261 related articles for article (PubMed ID: 17618034)
1. Cardiac arrest with continuous mechanical chest compression during percutaneous coronary intervention. A report on the use of the LUCAS device.
Larsen AI; Hjørnevik AS; Ellingsen CL; Nilsen DW
Resuscitation; 2007 Dec; 75(3):454-9. PubMed ID: 17618034
[TBL] [Abstract][Full Text] [Related]
2. Treatment of out-of-hospital cardiac arrest with LUCAS, a new device for automatic mechanical compression and active decompression resuscitation.
Steen S; Sjöberg T; Olsson P; Young M
Resuscitation; 2005 Oct; 67(1):25-30. PubMed ID: 16159692
[TBL] [Abstract][Full Text] [Related]
3. Cardiac arrest in the catheterisation laboratory: a 5-year experience of using mechanical chest compressions to facilitate PCI during prolonged resuscitation efforts.
Wagner H; Terkelsen CJ; Friberg H; Harnek J; Kern K; Lassen JF; Olivecrona GK
Resuscitation; 2010 Apr; 81(4):383-7. PubMed ID: 20007005
[TBL] [Abstract][Full Text] [Related]
4. A case of hypothermic cardiac arrest treated with an external chest compression device (LUCAS) during transport to re-warming.
Holmström P; Boyd J; Sorsa M; Kuisma M
Resuscitation; 2005 Oct; 67(1):139-41. PubMed ID: 16129539
[TBL] [Abstract][Full Text] [Related]
5. Safety, feasibility, and hemodynamic and blood flow effects of active compression-decompression of thorax and abdomen in patients with cardiac arrest.
Havel C; Berzlanovich A; Sterz F; Domanovits H; Herkner H; Zeiner A; Behringer W; Laggner AN
Crit Care Med; 2008 Jun; 36(6):1832-7. PubMed ID: 18496364
[TBL] [Abstract][Full Text] [Related]
6. [Mechanical cardiac massage].
Christensen PH; Barnung S; Steinmetz J
Ugeskr Laeger; 2009 Aug; 171(35):2463-5. PubMed ID: 19732531
[TBL] [Abstract][Full Text] [Related]
7. Characteristics and outcome among patients suffering from out-of-hospital cardiac arrest with the emphasis on availability for intervention trials.
Axelsson C; Axelsson AB; Svensson L; Herlitz J
Resuscitation; 2007 Dec; 75(3):460-8. PubMed ID: 17767992
[TBL] [Abstract][Full Text] [Related]
8. Compression force-depth relationship during out-of-hospital cardiopulmonary resuscitation.
Tomlinson AE; Nysaether J; Kramer-Johansen J; Steen PA; Dorph E
Resuscitation; 2007 Mar; 72(3):364-70. PubMed ID: 17141936
[TBL] [Abstract][Full Text] [Related]
9. Automated continuous chest compression for in-hospital cardiopulmonary resuscitation of patients with pulseless electrical activity: a report of five cases.
Bonnemeier H; Olivecrona G; Simonis G; Götberg M; Weitz G; Iblher P; Gerling I; Schunkert H
Int J Cardiol; 2009 Aug; 136(2):e39-50. PubMed ID: 18691783
[TBL] [Abstract][Full Text] [Related]
10. Full recovery after prolonged cardiac arrest and resuscitation with mechanical chest compression device during helicopter transportation and percutaneous coronary intervention.
Forti A; Zilio G; Zanatta P; Ferramosca M; Gatto C; Gheno A; Rosi P
J Emerg Med; 2014 Dec; 47(6):632-4. PubMed ID: 25300208
[TBL] [Abstract][Full Text] [Related]
11. Catheterization laboratory activation during mechanical cardiopulmonary resuscitation: when should we say "No?".
Kalra A; Maharaj V; Johannsen RA; Hollenberg SM
Catheter Cardiovasc Interv; 2014 Jan; 83(1):58-64. PubMed ID: 24038710
[TBL] [Abstract][Full Text] [Related]
12. Does compression-only cardiopulmonary resuscitation generate adequate passive ventilation during cardiac arrest?
Deakin CD; O'Neill JF; Tabor T
Resuscitation; 2007 Oct; 75(1):53-9. PubMed ID: 17507138
[TBL] [Abstract][Full Text] [Related]
13. Effects of incomplete chest wall decompression during cardiopulmonary resuscitation on coronary and cerebral perfusion pressures in a porcine model of cardiac arrest.
Yannopoulos D; McKnite S; Aufderheide TP; Sigurdsson G; Pirrallo RG; Benditt D; Lurie KG
Resuscitation; 2005 Mar; 64(3):363-72. PubMed ID: 15733767
[TBL] [Abstract][Full Text] [Related]
14. [Automatic mechanical chest compression during helicopter transportation].
Kyrval HS; Ahmad K
Ugeskr Laeger; 2010 Nov; 172(46):3190-1. PubMed ID: 21073834
[TBL] [Abstract][Full Text] [Related]
15. Tight control of effectiveness of cardiac massage with invasive blood pressure monitoring during cardiopulmonary resuscitation.
Prause G; Archan S; Gemes G; Kaltenböck F; Smolnikov I; Schuchlenz H; Wildner G
Am J Emerg Med; 2010 Jul; 28(6):746.e5-6. PubMed ID: 20637398
[TBL] [Abstract][Full Text] [Related]
16. LUCAS 2™ device, compression depth, and the 2010 cardiopulmonary resuscitation guidelines.
Trivedi K; Borovnik-Lesjak V; Gazmuri RJ
Am J Emerg Med; 2013 Jul; 31(7):1154.e1-2. PubMed ID: 23688566
[TBL] [Abstract][Full Text] [Related]
17. Increased cortical cerebral blood flow with LUCAS; a new device for mechanical chest compressions compared to standard external compressions during experimental cardiopulmonary resuscitation.
Rubertsson S; Karlsten R
Resuscitation; 2005 Jun; 65(3):357-63. PubMed ID: 15919574
[TBL] [Abstract][Full Text] [Related]
18. Coronary blood flow and perfusion pressure during coronary angiography in patients with ongoing mechanical chest compression: a report on 6 cases.
Larsen AI; Hjørnevik A; Bonarjee V; Barvik S; Melberg T; Nilsen DW
Resuscitation; 2010 Apr; 81(4):493-7. PubMed ID: 20227005
[TBL] [Abstract][Full Text] [Related]
19. No difference in autopsy detected injuries in cardiac arrest patients treated with manual chest compressions compared with mechanical compressions with the LUCAS device--a pilot study.
Smekal D; Johansson J; Huzevka T; Rubertsson S
Resuscitation; 2009 Oct; 80(10):1104-7. PubMed ID: 19595496
[TBL] [Abstract][Full Text] [Related]
20. [Prolonged mechanical cardiopulmonary resuscitation].
Greisen J; Golbaekdal KI; Mathiassen ON; Ravn HB
Ugeskr Laeger; 2010 Nov; 172(46):3191-2. PubMed ID: 21073835
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]