These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
85 related articles for article (PubMed ID: 17644252)
1. Comparative study of different process steps for the near-field optical probes manufacturing. Chaigneau M; Minea T; Louarn G Ultramicroscopy; 2007 Oct; 107(10-11):1042-7. PubMed ID: 17644252 [TBL] [Abstract][Full Text] [Related]
2. Coupling efficiency of probes in emission-mode scanning near-field optical microscopy. Alvarez L; Xiao M J Microsc; 2008 Feb; 229(Pt 2):371-6. PubMed ID: 18304099 [TBL] [Abstract][Full Text] [Related]
3. Focussed ion beam machined cantilever aperture probes for near-field optical imaging. Jin EX; Xu X J Microsc; 2008 Mar; 229(Pt 3):503-11. PubMed ID: 18331502 [TBL] [Abstract][Full Text] [Related]
5. Bowtie nano-aperture as interface between near-fields and a single-mode fiber. Mivelle M; Ibrahim IA; Baida F; Burr GW; Nedeljkovic D; Charraut D; Rauch JY; Salut R; Grosjean T Opt Express; 2010 Jul; 18(15):15964-74. PubMed ID: 20720980 [TBL] [Abstract][Full Text] [Related]
6. Vibration sensitivity of the scanning near-field optical microscope with a tapered optical fiber probe. Chang WJ; Fang TH; Lee HL; Yang YC Ultramicroscopy; 2005 Jan; 102(2):85-92. PubMed ID: 15590131 [TBL] [Abstract][Full Text] [Related]
7. Scanning probe microscopies applied to the study of the domain wall in a ferroelectric crystal. Canet-Ferrer J; Martín-Carrón L; Martínez-Pastor J; Valdés JL; Peña A; Carvajal JJ; Diaz F J Microsc; 2007 May; 226(Pt 2):133-9. PubMed ID: 17444942 [TBL] [Abstract][Full Text] [Related]
8. Hollow-pyramid based scanning near-field optical microscope coupled to femtosecond pulses: a tool for nonlinear optics at the nanoscale. Celebrano M; Biagioni P; Zavelani-Rossi M; Polli D; Labardi M; Allegrini M; Finazzi M; Duò L; Cerullo G Rev Sci Instrum; 2009 Mar; 80(3):033704. PubMed ID: 19334924 [TBL] [Abstract][Full Text] [Related]
14. Comparative study of the effective single mode operational bandwidth in sub-wavelength optical wires and conventional single-mode fibers. Jung Y; Brambilla G; Richardson DJ Opt Express; 2009 Sep; 17(19):16619-24. PubMed ID: 19770877 [TBL] [Abstract][Full Text] [Related]
15. Some aspects of the silicon behaviour under femtosecond pulsed laser field evaporation. Gilbert M; Vurpillot F; Vella A; Bernas H; Deconihout B Ultramicroscopy; 2007 Sep; 107(9):767-72. PubMed ID: 17399901 [TBL] [Abstract][Full Text] [Related]
16. Resolution enhancing using cantilevered tip-on-aperture silicon probe in scanning near-field optical microscopy. Chang WS; Bauerdick S; Jeong MS Ultramicroscopy; 2008 Sep; 108(10):1070-5. PubMed ID: 18579310 [TBL] [Abstract][Full Text] [Related]