1133 related articles for article (PubMed ID: 17654914)
1. Optically stimulated luminescence (OSL) of carbon-doped aluminum oxide (Al2O3:C) for film dosimetry in radiotherapy.
Schembri V; Heijmen BJ
Med Phys; 2007 Jun; 34(6):2113-8. PubMed ID: 17654914
[TBL] [Abstract][Full Text] [Related]
2. Characterization of Al
Ahmed MF; Shrestha N; Schnell E; Ahmad S; Akselrod MS; Yukihara EG
Phys Med Biol; 2016 Nov; 61(21):7551-7570. PubMed ID: 27716632
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of Al2O3:C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy.
Yukihara EG; Mardirossian G; Mirzasadeghi M; Guduru S; Ahmad S
Med Phys; 2008 Jan; 35(1):260-9. PubMed ID: 18293581
[TBL] [Abstract][Full Text] [Related]
4. A reusable OSL-film for 2D radiotherapy dosimetry.
Wouter C; Dirk V; Paul L; Tom D
Phys Med Biol; 2017 Oct; 62(21):8441-8454. PubMed ID: 29047456
[TBL] [Abstract][Full Text] [Related]
5. Radiotherapy dosimetry using a commercial OSL system.
Viamonte A; da Rosa LA; Buckley LA; Cherpak A; Cygler JE
Med Phys; 2008 Apr; 35(4):1261-6. PubMed ID: 18491518
[TBL] [Abstract][Full Text] [Related]
6. Influence of phantom material and phantom size on radiographic film response in therapy photon beams.
Palm A; LoSasso T
Med Phys; 2005 Aug; 32(8):2434-42. PubMed ID: 16193772
[TBL] [Abstract][Full Text] [Related]
7. High-precision dosimetry for radiotherapy using the optically stimulated luminescence technique and thin Al2O3:C dosimeters.
Yukihara EG; Yoshimura EM; Lindstrom TD; Ahmad S; Taylor KK; Mardirossian G
Phys Med Biol; 2005 Dec; 50(23):5619-28. PubMed ID: 16306656
[TBL] [Abstract][Full Text] [Related]
8. Image reconstruction algorithm for optically stimulated luminescence 2D dosimetry using laser-scanned Al
Ahmed MF; Schnell E; Ahmad S; Yukihara EG
Phys Med Biol; 2016 Oct; 61(20):7484-7506. PubMed ID: 27694704
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of GAFCHROMIC EBT film for Cyberknife dosimetry.
Wilcox EE; Daskalov GM
Med Phys; 2007 Jun; 34(6):1967-74. PubMed ID: 17654899
[TBL] [Abstract][Full Text] [Related]
10. Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams.
Brown TA; Hogstrom KR; Alvarez D; Matthews KL; Ham K; Dugas JP
Med Phys; 2012 Dec; 39(12):7412-7. PubMed ID: 23231291
[TBL] [Abstract][Full Text] [Related]
11. EBT GAFCHROMIC(TM) film dosimetry in compensator-based intensity modulated radiation therapy.
Vaezzadeh S; Allahverdi M; Nedaie HA; Ay M; Shirazi A; Yarahmadi M
Med Dosim; 2013; 38(2):176-83. PubMed ID: 23290715
[TBL] [Abstract][Full Text] [Related]
12. Near-real-time radiotherapy dosimetry using optically stimulated luminescence of Al2O3:C: mathematical models and preliminary results.
Gaza R; McKeever SW; Akselrod MS
Med Phys; 2005 Apr; 32(4):1094-102. PubMed ID: 15895594
[TBL] [Abstract][Full Text] [Related]
13. Comparative evaluation of Kodak EDR2 and XV2 films for verification of intensity modulated radiation therapy.
Dogan N; Leybovich LB; Sethi A
Phys Med Biol; 2002 Nov; 47(22):4121-30. PubMed ID: 12476986
[TBL] [Abstract][Full Text] [Related]
14. The energy dependence and dose response of a commercial optically stimulated luminescent detector for kilovoltage photon, megavoltage photon, and electron, proton, and carbon beams.
Reft CS
Med Phys; 2009 May; 36(5):1690-9. PubMed ID: 19544786
[TBL] [Abstract][Full Text] [Related]
15. Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributions.
Dempsey JF; Low DA; Mutic S; Markman J; Kirov AS; Nussbaum GH; Williamson JF
Med Phys; 2000 Oct; 27(10):2462-75. PubMed ID: 11099217
[TBL] [Abstract][Full Text] [Related]
16. Optically stimulated luminescence (OSL) response of Al2O3:C, BaFCl:Eu and K2Ca2(SO4)3:Eu phosphors.
Kumar P; Bahl S; Sahare PD; Kumar S; Singh M
Radiat Prot Dosimetry; 2015 Dec; 167(4):453-60. PubMed ID: 25646524
[TBL] [Abstract][Full Text] [Related]
17. Multi-institutional dose audit in radiotherapy facilities using in-house developed optically stimulated luminescence disc dosimeters.
Kumar P; Sharma SD; Dhabekar B; Rawat NS; Mishra DR; Chaudhari S; Chandola RM; Routh T; Agrawal S
J Cancer Res Ther; 2023 Apr; 19(Supplement):S0. PubMed ID: 37147959
[TBL] [Abstract][Full Text] [Related]
18. New optically stimulated luminescence dosimetry film optimized for energy dependence guided by Monte Carlo simulations.
De Saint-Hubert M; Caprioli M; de Freitas Nascimento L; Delombaerde L; Himschoot K; Vandenbroucke D; Leblans P; Crijns W
Phys Med Biol; 2024 Mar; 69(7):. PubMed ID: 38394683
[TBL] [Abstract][Full Text] [Related]
19. Monte Carlo evaluations of the absorbed dose and quality dependence of AL2O3 in radiotherapy photon beams.
Chen SW; Wang XT; Chen LX; Tang Q; Liu XW
Med Phys; 2009 Oct; 36(10):4421-4. PubMed ID: 19928072
[TBL] [Abstract][Full Text] [Related]
20. Investigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry.
Chetty IJ; Charland PM
Phys Med Biol; 2002 Oct; 47(20):3629-41. PubMed ID: 12433124
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]