BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

345 related articles for article (PubMed ID: 17638713)

  • 1. Numerical investigation of turbulent diffusion in push-pull and exhaust fume cupboards.
    Chern MJ; Cheng WY
    Ann Occup Hyg; 2007 Aug; 51(6):517-31. PubMed ID: 17638713
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Airborne nanoparticle exposures while using constant-flow, constant-velocity, and air-curtain-isolated fume hoods.
    Tsai SJ; Huang RF; Ellenbecker MJ
    Ann Occup Hyg; 2010 Jan; 54(1):78-87. PubMed ID: 19933309
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Numerical investigation and recommendations for push-pull ventilation systems.
    Chern MJ; Ma CH
    J Occup Environ Hyg; 2007 Mar; 4(3):184-97. PubMed ID: 17237024
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of a push-pull ventilation system to control solder fume.
    Watson SI; Cain JR; Cowie H; Cherrie JW
    Ann Occup Hyg; 2001 Nov; 45(8):669-76. PubMed ID: 11718662
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development and evaluation of an air-curtain fume cabinet with considerations of its aerodynamics.
    Huang RF; Wu YD; Chen HD; Chen CC; Chen CW; Chang CP; Shih TS
    Ann Occup Hyg; 2007 Mar; 51(2):189-206. PubMed ID: 16857702
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of doorsill jet injection on fume cupboard containment.
    Tseng LC; Huang RF; Chen CC
    Ann Occup Hyg; 2008 Oct; 52(7):635-44. PubMed ID: 18660505
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Numerical simulation of airflow around a variable volume/constant face velocity fume cupboard.
    Lan NS; Viswanathan S
    AIHAJ; 2001; 62(3):303-12. PubMed ID: 11434436
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Flow and leakage characteristics of a sashless inclined air-curtain (sIAC) fume hood containing tall pollutant-generation tanks.
    Chen JK; Huang RF; Hung WL
    J Occup Environ Hyg; 2013; 10(12):694-704. PubMed ID: 24195536
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Flow and containment characteristics of a sash-less, variable-height inclined air-curtain fume hood.
    Huang RF; Chen JK; Hung WL
    Ann Occup Hyg; 2013 Aug; 57(7):934-52. PubMed ID: 23519947
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of sash movement and walk-bys on aerodynamics and contaminant leakage of laboratory fume cupboards.
    Tseng LC; Huang RF; Chen CC; Chang CP
    Ind Health; 2007 Apr; 45(2):199-208. PubMed ID: 17485863
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of baffles and a louvered bypass on the airflow and the convective patterns of contaminant inside a fume hood.
    Hu P; Ingham DB; Wen X
    Am Ind Hyg Assoc J; 1998 May; 59(5):303-12. PubMed ID: 9858973
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Required response time for variable air volume fume hood controllers.
    Ekberg LE; Melin J
    Ann Occup Hyg; 2000 Mar; 44(2):143-50. PubMed ID: 10717266
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Aerodynamic characteristics and design guidelines of push-pull ventilation systems.
    Huang RF; Lin SY; Jan SY; Hsieh RH; Chen YK; Chen CW; Yeh WY; Chang CP; Shih TS; Chen CC
    Ann Occup Hyg; 2005 Jan; 49(1):1-15. PubMed ID: 15591077
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Aerodynamics and performance verifications of test methods for laboratory fume cupboards.
    Tseng LC; Huang RF; Chen CC; Chang CP
    Ann Occup Hyg; 2007 Mar; 51(2):173-87. PubMed ID: 16921195
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A review of published quantitative experimental studies on factors affecting laboratory fume hood performance.
    Ahn K; Woskie S; DiBerardinis L; Ellenbecker M
    J Occup Environ Hyg; 2008 Nov; 5(11):735-53. PubMed ID: 18780237
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Installation of a flow control device in an inclined air-curtain fume hood to control wake-induced exposure.
    Chen JK
    J Occup Environ Hyg; 2016 Aug; 13(8):588-97. PubMed ID: 26950527
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development and characterization of an inclined air-curtain (IAC) fume hood.
    Huang RF; Chen JK; Tang KC
    Ann Occup Hyg; 2015 Jun; 59(5):655-67. PubMed ID: 25690760
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A simple method for fume cupboard performance assessment.
    Nicholson GP; Clark RP; Grover F; de Calcina-Goff ML
    Ann Occup Hyg; 2000 Jun; 44(4):291-300. PubMed ID: 10831733
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improving flow and spillage characteristics of range hoods by using an inclined air-curtain technique.
    Huang RF; Nian YC; Chen JK; Peng KL
    Ann Occup Hyg; 2011 Mar; 55(2):164-79. PubMed ID: 21071606
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Computational fluid dynamics as a method for assessing fume cupboard performance.
    Nicholson GP; Clark RP; de Calcina-Goff ML
    Ann Occup Hyg; 2000 May; 44(3):203-17. PubMed ID: 10775669
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]