These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 17614604)

  • 1. Quantitative extraction of spectral line intensities and widths from x-ray spectra recorded with gated microchannel plate detectors.
    Dunham G; Bailey JE; Rochau GA; Lake PW; Nielsen-Weber LB
    Rev Sci Instrum; 2007 Jun; 78(6):063106. PubMed ID: 17614604
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Data acquisition system for an advanced x-ray imaging crystal spectrometer using a segmented position-sensitive detector.
    Nam UW; Lee SG; Bak JG; Moon MK; Cheon JK; Lee CH
    Rev Sci Instrum; 2007 Oct; 78(10):103504. PubMed ID: 17979416
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High-resolution spectroscopy on an X-ray absorption beamline.
    Hazemann JL; Proux O; Nassif V; Palancher H; Lahera E; Da Silva C; Braillard A; Testemale D; Diot MA; Alliot I; Del Net W; Manceau A; Gélébart F; Morand M; Dermigny Q; Shukla A
    J Synchrotron Radiat; 2009 Mar; 16(Pt 2):283-92. PubMed ID: 19240341
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High-energy resolution X-ray, gamma and electron spectroscopy with cryogenic detectors.
    Loidl M; Leblanc E; Bouchard J; Branger T; Coron N; Leblanc J; de Marcillac P; Rotzinger H; Daniyarov T; Linck M; Fleischmann A; Enss C
    Appl Radiat Isot; 2004; 60(2-4):363-8. PubMed ID: 14987669
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A fast energy-dispersive multi-element detector for X-ray absorption spectroscopy.
    Welter E; Hansen K; Reckleben C; Diehl I
    J Synchrotron Radiat; 2009 Mar; 16(Pt 2):293-8. PubMed ID: 19240342
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improving the performance of high-resolution X-ray spectrometers with position-sensitive pixel detectors.
    Huotari S; Vankó G; Albergamo F; Ponchut C; Graafsma H; Henriquet C; Verbeni R; Monaco G
    J Synchrotron Radiat; 2005 Jul; 12(Pt 4):467-72. PubMed ID: 15968123
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development of advanced x-ray imaging crystal spectrometer utilizing a large area segmented proportional counter for KSTAR.
    Lee SG; Bak JG; Nam UW; Moon MK; Cheon JK
    Rev Sci Instrum; 2007 Jun; 78(6):063504. PubMed ID: 17614609
    [TBL] [Abstract][Full Text] [Related]  

  • 8. System for in situ studies of atmospheric corrosion of metal films using soft x-ray spectroscopy and quartz crystal microbalance.
    Forsberg J; Duda LC; Olsson A; Schmitt T; Andersson J; Nordgren J; Hedberg J; Leygraf C; Aastrup T; Wallinder D; Guo JH
    Rev Sci Instrum; 2007 Aug; 78(8):083110. PubMed ID: 17764316
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Angle-resolved photoemission spectroscopy with a femtosecond high harmonic light source using a two-dimensional imaging electron analyzer.
    Mathias S; Miaja-Avila L; Murnane MM; Kapteyn H; Aeschlimann M; Bauer M
    Rev Sci Instrum; 2007 Aug; 78(8):083105. PubMed ID: 17764311
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design and performance of a curved-crystal x-ray emission spectrometer.
    Hudson AC; Stolte WC; Lindle DW; Guillemin R
    Rev Sci Instrum; 2007 May; 78(5):053101. PubMed ID: 17552806
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Picosecond time-resolved laser pump/X-ray probe experiments using a gated single-photon-counting area detector.
    Ejdrup T; Lemke HT; Haldrup K; Nielsen TN; Arms DA; Walko DA; Miceli A; Landahl EC; Dufresne EM; Nielsen MM
    J Synchrotron Radiat; 2009 May; 16(Pt 3):387-90. PubMed ID: 19395803
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development of a high-efficiency high-resolution particle-induced x-ray emission system for chemical state analysis of environmental samples.
    Hasegawa J; Tada T; Oguri Y; Hayashi M; Toriyama T; Kawabata T; Masai K
    Rev Sci Instrum; 2007 Jul; 78(7):073105. PubMed ID: 17672753
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The materials science X-ray beamline BL8 at the DELTA storage ring.
    Lützenkirchen-Hecht D; Wagner R; Haake U; Watenphul A; Frahm R
    J Synchrotron Radiat; 2009 Mar; 16(Pt 2):264-72. PubMed ID: 19240339
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Spectrometer for lanthanides' K x-ray fluorescence.
    Sakurai K; Mizusawa M; Terada Y
    Rev Sci Instrum; 2007 Jun; 78(6):066108. PubMed ID: 17614652
    [TBL] [Abstract][Full Text] [Related]  

  • 15. OZSPEC-2: an improved broadband high-resolution elliptical crystal x-ray spectrometer for high-energy density physics experiments (invited).
    Heeter RF; Anderson SG; Booth R; Brown GV; Emig J; Fulkerson S; McCarville T; Norman D; Schneider MB; Young BK
    Rev Sci Instrum; 2008 Oct; 79(10):10E303. PubMed ID: 19044465
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A wide-aperture dynamically focusing sagittal monochromator for X-ray spectroscopy and diffraction.
    Bilsborrow RL; Atkinson PA; Bliss N; Dent AJ; Dobson BR; Stephenson PC
    J Synchrotron Radiat; 2006 Jan; 13(Pt 1):54-8. PubMed ID: 16371708
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Novel x-ray multispectral imaging of ultraintense laser plasmas by a single-photon charge coupled device based pinhole camera.
    Labate L; Giulietti A; Giulietti D; Köster P; Levato T; Gizzi LA; Zamponi F; Lübcke A; Kämpfer T; Uschmann I; Förster E
    Rev Sci Instrum; 2007 Oct; 78(10):103506. PubMed ID: 17979418
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A maximum-likelihood algorithm for reduction of Langmuir probe data.
    Martin AK; Koelfgen SJ
    Rev Sci Instrum; 2007 Oct; 78(10):103508. PubMed ID: 17979420
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fluorescence rejection in resonance Raman spectroscopy using a picosecond-gated intensified charge-coupled device camera.
    Efremov EV; Buijs JB; Gooijer C; Ariese F
    Appl Spectrosc; 2007 Jun; 61(6):571-8. PubMed ID: 17650366
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optimization of measurement conditions of an energy dispersive X-ray fluorescence spectrometer with high-energy polarized beam excitation for analysis of aerosol filters.
    Spolnik Z; Belikov K; Van Meel K; Adriaenssens E; De Roeck F; Van Grieken R
    Appl Spectrosc; 2005 Dec; 59(12):1465-9. PubMed ID: 16390584
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.