BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 17635201)

  • 21. Toward Neuro-Oncologic Clinical Trials of High-Dose-Rate Synchrotron Microbeam Radiation Therapy: First Treatment of a Spontaneous Canine Brain Tumor.
    Adam JF; Balosso J; Bayat S; Berkvens P; Berruyer G; Bräuer-Krisch E; Brochard T; Chamel G; Desagneaux A; Drevon-Gaud R; Eling L; Estève F; Flandin I; Gaudin M; Giraud JY; Giraud L; Gonzalez H; Kefs S; Keshmiri S; Krainik A; Krisch M; Laissue JA; Lemaire G; Mauro A; Nemoz C; Pellicioli P; Renier M; Verry C; Serduc R
    Int J Radiat Oncol Biol Phys; 2022 Aug; 113(5):967-973. PubMed ID: 35483539
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Response of the rat spinal cord to X-ray microbeams.
    Laissue JA; Bartzsch S; Blattmann H; Bräuer-Krisch E; Bravin A; Dalléry D; Djonov V; Hanson AL; Hopewell JW; Kaser-Hotz B; Keyriläinen J; Laissue PP; Miura M; Serduc R; Siegbahn AE; Slatkin DN
    Radiother Oncol; 2013 Jan; 106(1):106-11. PubMed ID: 23321495
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Treating Brain Tumor with Microbeam Radiation Generated by a Compact Carbon-Nanotube-Based Irradiator: Initial Radiation Efficacy Study.
    Yuan H; Zhang L; Frank JE; Inscoe CR; Burk LM; Hadsell M; Lee YZ; Lu J; Chang S; Zhou O
    Radiat Res; 2015 Sep; 184(3):322-33. PubMed ID: 26305294
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Radiobiological features of the anti-cancer strategies involving synchrotron X-rays.
    Bencokova Z; Balosso J; Foray N
    J Synchrotron Radiat; 2008 Jan; 15(Pt 1):74-85. PubMed ID: 18097081
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Synchrotron-generated microbeam radiosurgery: a novel experimental approach to modulate brain function.
    Romanelli P; Bravin A
    Neurol Res; 2011 Oct; 33(8):825-31. PubMed ID: 22004705
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Synchrotron X-Ray Boost Delivered by Microbeam Radiation Therapy After Conventional X-Ray Therapy Fractionated in Time Improves F98 Glioma Control.
    Potez M; Bouchet A; Flaender M; Rome C; Collomb N; Grotzer M; Krisch M; Djonov V; Balosso J; Brun E; Laissue JA; Serduc R
    Int J Radiat Oncol Biol Phys; 2020 Jun; 107(2):360-369. PubMed ID: 32088292
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Improved normal tissue protection by proton and X-ray microchannels compared to homogeneous field irradiation.
    Girst S; Marx C; Bräuer-Krisch E; Bravin A; Bartzsch S; Oelfke U; Greubel C; Reindl J; Siebenwirth C; Zlobinskaya O; Multhoff G; Dollinger G; Schmid TE; Wilkens JJ
    Phys Med; 2015 Sep; 31(6):615-20. PubMed ID: 25936621
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Identification of AREG and PLK1 pathway modulation as a potential key of the response of intracranial 9L tumor to microbeam radiation therapy.
    Bouchet A; Sakakini N; Atifi ME; Le Clec'h C; Bräuer-Krisch E; Rogalev L; Laissue JA; Rihet P; Le Duc G; Pelletier L
    Int J Cancer; 2015 Jun; 136(11):2705-16. PubMed ID: 25382544
    [TBL] [Abstract][Full Text] [Related]  

  • 29. New technology enables high precision multislit collimators for microbeam radiation therapy.
    Bräuer-Krisch E; Requardt H; Brochard T; Berruyer G; Renier M; Laissue JA; Bravin A
    Rev Sci Instrum; 2009 Jul; 80(7):074301. PubMed ID: 19655968
    [TBL] [Abstract][Full Text] [Related]  

  • 30. X-Tream quality assurance in synchrotron X-ray microbeam radiation therapy.
    Fournier P; Cornelius I; Donzelli M; Requardt H; Nemoz C; Petasecca M; Bräuer-Krisch E; Rosenfeld A; Lerch M
    J Synchrotron Radiat; 2016 Sep; 23(Pt 5):1180-90. PubMed ID: 27577773
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Absorbed dose-to-water protocol applied to synchrotron-generated x-rays at very high dose rates.
    Fournier P; Crosbie JC; Cornelius I; Berkvens P; Donzelli M; Clavel AH; Rosenfeld AB; Petasecca M; Lerch ML; Bräuer-Krisch E
    Phys Med Biol; 2016 Jul; 61(14):N349-61. PubMed ID: 27366861
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Optimizing dose enhancement with Ta
    Engels E; Corde S; McKinnon S; Incerti S; Konstantinov K; Rosenfeld A; Tehei M; Lerch M; Guatelli S
    Phys Med; 2016 Dec; 32(12):1852-1861. PubMed ID: 27866898
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Radiosurgical palliation of aggressive murine SCCVII squamous cell carcinomas using synchrotron-generated X-ray microbeams.
    Miura M; Blattmann H; Bräuer-Krisch E; Bravin A; Hanson AL; Nawrocky MM; Micca PL; Slatkin DN; Laissue JA
    Br J Radiol; 2006 Jan; 79(937):71-5. PubMed ID: 16421408
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A new method of creating minibeam patterns for synchrotron radiation therapy: a feasibility study.
    Prezado Y; Renier M; Bravin A
    J Synchrotron Radiat; 2009 Jul; 16(Pt 4):582-6. PubMed ID: 19535874
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effect of acidic environment on the response of endothelial cells to irradiation: implications for microbeam radiation therapy.
    Kim SR; Kim EH
    Int J Radiat Biol; 2014 Apr; 90(4):325-33. PubMed ID: 24467329
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Prospects for microbeam radiation therapy of brain tumours in children.
    Slatkin DN; Blattmann H; Wagner HP; Glotzer MA; Laissue JA
    Dev Med Child Neurol; 2009 Feb; 51(2):163. PubMed ID: 19018844
    [No Abstract]   [Full Text] [Related]  

  • 37. Sparing of tissue by using micro-slit-beam radiation therapy reduces neurotoxicity compared with broad-beam radiation therapy.
    Mukumoto N; Nakayama M; Akasaka H; Shimizu Y; Osuga S; Miyawaki D; Yoshida K; Ejima Y; Miura Y; Umetani K; Kondoh T; Sasaki R
    J Radiat Res; 2017 Jan; 58(1):17-23. PubMed ID: 27422939
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Microradiosurgical cortical transections generated by synchrotron radiation.
    Romanelli P; Fardone E; Bucci D; Battaglia G; Bräuer-Krisch E; Requardt H; Le Duc G; Bravin A
    Phys Med; 2015 Sep; 31(6):642-6. PubMed ID: 26032004
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Irradiation of intracerebral 9L gliosarcoma by a single array of microplanar x-ray beams from a synchrotron: balance between curing and sparing.
    Regnard P; Le Duc G; Bräuer-Krisch E; Troprès I; Siegbahn EA; Kusak A; Clair C; Bernard H; Dallery D; Laissue JA; Bravin A
    Phys Med Biol; 2008 Feb; 53(4):861-78. PubMed ID: 18263945
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Tolerance of arteries to microplanar X-ray beams.
    van der Sanden B; Bräuer-Krisch E; Siegbahn EA; Ricard C; Vial JC; Laissue J
    Int J Radiat Oncol Biol Phys; 2010 Aug; 77(5):1545-52. PubMed ID: 20646873
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.