][Full Text] [Related]
20. Prevalence of macroprolactin detected by Elecsys 2010.
Sánchez-Eixerés MR; Mauri M; Alfayate R; Graells ML; Miralles C; López A; Picó A
Horm Res; 2001; 56(3-4):87-92. PubMed ID: 11847468
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]