BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 17622013)

  • 1. Biomechanics of the mandible: Part II. Development of a 3-dimensional finite element model to study mandibular functional deformation in subjects treated with dental implants.
    Al-Sukhun J; Kelleway J
    Int J Oral Maxillofac Implants; 2007; 22(3):455-66. PubMed ID: 17622013
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanics of the mandible part I: measurement of mandibular functional deformation using custom-fabricated displacement transducers.
    Al-Sukhun J; Helenius M; Lindqvist C; Kelleway J
    J Oral Maxillofac Surg; 2006 Jul; 64(7):1015-22. PubMed ID: 16781333
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Functional mandibular deformation in edentulous subjects treated with dental implants.
    Abdel-Latif HH; Hobkirk JA; Kelleway JP
    Int J Prosthodont; 2000; 13(6):513-9. PubMed ID: 11203678
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of a three-dimensional finite element model of a human mandible containing endosseous dental implants. I. Mathematical validation and experimental verification.
    Al-Sukhun J; Kelleway J; Helenius M
    J Biomed Mater Res A; 2007 Jan; 80(1):234-46. PubMed ID: 17078048
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Midline mandibular deformation during nonmasticatory functional movements in edentulous subjects with dental implants.
    El-Sheikh AM; Abdel-Latif HH; Howell PG; Hobkirk JA
    Int J Oral Maxillofac Implants; 2007; 22(2):243-8. PubMed ID: 17465349
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Experimental and finite element study of a human mandible.
    Vollmer D; Meyer U; Joos U; Vègh A; Piffko J
    J Craniomaxillofac Surg; 2000 Apr; 28(2):91-6. PubMed ID: 10958421
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of tissue-engineered articular disc implants on the biomechanical loading of the human temporomandibular joint in a three-dimensional finite element model.
    Al-Sukhun J; Ashammakhi N; Penttila H
    J Craniofac Surg; 2007 Jul; 18(4):781-8; discussion 789-91. PubMed ID: 17667665
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dental application of novel finite element analysis software for three-dimensional finite element modeling of a dentulous mandible from its computed tomography images.
    Nakamura K; Tajima K; Chen KK; Nagamatsu Y; Kakigawa H; Masumi SI
    Proc Inst Mech Eng H; 2013 Dec; 227(12):1312-8. PubMed ID: 24077258
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Three-dimensional finite element analysis of vertical and angular misfit in implant-supported fixed prostheses.
    Assunção WG; Gomes EA; Rocha EP; Delben JA
    Int J Oral Maxillofac Implants; 2011; 26(4):788-96. PubMed ID: 21841989
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Blast injuries to the human mandible: development of a finite element model and a preliminary finite element analysis.
    Lei T; Xie L; Tu W; Chen Y; Tang Z; Tan Y
    Injury; 2012 Nov; 43(11):1850-5. PubMed ID: 22889532
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Three-dimensional finite element analysis of the effect of 1-piece superstructure on mandibular flexure.
    Naini RB; Nokar S
    Implant Dent; 2009 Oct; 18(5):428-37. PubMed ID: 22129961
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical evaluation of mandibular midline distraction osteogenesis by using the finite element method.
    Basciftci FA; Korkmaz HH; Işeri H; Malkoç S
    Am J Orthod Dentofacial Orthop; 2004 Jun; 125(6):706-15. PubMed ID: 15179395
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical rationale for intentionally inclined implants in the posterior mandible using 3D finite element analysis.
    Satoh T; Maeda Y; Komiyama Y
    Int J Oral Maxillofac Implants; 2005; 20(4):533-9. PubMed ID: 16161737
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Three-dimensional finite element stress analysis of a cuneiform-geometry implant.
    Cruz M; Wassall T; Toledo EM; Barra LP; Lemonge AC
    Int J Oral Maxillofac Implants; 2003; 18(5):675-84. PubMed ID: 14579955
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparative 3D finite element stress analysis of straight and angled wedge-shaped implant designs.
    Las Casas EB; Ferreira PC; Cimini CA; Toledo EM; Barra LP; Cruz M
    Int J Oral Maxillofac Implants; 2008; 23(2):215-25. PubMed ID: 18548917
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tilted or parallel implant placement in the completely edentulous mandible? A three-dimensional finite element analysis.
    Naini RB; Nokar S; Borghei H; Alikhasi M
    Int J Oral Maxillofac Implants; 2011; 26(4):776-81. PubMed ID: 21841987
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone.
    Sütpideler M; Eckert SE; Zobitz M; An KN
    Int J Oral Maxillofac Implants; 2004; 19(6):819-25. PubMed ID: 15623056
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Morphologic classification and stress analysis of the mandibular bone in the premolar region for implant placement.
    Hudieb M; Wakabayashi N; Suzuki T; Kasugai S
    Int J Oral Maxillofac Implants; 2010; 25(3):482-90. PubMed ID: 20556246
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Finite-element analysis of 3 situations of trauma in the human edentulous mandible.
    Santos LS; Rossi AC; Freire AR; Matoso RI; Caria PH; Prado FB
    J Oral Maxillofac Surg; 2015 Apr; 73(4):683-91. PubMed ID: 25577458
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of a three-dimensional finite element model of a human mandible containing endosseous dental implants. II. Variables affecting the predictive behavior of a finite element model of a human mandible.
    Al-Sukhun J; Lindqvist C; Helenius M
    J Biomed Mater Res A; 2007 Jan; 80(1):247-56. PubMed ID: 17078047
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.