These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 1763587)

  • 61. Intraoperative determination of cardiac output by transesophageal continuous wave Doppler.
    Gorcsan J; Diana P; Ball BA; Hattler BG
    Am Heart J; 1992 Jan; 123(1):171-6. PubMed ID: 1729822
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Mitral stenosis with unusual atrial shunt diagnosed by biplane transesophageal Doppler echocardiography.
    Okamoto M; Tsubokura T; Kawagoe T; Karakawa S; Morichika N; Yamagata T; Tsuchioka Y; Matsuura H; Kajiyama G
    Am Heart J; 1991 Nov; 122(5):1498-501. PubMed ID: 1951027
    [No Abstract]   [Full Text] [Related]  

  • 63. Transoesophageal echocardiography--widening the scope.
    Crowley JJ; Maurer BJ
    Ir Med J; 1992 Jun; 85(2):44-6. PubMed ID: 1628937
    [No Abstract]   [Full Text] [Related]  

  • 64. Intraoperative Diagnosis of Intracardiac Thrombus During Orthotopic Liver Transplantation With Transesophageal Echocardiography: A Case Series and Literature Review.
    Dalia AA; Khan H; Flores AS
    Semin Cardiothorac Vasc Anesth; 2017 Sep; 21(3):245-251. PubMed ID: 27837084
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Usefulness and limitations of transesophageal echocardiography in the assessment of proximal coronary artery stenosis.
    Samdarshi TE; Nanda NC; Gatewood RP; Ballal RS; Chang LK; Singh HP; Nath H; Kirklin JK; Pacifico AD
    J Am Coll Cardiol; 1992 Mar; 19(3):572-80. PubMed ID: 1538012
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Intraoperative validation of mitral inflow determination by transesophageal echocardiography: comparison of single-plane, biplane and thermodilution techniques.
    Pu M; Griffin BP; Vandervoort PM; Leung DY; Cosgrove DM; Thomas JD
    J Am Coll Cardiol; 1995 Oct; 26(4):1047-53. PubMed ID: 7560598
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Cardiac output monitoring by echocardiography: should we pass on Swan-Ganz catheters?
    Perrino AC
    Yale J Biol Med; 1993; 66(5):397-413. PubMed ID: 7825341
    [TBL] [Abstract][Full Text] [Related]  

  • 68. The utility of transesophageal echocardiography and Doppler color flow imaging in patients undergoing cardiac valve surgery.
    Sheikh KH; de Bruijn NP; Rankin JS; Clements FM; Stanley T; Wolfe WG; Kisslo J
    J Am Coll Cardiol; 1990 Feb; 15(2):363-72. PubMed ID: 2299078
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Innovation, NICE, and CardioQ.
    Campbell B
    Br J Anaesth; 2012 May; 108(5):726-9. PubMed ID: 22499745
    [No Abstract]   [Full Text] [Related]  

  • 70. [Transesophageal echocardiography: principles, technique and potential indications in veterinary medicine].
    Chetboul V; Pouchelon JL
    Schweiz Arch Tierheilkd; 2004 Jul; 146(7):321-6. PubMed ID: 15323406
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Cardiac output in 1998.
    Singer M
    Heart; 1998 May; 79(5):425-8. PubMed ID: 9659184
    [No Abstract]   [Full Text] [Related]  

  • 72. Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting.
    Missant C; Rex S; Wouters PF
    Eur J Anaesthesiol; 2008 Mar; 25(3):243-8. PubMed ID: 17996125
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Coronary artery fistula: diagnosis by transesophageal two-dimensional and Doppler echocardiography.
    Kuo CT; Chiang CW; Fang BR; Lee CP; Hsu TS; Lee YS; Chang CH
    Am Heart J; 1992 Jan; 123(1):218-20. PubMed ID: 1729829
    [No Abstract]   [Full Text] [Related]  

  • 74. [Transesophageal echocardiography].
    Sparacino L; Nicolosi GL; Zanuttini D
    G Ital Cardiol; 1988 Sep; 18(9):748-52. PubMed ID: 3069540
    [No Abstract]   [Full Text] [Related]  

  • 75. Transesophageal echocardiography: clinical applications and prospects.
    Roelandt JR; Fraser AG
    Curr Opin Cardiol; 1990 Dec; 5(6):783-94. PubMed ID: 10171137
    [No Abstract]   [Full Text] [Related]  

  • 76. Noninvasive cardiac output monitors: a state-of the-art review.
    Marik PE
    J Cardiothorac Vasc Anesth; 2013 Feb; 27(1):121-34. PubMed ID: 22609340
    [No Abstract]   [Full Text] [Related]  

  • 77. [The "flickering" phenomenon in the right atrium].
    Onishchenko EF; Loĭt AA; Il'in AS
    Ter Arkh; 1993; 65(4):35-40. PubMed ID: 8059405
    [TBL] [Abstract][Full Text] [Related]  

  • 78. "Nonanatomic" correlations of transesophageal echocardiography.
    Seward JB
    Echocardiography; 1991 Nov; 8(6):669-70. PubMed ID: 10149278
    [No Abstract]   [Full Text] [Related]  

  • 79. Midesophageal Short-Axis Views of the Pulmonary Valve With Conventional 2-Dimensional Transesophageal Echocardiography: A Useful View in Pediatric Patients.
    Shriram Lovhale P; Misra S; Koshy T
    J Cardiothorac Vasc Anesth; 2017 Apr; 31(2):e36-e38. PubMed ID: 28153455
    [No Abstract]   [Full Text] [Related]  

  • 80. [Thrombosis of atrioventricular prosthesis. Contribution of transesophageal echocardiography].
    Bournazel V; Diebold B; Laperche T; Abergel E; Raffoul H; Habert C; Cohen A; Rinaldi JP; Peronneau P
    Arch Mal Coeur Vaiss; 1991 Nov; 84(11):1543-8. PubMed ID: 1763920
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.